Product Approval Menu > Product or Application Search > -Application List > Application Detail
FL #
FL14317-R10
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Boral Roofing
Address/Phone/Email 7575 Irvine Center Drive
Suite 100
Irvine, CA 92618
(801)380-6091
RobinAnderson@boral.com
Authorized Signature Thomas Jemmett
thomas.jemmett@boral.com
Technical Representative Adrian Cooper
Address/Phone/Email 135 NW 20th Street
Boca Raton, FL 33431
(954)520-5461
acoopeer@minierlifetile.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE -59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/21/2020
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL14317 R10 COI 2018 01 COI NIEMINEN pdf
Standard
ASTM D1970
FRSA/TRI (April 2012) 04-12
UL 1897
Year
2015
2012
2012
https://www.floridabuilding.org/pr/pr app dtI.aspx?param=wGEVXQwtDgsbCUITKe]20BoXpSjktfpju5SjCf9NBzdO24Blg6rhfA%3d%3d 1/2
3/11/2020 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
10/12/2018
Date Validated
10/15/2018
Date Pending FBC Approval
10/22/2018
Date Approved
12/11/2018
Summary of Products
1
FL # Model, Number or Name
Description
14317.1 _AB oral Roof Underlayments
Roof underlayments for use in prepared roof assemblies
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14317 R10 II 2018 10 FINAL ER BORAL Underlayments FL14317-
Approved for use outside HVHZ: Yes
R10.pdf
Impact Resistant: N/A
Verified By: Robert 1. M. Nieminen PE - 59166
Design Pressure: +N/A/ -210
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this application
Evaluation Reports
pertains to a particular underlayment system for use
FL14317 R10 AE 2018 10 FINAL ER BORAL Underlayments FL14317-
under foam -on tile systems. Refer to ER Section
R10.pdf
5.6.4. 2.) Refer to ER Section 5 for Limits of Use.
Created by Independent Third Party: Yes
�I
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy tatement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
LML��M ICE ® R WE
Credit Carte
Sala
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsbC U ITKel2OBoXpSjktfpju5SjCfgN BzdO24B 1 g6rhfA%3d%3d 2/2
NEORECta.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Boral Roofing Evaluation Report M35710.12.10 -R11
7575 Irvine Center Drive, Suite 100 FL14317-R10
Irvine, CA. 92618 Date of Issuance: 12/21/2010
(602) 269-2288 Revision 11: 10/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 611 Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates,
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
''` :''� ' `•`
a,,�s` .•, ;,,.
The facsimile seal appearing y
ppearin was authorized b Robert
Nieminen, P.E. on 10/12/2018. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEW ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates,
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOJetc.
ROOFING COMPONENT EVALUATION:
SCOPE:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Boral Roof Underlayments,
as marketed by Boral Roofing,
have demonstrated
compliance with the following
sections of the 6t" Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, T1507.1.1,
Physical Properties
ASTM D1970
2015
1507.2.9.2
1507.3.3
3.
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
REFERENCES:
Entity
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
M36790.07.11
09/30/2011
ERD (TST 6049)
Physical Properties
B40380.08.12
08/28/2012
ERD (TST 6049)
Tensile Adhesion / LTA
C41420.09.12-2
09/11/2012
ERD (TST 6049)
Adhesion
B41940.09.12
09/13/2012
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.07.14-1
07/31/2014
ERD (TST 6049)
Tensile Adhesion / LTA
647390.09.14
09/04/2014
OC (PDM1838)
Physical Properties
Equivalency statement
11/02/2017
PRI (TST 5878)
ASTM D1970
NEI-031-02-02:REV
10/27/2010
PRI (TST 5878)
ASTM D1970
NEI-029-02-01:REV
12/03/2010
PRI (TST 5878)
Tensile Adhesion / LTA
NEI-046-02-01REV
12/17/2010
PRI (TST 5878)
FRSA/TRI April 2012
NEI -076-02-01
02/14/2011
PRI (TST 5878)
ASTM D1970
NEI -034-02-02
01/29/2013
PRI (TST 5878)
Wind Uplift
BORR-001-02-01
03/17/2015
PRI (TST 5878)
Wind Uplift
BORR-005-02-01
06/24/2015
PRI (TST 5878)
Tensile Adhesion / LTA
DAPF-002-02-01
03/08/2018
PRI (TST 5878)
ASTM D1970 (adhesion)
OCF-443-02-01
10/11/2018
UL, LLC. (QUA 9625)
Quality Assurance
Service Confirmation
Exp. 08/21/2020
4.1 Boral® TileSeal 50"T is a nominal 50 -mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.2 Boral® TileSeal"T is a nominal 60 -mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.3 Boral® MetalSeal"T is a nominal 60 -mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.4 GatorSeal® is a nominal 55 -mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5 Citadel® Plus is a nominal 48 -mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970.
