Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 1 Block 1 Waterstone 1780 BGR Builder Name: ADAMS HOMES Street: 5456 Lugo Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1513.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1245.40 ft- b. Frame - Wood, Adjacent R=13.0 268.00 ft- 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (1900.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1780.00 ft- 6. Conditioned floor area above grade (W) 1780 b. Knee Wall (Vented) R=19.0 120.00 ft- Conditioned Floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(177.0 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 356 a. U-Factor: Dbl, U=0.33 113.31 ft- SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 45.94 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft' SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U.-Factor: N/A ft' a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.639 ft. Area Weighted Average SHGC: 0.272 14. Hot water systems a. Electric Cap: 40 gallons B. Floor Types (1780.0 sgft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation. R=0.0 1780.00 ft- b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.099 Total Proposed Modified Loads: 55.89 PASS Total Baseline Loads: 56.40 1 hereby certify that the plans and specifications covered by Review of the plans and O�TtiB STq� this calculation are in compli th the FloricIAZeerffT specifications covered by this ,y Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed u DATE: 06-09-9070 Winn Kenman� this building will be inspected for compliance with Section 553.908 0 '- I hereby certify that this building, as deal ned, is in compliance Florida Statutes. with the Florida T�2rgy-6s G'Oj11N1•y{i ` OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 on for whole house. 6/9/2020 3:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT 'rife: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 1 Block 1 Waterstone 178 Bedrooms: 3 User Conditioned Area: 1780 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 1 Block/Subdivision: Waterstone PlatBook: Street: 5456 Lugo Street County: St. Lucie City, State, Zip: Fort Pierce, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1780 15664 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1780 16664 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0 1780 ft' ---- 0.38 0 0.62 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1991 W 446 ft' Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Knee Wall (Vented) Under Attic (Vented) Main 19 Batt Main 30 Blown 120 ft' 0.11 Wood 1780 ft' 0.11 Wood 6/9/2020 3:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 SE Exterior Concrete Block - Int Insul Main 4.1 40 0 8 0 320.0 ft- 0 0 0.6 0 -2 SW Exterior Concrete Block - Int Insul Main 4.1 40 6 8 0 324.0 ft- 0 0 0.6 0 -3 W Exterior Concrete Block- Int Insul Main 4A 3 0 9 6 28.5 ft' 0 0 0.6 0 -4 NW Exterior Concrete Block - Int Insul Main 4.1 11 10 9 6 112.4 ft' 0 0 0.6 0 _ 5 N Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft- 0 0 0.6 0 _ 6 NE Exterior Concrete Block - Int Insul Main 4.1 54 0 8 0 432.0 ft' 0 0 0.6 0 7 - Garage Frame - Wood Main 13 33 6 8 0 268.0 W 0 0.23 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In _ 1 NW Insulated Main None .25 3 6 8 20 ft' 2 - Woad Main None A6 2 8 6 8 17.8 ft- WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Metal Low-E Double Yes 0.65 0.7 N 17.8 ft' 14 ft 4 in 0 ft 10 in None None 2 SE 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft- 1 ft 4 in 0 It 10 in Drapes/blinds None 3 SW 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 1 ft 4 in 0 ft10 in Drapes/blinds None 4 W 3 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds None 5 NW 4 Vinyl Low-E Double Yes 0.33 0.21 N 23.2 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds None 6 N 5 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds None 7 NE 6 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 W 1 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 591 ft' 591 ft' 64 It 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehcuse Proposed ACH(50) .000391 1827.5 100.33 188.68 .1409 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 28.2 kBtu/hr 1 sys#1 6/9/2020 3:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtuRv 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 356 ft= Main 89 ft' Proposed On Main --- cfm 106.8 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinJan Feb Mar Mar Apr Apr Ma Jun Jul May Jun Jul Au Aug Se Sep Oct Oct r' Nov ( Nov ec Dec HD Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default Ibs/s .ft. 0 ft- Oft 0.3 Main 6/9/2020 3:49 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No, of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1780 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.352 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.272 14. Heating system: Capacity 28.2 c) Area 7c. 177.0 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 90. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signa ` Date: Address of New Home: 5456 Lugo Street City/FL Zip: Fort Pierce, FL 34951 6/9/2020 3:50:02 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1