HomeMy WebLinkAboutEnergy CodeFO ae
FORM R405-2017 ps/ty�' Bj2?DIO �FO
tk FLORIDA ENERGY'Fj ` IENCY CODE FOR BUILDINQj6C%%%RUCTION
Florida Department of Busin s sand Professional Regulation - Residenti& nce Method
NHtu enr
Project Name: Lot20 Block 68-8 Indian River Estates 2320BGR
Builder Name: ADAMS HOMES
Street: 5907 Birch Drive
Permit Office:
City, State, Zip: Fort Pierce , FL , 34982
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1874.5 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1530.00 W
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 215.33 ft-
c. Frame -Wood, Exterior
R=13.0 129.19 @'
4. Number of Bedrooms 4
d. N/A
R= ft-
5. Is this a worst case? No
10. Ceiling Types (2382.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2332.00 ft-
6. Conditioned Floor area above grade (ft-) 2332
b. Knee Wall (Vented)
R=19.0 50.00 ft'
Conditioned Floor area below grade (ft) 0
c. N/A
R= fta
7. Windows(263.2 sgft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft'
6 466.4
a. U-Factor: Dbl, U=0.33 151.15 ft'
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft-
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.33 23.33 ft'
SHGC: SHGC=0.31
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 17.78 ft'
a. Electric Heat Pump
42.0 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 3.343 ft.
Area Weighted Average SHGC: 0.263
14. Hot water systems
8. Floor Types (2332.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2332.00 ft-
b. Conservation features
EF: 0.940
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.113 I Total Proposed Modified Loads: 70.86 I
PASS
Total Baseline
Loads: 71.43
I hereby certify that the plans and specifications covered by
Review
I ST
this 't
of the plans and
04T1is
calculation are in compliance a Florida Enelgyr-1�
specifications covered by this
= O
Code.
calculation indicates compliance
y`t�' i�;�6j' =9's A
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 1-3n_
this building will be inspected for
A
compliance with Section 553.908*
a
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
,
with the Florida E ode.
, COD WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
9 envelope leakage test report with envelope leakage no greater thrg�Op,�6jj,5,p,{ff4,0
I 'Q��99 44f1l1�lI1>�:66,,dd''2#.0R
CODE COMPLIANCE
ST, LIUCIEppvvC��yOfl. NTY FILE dopy
1/30/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6t929, 2017) Compliant Software Page 1 of 5
00
is
FORM R405-2017 INPUT RI IMMARV (tl4FR1l1 1_CT RFPnPT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
. Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot20 Block 68-8 Indian River Bedrooms: 4
User Conditioned Area: 2332
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
20
IndianRiverEst.
5907 Birch Drive
St. Lucie
Fort Pierce ,
FL, 34982
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Healing Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2332 20754.8
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
2332 20754.8 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 201.6 ft 0
2332 ft- ___
0.36 0 0.64
ROOF
#
Typel
Roof Gable Roof
Materials Area Area Color
Re Solar SA Emitt
Bar Afbsor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Sh�d Composition shingles 2608 ft' 584 ft' Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2332 ft- N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
*.— 3
Knee Wall (Vented)
Knee Wall (Vented)
Under Attic (Vented)
Main 19 Batt
Main 19 Batt
Main 30 Blown
30 ft- 0.11
20 ft' 0.11
2332 ft' 0.11
Wood
Wood
Wood
1/30/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPI IT SI IMMAPV r=rut 14ZT DCDnOT
WALLS
Adjacent
Spam
Cavity Width
Height
Sheathing Framing
Solar Below
IL7ypa
P
a_V Ft
IR
FtJ
/+
c \/ Iue-FiaCtinriAh
1
N
Exterior
Frame - Wood
Main
13 1
3
9 9
12.2 ft2
0
0.23
0.6
0
2
N
Exterior
Concrete Block - Int Insul Main
4.1 51
0
8 0
408.0 ft2
0
0
0.6
0
3
E
Exterior
Concrete Block - Int Insul
Main
4.1 39
6
8 0
316.0 ft2
0
0
0.6
0
4
S
Exterior
Frame - Wood
Main
13 1
3
9 9
12.2 ft2
0
0.23
0.6
0
5
S
Exterior
Concrete Block - Int Insul
Main
4.1 57
3
8 0
458.0 ft2
0
0
0.6
0
-6
SW
Exterior
Frame - Wood
Main
13 2
11
9 9
28.4 ft2
0
0.23
0.6
0
7
W
Exterior
Frame - Wood
Main
