Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 125 Block 5 -... -"" "" """ -_- 1512 CGR Builder Name: ADAMS HOMES Street: 5336 San Bendeho Place Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zane 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1641.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1346.20 ft' 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. WA R=13.0 294.94 ft2 R= ft2 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1612.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned Floor area above grade (112) 1512 b. N/A R= ft2 Conditioned Floor area below grade (ft2) 0 c. A R= ft2 11. Ducts R ft2 7. Windows(174.2 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 302.4 " a. U-Factor: Dbl, U=0.33 118.38 112 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 35.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 3.00 ft2 a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 3.533 ft. Area Weighted Average SHGC: 0.275 14. Hot water systems 8. Floor Types (1612.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features EF: 0.940 b. NIA R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.115 Total Proposed Modified Loads: 51.43 PASS Total Baseline Loads: 53.56 I hereby certify that the plans and specifications covered by Review of the plans and S24l, this calculation are in complianc ihe Florida E\ specifications covered by this O�-THE i'� _ �. O Code. calculation indicates compliance y`� i,,b% 's `:' �:% with the Florida Energy Code. !ti tops, �',--Y,e`°°;'..�O PREPARED BY: Before construction is completed r DATE: 05-27-20 Winn Keomany this building will be inspected for compliance with Section 553.908 * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. �C'0 with the Flori Ener Code. Wr, OWNER/AG �� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and tf6imfAt requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). JUN 15 2020 Permitting Department St. Lucie County 5/27/2020 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) CCo1 of%0w%u py Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 125 Block 5 Hickory Ridge Bedrooms: 3 User Conditioned Area: 1512 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 125 Block/Subdivision: Waterslone PlatBook: Street: 5336 San Bendetto Pla County: St. Lucie City, State, Zip: Fort Pierce , FL , 34951 CLIMATE / 1/ Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1512 13608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1512 13608 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1512 ft' __-- 0.47 0 0.53 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pilch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1691 ft' 378 ft' Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1512 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Fmc Truss Type 1 Under Attic (Vented) Main 30 Blown 1512 ft- 0.11 Wood 5/27/2020 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 SW Exterior Concrete Block - Int Insul Main 4.1 39 9 8 9 347.8 ft2 0 0 0.6 0 -2 W Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 -3 NW Exterior Concrete Block- Int Insul Main 4.1 18 2 8 3 149.9 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 -5 NE Exterior Concrete Block- Int Insul Main 4.1 53 7 8 7 459.9 ft2 0 0 0.6 0 6 BE Exterior Concrete Block - Int Insul Main 4.1 41 1 8 7 352.6 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 13 35 9 8 3 294.9 ft2 0 0.23 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NW Insulated Main None .25 3 6 8 20 112 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 13 ft 0 in 1 114 In None Exterior 5 2 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 It 0 in 0 It 10 in Drapes/blinds Exterior 5 3 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 4 NW 3 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft2 7 8 4 in 0 It 9 in None None 5 NW 3 Vinyl Low-E Double Yes 0.33 0.21 N 15.0 ft2 1 ft 41n 1 ft 0 in Drapestblinds Exterior 5 6 N 4 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 7 NE 5 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Dmpes/blinds Exterior 5 8 NE 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 9 SE 6 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 6 ft 8 in 0 It 10 in Drapes/blinds Exterior 5 10 BE 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 112 1 ft 4 in 1 ft 0 In Drapes/blinds Exterior 5 11 SE 6 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 390 ft2 390 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1587.6 87.16 163.91 .1454 7 5/2712020 2:25 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 1 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SelPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS Supply— V # Location R-Value Area —Return Air Location Area Leakage Type Handler CFM 25 TOT CFM25 OUT ON RLF HVAC# Heat Cool 1 Attic 6 302.4 ft Main 75.6 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Cooling[[ ]]Jan [[ ]]Feb jr Mar Heatin[X] Jan [X] Feb [X� Mar Venting 11 Jan r 1 Feb (X Mar Ceiling Fans: A r r[ Ma Jun [[X]] Jul [X] Au Apr [ May n Jun r ) Jul r ] Aug Jun r 1 Jul r 1 Aug [X] Se [ ] Sep 11 Sep Oct Oct [[X]] Nov [X] Nov Dec Dee Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 PM 80 Cooling(WEH) AM 78 PM 78 Heating(WD) AM 66 PM 68 Heating (WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fr ction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 5/27/2020 2:26 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 .t 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) S. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1512 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.352 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.275 14. Heating system: Capacity 28.2 c) Area 7c. 174.2 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 91b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) t0A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit I) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Sign; • -- Date: Address of New Home: 5336 San Bendetto Place City/FL Zip: Fart Pierce, FL 34951 5/27/2020 2:25:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1