HomeMy WebLinkAboutKHOV-WS-L5-BLOWERDOOREnvelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit #: (Cl d--------------- job,lnformation _ Builder: community: 6v-- Lot: JtCvl, Address A-M"(Y, Unit: '" State: Zip: S city: for - A -erc R- ,A1rLeakageT@SC Re's�11ts , Possingresults mustmeet either the Performonce, Prescrtptive, or ERI Method PRESGRIPTIIr'�METHOD The building or dwelling unit"shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hourat a pressure of 0.2 inch rvg. (50 pascals) In Climate Zones 1 and 2. PERFORMANCE fir ERI METHOD- The -building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding i "a he selected ACH(59) value, as shown on �FORM,R405-2017 (Performance) or R406-2017 (ERIJ,:section labeled as Infiltration, sub -section AC,H l ACH{5gspeclfled on Porm. R40S-2017-Energy cafe (Performance) or R406 2017 00.' C� I.Sol- x 60 CFM(50) PASS 91019 0)- Building Volume ❑FAIL ACH(50) F-jWhen ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating buildingyolume: 0 Retrieved from architectural plans Code software calculated 0 Field measured and calculated Testing. Testing shall be conducted in accordance with ANSIIRESNEPICC 380 and reported at a pressure or 0.2 inche w.g. (50 Pascals); Testong 6 shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statues, or Individuals licensed as set forth in Section 489. I (�5(3)(f). (8}, or (i) pr an approved thied party: A written report of the results of the test shall be signed by the party eon ductfngthe test and proided to the.code official. Testing shah bepe'rformed at any time after creation, of all penetrations of the building thermal enveloped +r During testing:' 1,Exterlorwindows and doorsAreplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other Infiltratlor control Measures 2,0a wipers inchl' ing exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond Intended I'filtepdon t Fttl o t1teaSUreS 1r t wA� 3.1nerior doors; If Ins talledat tfie time of the test, shall be open: 4,xterior doors for contlnuousventilation systems and heat recovery ventiiators_shall be closed and sealed. M� 5 Heating and cooling systems, if Installed at the time of the test; shall be turned off. M- M l 6.SPpOly and return registers, If. installed at the time of the test; shall be fully"open, a .,A.Y T�sttng Company' <a ` rl ompany Name: SQSAr 1l�G.UC� Phone: &6"� 1� ereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy nservation requirements according 0 the cAmpliance method selected above. Signature of Tester: Printed Name of Tester: 1, Date of Test:7/ado �ss, t) t-:� -F License/Certification #:�iCj= Issuing Authority: