HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 125 Block 5 -... -"" "" """ -_- 1512 CGR
Builder Name: ADAMS HOMES
Street: 5336 San Bendeho Place
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zane 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1641.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1346.20 ft'
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c. WA
R=13.0 294.94 ft2
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1612.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1512.00 ft2
6. Conditioned Floor area above grade (112) 1512
b. N/A
R= ft2
Conditioned Floor area below grade (ft2) 0
c. A
R= ft2
11. Ducts
R ft2
7. Windows(174.2 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 302.4 "
a. U-Factor: Dbl, U=0.33 118.38 112
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 35.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 3.00 ft2
a. Electric Heat Pump
28.2 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 3.533 ft.
Area Weighted Average SHGC: 0.275
14. Hot water systems
8. Floor Types (1612.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2
b. Conservation features
EF: 0.940
b. NIA R= ft2
None
c. NIA R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.115 Total Proposed Modified Loads: 51.43
PASS
Total Baseline Loads: 53.56
I hereby certify that the plans and specifications covered by
Review of the plans and
S24l,
this calculation are in complianc ihe Florida E\
specifications covered by this
O�-THE
i'� _ �. O
Code.
calculation indicates compliance
y`� i,,b% 's `:' �:%
with the Florida Energy Code.
!ti tops, �',--Y,e`°°;'..�O
PREPARED BY:
Before construction is completed
r
DATE: 05-27-20 Winn Keomany
this building will be inspected for
compliance with Section 553.908
* °
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
�C'0
with the Flori Ener Code.
Wr,
OWNER/AG ��
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and tf6imfAt requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
JUN 15 2020
Permitting Department
St. Lucie County
5/27/2020 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) CCo1 of%0w%u py Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 125 Block 5 Hickory Ridge Bedrooms: 3
User Conditioned Area: 1512
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 125
Block/Subdivision: Waterslone
PlatBook:
Street: 5336 San Bendetto Pla
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
1/ Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1512 13608
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
1512 13608 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0
1512 ft' __-- 0.47 0 0.53
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pilch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1691 ft' 378 ft' Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1512 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Fmc Truss Type
1
Under Attic (Vented)
Main 30 Blown
1512 ft- 0.11 Wood
5/27/2020 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
i
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
_ 1
SW
Exterior
Concrete Block - Int Insul
Main
4.1 39
9
8 9
347.8 ft2
0
0 0.6
0
-2
W
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft2
0
0 0.6
0
-3
NW
Exterior
Concrete Block- Int Insul
Main
4.1 18
2
8 3
149.9 ft2
0
0 0.6
0
4
N
Exterior
Concrete Block - Int Insul
Main
4.1 2
3
8 0
18.0 ft2
0
0 0.6
0
-5
NE
Exterior
Concrete Block- Int Insul
Main
4.1 53
7
8 7
459.9 ft2
0
0 0.6
0
6
BE
Exterior
Concrete Block - Int Insul
Main
4.1 41
1
8 7
352.6 ft2
0
0 0.6
0
7
-
Garage
Frame - Wood
Main
13 35
9
8 3
294.9 ft2
0
0.23 0.01
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW
Insulated Main
None
.25
3
6 8
20 112
2
-
Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SW 1
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
13 ft 0 in
1 114 In
None
Exterior 5
2
SW 1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 It 0 in
0 It 10 in
Drapes/blinds
Exterior 5
3
W 2
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
4
NW 3
Vinyl Low-E Double
Yes
0.33 0.31
N
3.0 ft2
7 8 4 in
0 It 9 in
None
None
5
NW 3
Vinyl Low-E Double
Yes
0.33 0.21
N
15.0 ft2
1 ft 41n
1 ft 0 in
Drapestblinds
Exterior 5
6
N 4
Vinyl Low-E Double
Yes
0.33 0.21
N
10.0 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
7
NE 5
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
1 ft 0 in
Dmpes/blinds
Exterior 5
8
NE 5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
9
SE 6
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft2
6 ft 8 in
0 It 10 in
Drapes/blinds
Exterior 5
10
BE 6
Vinyl Low-E Double
Yes
0.33 0.23
N
23.2 112
1 ft 4 in
1 ft 0 In
Drapes/blinds
Exterior 5
11
SE 6
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
390 ft2 390 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004
1587.6 87.16
163.91
.1454
7
5/2712020 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
1
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 28.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15 28.4 kBtu/hr 947 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use
SelPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
DUCTS
Supply—
V # Location R-Value Area
—Return Air
Location Area Leakage Type Handler
CFM 25
TOT
CFM25
OUT
ON
RLF
HVAC#
Heat Cool
1 Attic 6 302.4 ft Main
75.6 ft' Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling[[ ]]Jan [[ ]]Feb jr Mar
Heatin[X] Jan [X] Feb [X� Mar
Venting 11 Jan r 1 Feb (X Mar
Ceiling Fans:
A r r[ Ma Jun [[X]] Jul [X] Au
Apr [ May n Jun r ) Jul r ] Aug
Jun r 1 Jul r 1 Aug
[X] Se
[ ] Sep
11 Sep
Oct
Oct
[[X]] Nov
[X] Nov
Dec
Dee
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling(WD) AM 78
PM 80
Cooling(WEH) AM 78
PM 78
Heating(WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78 78
78 78 78 78
78 78 78 78
78 78 78 78
66 66 68 68
68 68 68 68
66 66 68 68
68 68 68 68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fr ction
Space
Default 8 Ibs/s .ft.
0 ft'
0 ft 0.3
Main
5/27/2020 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
.t
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
S. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
28.4
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1512
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.352
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.275
14. Heating system: Capacity
28.2
c) Area
7c. 174.2
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
91b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
t0A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 13.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
1la. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
I) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy
Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Sign; •
--
Date:
Address of New Home: 5336 San Bendetto Place City/FL Zip: Fart Pierce, FL 34951
5/27/2020 2:25:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1