NEMO ETC, LLC Evaluation Report M35710.12.10 -R11
Certificate ofAuthorization#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 2 of 8
ONEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / LINDERLAYMENT COMBINATIONS
I
TABLE 1:
ROOF COVER OPTIONS
Approval
DAP Foam Touch `n Seal StormBond Roof Tile Adhesive
Underlayment
Asphalt
Nail -On Tile
Adhesive -set
Metal
Wood Shakes
Slate
Boral TileSeal"Tor Boral MetalSealHT
Shingles
FL22525
Tile
ICP Adhesives Polyset' AH -160
& Shingles
Boral TileSealHT or Boral MetalSealHT
Boral TileSeal 50HT
Yes
No
No
Yes
Yes
Yes
Boral TileSealHT
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.1)
Boral MetalSealHT
Yes
Yes
Yes
Yes
Yes
Yes
(see 5.5.1)
GatorSeal
Yes
No
No
No
Yes
Yes
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / LINDERLAYMENT COMBINATIONS
I
Adhesive Florida Product
Underlayments
Approval
DAP Foam Touch `n Seal StormBond Roof Tile Adhesive
FL14506
Boral TileSeal"T or Boral MetalSealHT
DAP Foam Touch 'n Seal Storm Bond 2 Two -Component
Polyurethane Roof Tile Adhesive
FL21374
Boral TileSeal"Tor Boral MetalSealHT
Dow TILE BOND'" Roof Tile Adhesive
FL22525
Boral TileSealHT or Boral MetalSealHT
ICP Adhesives Polyset' AH -160
FL6332
Boral TileSealHT or Boral MetalSealHT
ICP Adhesives Polyset® RTA -1
FL6276
Boral TileSeal"T or Boral MetalSealHT
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report M35710.12.10-1111
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 3 of 8
ONEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct-Bond to Deck:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T, Boral MetalSealHT or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSeal"T or Boral MetalSeal"T:
➢ OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the
overlying roof cover is adhesive-set the roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeal", Boral MetalSeal"T or GatorSeal:
➢ ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive-set tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeaJIT , Boral MetalSeal"T or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.).
Boral TileSealIT:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure = -120.0 post:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal IT or Boral MetalSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#2 Maximum Design Pressure = -142.5 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T, self -adhered and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
NEMO ETC, LLC Evaluation Repert IVIM10.12.10-1111
Certificate afAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 4 of 8
ONEMOletc.
#3 Maximum Design Pressure = -202.5 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#4 Maximum Design Pressure = -210.0 psf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer; KARNAK #89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#5 Maximum Design Pressure = -120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T, self -adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longer than 30 -days after installation, prior to placement of final roof cover.
Boral TileSeal 50"T, Boral TileSeal"T or Boral MetalSeal"T shall not be left exposed for longer than 180 -days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
180 -days after installation, prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations IFRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
6. INSTALLATION:
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising.
NEMO ETC, LLC Evaluation Report M35710.12.10 -R11
Certificate ofAuthorization ##32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 5 of 8
ONEMOletc.
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid-layer in multi-ply underlayment systems beneath Boral TileSeal 50"r
Boral TileSeal"T or GatorSeal.
6.4.2 Slope limitations are those associated with the top-layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1 -inch
diameter plastic or steel cap nails spaced maximum 12 -inch o.c. Overlap successive courses the entire width of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"T, Boral
TileSeaJIT , Boral MetalSeal"T or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"T, Boral
TileSeal"T or GatorSeal.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 Boral TileSeal 50"T:
6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"T on roof pitches less than 2:12.
