Loading...
HomeMy WebLinkAboutDesign Pressure ReportProperty Information Owner:Susan Zimmer or Lynda Gibbons Address:4804 Silver Oak Dr Fort Pierce, FL 34982 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:35 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 73 49 7 35.6 -38.8 2 Int 34 37 7 37.8 -41.0 3 Int 52 37 7 37.1 -40.3 4 Int 36 49 7 37.3 -40.5 5 Int 36 49 7 37.3 -40.5 6 Int 36 37 7 37.8 -41.0 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1