HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 25 Block 2 Walerstone 2010 CRGL Builder Name: ADAMS HOMES Street: 8200 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number. Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1472.0 sgft.) Insulation Area 2. Single famlVor multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1308.00 ft2 b. Frame - Wood, Adjacent R=13.0 164.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2010.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2010.00112 6. Conditioned floor area above grade (ft2) 2010 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(200.5 sgft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 402 a. U-Factor: Dbi, U=0.33 127.17 ft2 SHGC: SHGC=0.23 b. U-Factor: Dial, U=0.33 55.56 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEERA6.50 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Healing systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heal Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.843 ft. Area Weighted Average SHGC: 0.266 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2010.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2010.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Patel Glass/Floor Area: 0.100 Total Proposed Modified Loads: 59.41 PASS Total Baseline Loads: 59.96 1 hereby certify that the plans and specifications covered by Review of the plans and S7, this calculation are in complianc Nspecifications covered by this OFTHB , O A4% Code. calculation indicates compliance y`t .i„ `'% ` e with the Florida Energy Code.�O PREPARED BY: Before construction is completed o DATE: 2-17a021 this building will be inspected for compliance with Section 553.908 a A . n I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Codas \ Q'Ob W8'i¢� OWNER/AQ€N,. �� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). RECEIVED MAY 2 9 1010 Permitting Department St. Lucie County 2/17/2020 9:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 25 Block 2 Waterstone 20 Bedrooms: 3 User Conditioned Area: 2010 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 25 Block/Subdivision: Waterstone PlalBook: Street: 8200 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Healing Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2010 17286 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2010 17286 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Pedmeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 163.4 ft 0 2010 ft' 0.35 0 0.66 ROOF _ / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2248 ft' 504 ft' Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2010 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2010 ft2 0.11 Wood 2/17/2020 9:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space- 1 S Exterior Concrete Block - Int Insul Main 4.1 36 0 8 0 288.0 ft2 0 0 0.6 0 -2 W Exterior Concrete Block - Int Insul Main 4.1 21 6 8 0 172.0 ft2 0 0 0.6 0 -3 N Exterior Concrete Block - Int Insul Main 4.1 36 0 8 0 288.0 ft' 0 0 0.6 0 4 E Exterior Concrete Block - Int Insul Main 4.1 56 0 8 0 448.0 ft" 0 0 0.6 0 _ 5 - Garage Frame - Wood Main 13 20 6 8 0 164.0 ft' 0 0.23 0.01 0 6 W Exterior Concrete Block -Int Insul Main 4.1 14 0 8 0 112.0 ft2 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ft- 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 11 in None None 2 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 4 in 0 ft l l in None None 3 W 2 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 1 ft 4 in 0 ft 11 in None None 4 W 6 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft2 6 ft 0 in 1 It 6 in None None 5 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 4 in Oft 11 in None None 6 E 4 Metal Low-E Double Yes 0.55 0.7 N 17.8 ft2 1 ft 0 in 1 ft 0 in None None 7 E 4 Vinyl Low-E Double Yes 0.33 0.23 N 80.9 ft2 1 ft 4 in 0 ft 11 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 425 ft2 425 112 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000383 2016.7 110.71 208.21 .1364 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 2/17/2020 9:50 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATERSYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft. DUCTS Supply— --Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 402 ft2 Main 100.5 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans: Jan Feb Heating ( Jan H Feb [[ ]] H Mar (j [ ] Apr E D(� [X] ] MayMay [) Jun [ ] Jul [f ]] [x] Aug �X] ] [ ] Sep L 1 [rX,] Dec Venting (1 Jan [ I Feb IXl Mar IXl I) I 1 Jun I 1 Jul I[ 1 Aug I I Sep lxl Q Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WO) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68, 68 68 68 68 66' 66 Healing (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 2/17/2020 9:60 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2010 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.350 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.266 14. Heating system: Capacity 34.6 c) Area 7c. 200.5 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 81b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 91b. 15. Water healing system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 1 to. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Sigryatur Date: Q- Address of New Home: 8200 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951 2/17/2020 9:51:06 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1