6.5.3 Non -Tile Applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1 -inch diameter
plastic or steel cap nails spaced maximum 24 -inch o.c. for slopes below 7:12 and maximum 12 -inch o.c. for slopes
7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3 -inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.12.10-1111
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 6 of 8
ONEMOjetc.
6.5.4 Non-Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 501T in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self-adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non-Tile applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin-tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the black-selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self-adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications. to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.7 Boral TileSeal"T or Boral MetalSeal"T:
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeal"T or Boral MetalSeal"T on roof pitches less than 2:12.
6.7.3 Non -Tile Applications, Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y. -inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1 -inch diameter plastic or steel
cap nails spaced maximum 12 -inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3 -inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.12.10-1111
Certificate of Authorization #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 7 of 8
ONEMOletc.
6.7.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSea JIT or Boral MetalSeal"T over ASTM D226, Type II felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal"T
or Boral MetalSeal"T with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Brentwood, NH
QUALITY9.
UL, LLC. — QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report M35710.12.10-1111
Certificate ofAuthorizatian #32455 CH EDITION (2017) FBC NON-HVH2 EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 8 of 8
AFTER RECORDING -RETURN TO. 111111111111111111111111111111111111111111111
CFH 20200015223
Ois E:K 31154 PG 1399
RECORDED 01/13/2020 13:36:04
PERMIT NUMBER: Palm Beath C4Unt9e Florida
Sharon R. Bo°_ktC.LERK tr COMPTROLLER
NOTICE OF COMMENCEMENT F'9 1899; (1 p 9 )
The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713,
Florida Statutes, the following information is provided in this Notice of Commencement.
1. DESCRIPTION OF PROPERTY (Legal description of the property & street address, if available) TAX FOLIO NO.: 00-4042-24-00-000-6200
SUBDIVISION LOT BLDG UNIT
2. GENERAL DESCRIPTION OF IMPROVEMENT:
RESIDENTIAL REROOF
3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT:
a. Name and address: EDWARD & MARK SCHIEBER; 16409 TEMPLE BLVD LOXAHATCHEE FL 33470
b. Interest in property: OWN E R
c. Name and address offee simple titleholder (ifdifferent from Owner listed above):
4. a. CONTRACTOR'S NAME: ROOFING SYSTEMS OF FLORIDA. INC
Contractor's address: 583 105TH AVE N SUITE 9 ROYAL PALM BEACH FL 33411 b.Ph°neanmber 561-795-5566
5. SURETY (if applicable, a copy of the payment bond is attached):
a. Name and address:
b. Phone number:
6. a. LENDER'S
Lender's address:
c. Amount ofbond:
Phone
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13 (1) (a) 7., Florida Statutes:
a. Name and address:
b. Phone numbers of designated persons:
8. a. In addition to himself or herself, Owner designates of—
to
f_to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florida Statutes.
b. Phone number of person or entity designated by 0—
9. Expiration date of notice of commencement (the expiration date will be 1 year from the date of recording unless a different date is
specified): , 20_
(Signature WAAwneror Lessee, or Owner's or Lessee's
Authorized Officer/Director/Partner/Manager)
State of FLORIDA
County of PALM BEACH
(V,% to►, ►C- 5 c L%,P1, .--
(Print Name and Provide Signatory's Tide/Office)
The foregoing instrument was acknowledged before me this (a day of--Ir� 20 C.A.J
by \ as
(name of person) (type of authority,... e.g. officer, trustee, attorney in fact)
for
(name of party on behalf of whom instrument was executed)
Personally Known or Produced Identification�Type of Identifica ' It Produced 1
Felicia LdChaw
* z commissil)R41WOMU
�j�,Exon Wary 13, 2022 (Signature of tory Public)
BW(W f n AM t, Type, or Stamp Commissioned Name of Notary Public)
a� tat t
Rev. 10-15-12 �`° ,.e`+ STATE OF FLORIDA a PALM BEACH COUNTY
' 9 t hereby certify that the foregoing is a
,j true copy of the record in my office with
redo (�p�jf aequired by I
THIS'DAY OF
AM
-----'---x_.,20__
° r° r � ° �R.BOCK
ROLLER
By
CL.ERK