13 4
11
9 9
47.9 ft2
0
0.23
0.6
0
8
W
Exterior
Concrete Block - Int Insul Main
4.1 43
6
8 0
348.0 ft2
0
0
0.6
0
9
NW
Exterior
Frame - Wood
Main
13 2
11
9 9
28.4 112
0
0.23
0.6
0
10
-
Garage
Frame - Wood
Main
13 26
11
8 0
215.3 ft2
0
0.23
0.6
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated
Main
None
.25
3
6 8
20 it-
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V
Wall
Overhang
#
Ornt
ID
Frame Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Sepamflon
Int Shade
Screening
1
N
2
Vinyl Low-E Double
Yes
0.33 0.23
N
9.0 ft2
1 ft 4 in
0 it 10 in
None
None
2
N
2
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
None
None
3
E
3
Vinyl Low-E Double
Yes
0.33 0.31
N
10.0 ft2
9 It 4 in
0 ft 4 in
None
None
4
E
3
Vinyl Low-E Double
Yes
0.33 0.21
N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
None
5
E
3
Vinyl Low-E Double
Yes
0.33 0.21
N
38.5 ft2
1 ft4 in
2 ft 6 in
None
None
6
E
3
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
9 it 4 in
2 ft 4 in
None
None
7
S
5
Vinyl Low-E Double
Yes
0.33 0.23
1 N
16.2 ft2
1 it 4 in
0 ft 10 in
None
None
8
SW
6
Vinyl Low-E Double
Yes
0.33 0.23
N
12.5 ft2
1 ft 4 in
0 ft 10 in
None
None
9
W
7
Vinyl Low-E Double
Yes
0.33 0.23
N
20.0 ft2
1 it 41n
0 It 10 in
None
None
10
I W
8
Vinyl Low-E Double
Yes
0.55 0.7
N
1 17.8 112
11 it 4 in
1 it 0 in
None
None
11
I W
8
Vinyl Low-E Double
Yes
0.33 0.23
N
1 48.6 ft2
1 ft4 in
0 ft 10 In
None
None
12
NW
9
Vinyl Low-E Double
Yes
0.33 0.23
N
12.6 ft2
1 ft4 in
0 ft 10 in
None
None
13
W
8
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
11 ft 6 in
0 ft 10 in
Drapesiblinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
437 ft2 437 ft2
64 ft
8 It
1
1/30/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
.i
FORM R405-2017 INPUT SUMMARY CHFCKI.IST RFPnRT
INFILTRATION
1 # Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000396
2421.4 132.93 250 .1432 7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15 42 kBtu/hr 1400 cm 0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SeWnt Conservation
1 Electric None
Garage
0.94 40 gal 70 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
fN
DUCTS
/ — Supply —
V # Location R-Value Area
— Return— Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON
RLF
HVAC #
Heat Cool
1 Attic 6 466.4 ft
Main
116.6 ft Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programabl[e ]Thermosta[[t:��Y
Heal ng [X] Jan [X] Feb H Mar
Venting [) Jan [) Feb X Mar
Ceiling Fa s: rr[[ ]] rr[[ ]] �rX (` ]]
Apr [ May lXl Jun lXl JJulul [ Aug lXl Sep Oct
[]
lxl Nov
Nov
I ec
I
1
i
1/30/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT Si IMMARV m4p:rvf ICT D=DnOT
Thermostat Schedule:
HERS 2006 Reference
- --------
--
Hours
Schedule Type
1
2
3
4
5
6
7
8
g
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Healing (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 W
0 ft
0.3
Maln
1/30/2020 4:37 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
s�
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
3. No. of units (if multiple -family) 3. 1 c) AHU location Main
4. Number of bedrooms
4.
4
5. Is this a worst case? (yes/no)
5.
No
6. Conditioned floor area (sq. ft.)
6.
2332
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.345
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.263
c) Area
7c.
263.2
8. Skylights
a) U-factor:(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
9c.
10. Wall type and insulation:
A. Exterior:
1. Wood frame (insulationlR-value)
10A1.
13.0
2. Masonry (Insulation R-value)
10A2.
4.1
B. Adjacent:
1. Wood frame (Insulation R-value)
10137.
13.0
2. Masonry (Insulation R-value) i,
10132.
I
11. Ceiling type and insulation level
a) Under attic
11 a.
30.0
b) Single assembly
11 b.
c) Knee walls/skylight walls
11c.
19.0
d) Radiant barrier installed
11 d.
No
13. Cooling system:
Capacity 42.0
a) Split system
SEER 15.0
b) Single package
SEER
c) Ground/water source SEER/COP
d) Room unit/PTAC
EER
e) Other
14. Heating system: Capacity 42.0
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
I) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature c
Address of New Home: 5907 Birch Drive City/FL Zip: Fort Pierce, FL 34982
1/30/2020 4:37:46 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1