HomeMy WebLinkAboutDesign Pressure ReportProperty Information
Owner:Susan Zimmer or Lynda Gibbons
Address:4804 Silver Oak Dr
Fort Pierce, FL 34982
Building Information
Wind Zone:170 MPH.
Exposure Category:C
Minimum Building Dimension:35 ft.
Mean Roof Height:12 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 Int 73 49 7 35.6 -38.8
2 Int 34 37 7 37.8 -41.0
3 Int 52 37 7 37.1 -40.3
4 Int 36 49 7 37.3 -40.5
5 Int 36 49 7 37.3 -40.5
6 Int 36 37 7 37.8 -41.0
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code.