HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: ADAMS HOMES- 2265 MODEL A
Builder Name: ADAMS HOMES
Street: 8108 AMALFI. CIRCLE
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE, FL, 34951
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2016.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul,Exterior
R=4.1 1402.00 ft2
b. Frame - Wood, Exterior
R=19.0 372.50 ft2
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=11.0 242.00 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2277.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2277.00 ft2
6. Conditioned Floor area above grade (W) 2277
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. NIAucts
R ft,
11
R
7. Windows(289.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU CLST
6 175
a. U-Factor: Sgl, U=0.65 289.03 fF
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
41.5 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
27.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.121 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (2276.5 soft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2276.50 ft2
b. Conservation features
EF: 0.980
b. N/A R= W
None
c. N/A R= if
15. Credits
None
Glass/Floor Area: 0.127 Total Proposed Modified Loads: 66.84
PASS
Total Baseline
Loads: 71.87
I hereby certify that the plans and specifications covered by
Review of the plans and
;oeTas-srgr�. ,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
the Florida Energy Code.
�p
with
PREPARED gy t w
Before construction is completed
v -
DATE: 5-25-ZUZU
this building will be inspected for
compliance with Section 553.908
:�_ - ? yti
I hereby certify that this building, as designed, is in compliance
with the Florida Code.
Florida Statutes.
C0
_
OWNER/AGENT `_�
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -seated in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY
5/22/20202:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
ADAMS HOMES- 2265 MOD
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2277
Lot #
Owner Name:
Total Stories:
1
Block/Subd!Asion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle:
0
Street:
8108 AMALFI CIRCLE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Single-family
FL, 34951
New/Epsting:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_ VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2277
20352
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
O WIC i
35
280 No
0
1
Yes
Yes
Yes
2
O WIC 2
35
280 No
0
1
No
Yes
Yes
3
0 BATH
124
992 No
0
1
Yes
Yes
Yes
4
O TOILET
24
192 No
0
1
No
Yes
Yes
5
O LINEN
20
160 No
0
1
Yes
Yes
Yes
6
LIVING ROOM
185
1850 No
0
1
Yes
Yes
Yes
7
FOYER
70
700 No
0
1
Yes
Yes
Yes
8
DINING ROOM
132
1320 No
0
1
Yes
Yes
Yes
9
FAMILY ROOM
410
4100 No
0
1
Yes
Yes
Yes
10
BREAKFAST
61
610 No
0
1
Yes
Yes
Yes
11
KITCHEN
210
2100 Yes
0
1
No
Yes
Yes
12
BATH 3
101
808 No
0
1
Yes
Yes
Yes
13
HALLWAY
42
336 No
0
1
No
Yes
Yes
14
AHU CLST
20
160 No
0
1
No
Yes
Yes
15
UTILITY
68
544 No
0
1
No
Yes
Yes
16
BATH 2
54
432 No
0
1
No
Yes
Yes
17
CLST 2
22
176 No
0
1
Yes
Yes
Yes
18
BEDROOM 2
132
1056 No
0
1
1
Yes
Yes
Yes
19
BEDROOM 3
121
968 No
0
1
1
Yes
Yes
Yes
20
CLST 3
12
96 No
0
1
Yes
Yes
Yes
21
LINEN
4
32 No
0
1
No
Yes
Yes
22
CLST 4
12
96 No
0
1
Yes
Yes
Yes
5/22/2020 2:41 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
Infil ID Finished
Cooled
Heated
23 HALL 16
128
No 0
1 No
Yes
Yes
24 BEDROOM 4 143
1144
No 0
1
1 Yes
Yes
Yes
25 OWNERS BEDRO 224 1792
No 0
1
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
O W IC 1
7 ft
0
35 ft2
_
1
0
0
2 Slab -On -Grade Edge Insulalio
O W IC 2
1 It
0
35 ft'
_
1
0
0
3 Slab -On -Grade Edge Insulatio
O BATH
6 ft
0
124 ft'
—
1
0
0
4SIab-On-Grade Edge Insulatio
O TOILET
1 ft
0
24 ft2
—
1
0
0
5SIab-On-Grade Edge Insulatio
O LINEN.
4 it
0
20 ft2
—
1
0
0
6 Slab -On -Grade Edge Insulatio
LIVING ROOM
34 ft
0
185 ft2
—
1
0
0
7 Slab -On -Grade Edge Insulatio
FOYER
7 it
0
70 ft2
__
1
0
0
8SIab-On-Grade Edge Insulatio
DINING ROOM
12 ft
0
132 ft'
1
0
0
9 Slab -On -Grade Edge Insulatio
FAMILY ROOM
17 it
0
410 ft2
__
1
0
0
10SIab-On-Grade Edge Insulatio
BREAKFAST
8.2 ft
0
61 W
__
1
0
0
11Slab-On-Grade Edge Insulatio
KITCHEN
1 ft
0
210 ft2
1
0
0
12SIab-On-Grade Edge Insulatio
BATH 3
15 it
0
100.5 ft2
__
1
0
0
13SIab-On-Grade Edge Insulatio
HALLWAY
1 it
0
42 ft'
__
1
0
0
14SIab-On-Grade Edge Insulatio
AHU CLST
1 it
0
20 ft'
1
0
0
15SIab-On-Grade Edge Insulatio
UTILITY
1 ft
0
68 f12
1
0
0
16SIab-On-Grade Edge Insulatio
BATH 2
1 ft
0
54 ft2
1
0
0
17SIab-On-Grade Edge Insulatio
CLST 2
2 ft
0
22 W
__
1
0
0
18Slab-On-Grade Edge Insulatio
BEDROOM 2
12 ft
0
132 ft2
_
1
0
0
19SIab-On-Grade Edge Insulatio
BEDROOM 3
11 it
0
121 ft2
_
1
0
0
20SIab-On-Grade Edge Insulatio
CLST 3
2 fl
0
12 ftt2
—
1
0
0
21SIab-On-Grade Edge Insulatio
LINEN
1 ft
0
4 ft'
—
1
0
0
22SIab-On-Grade Edge Insulatio
CLST 4
2 fl
0
12 ft'
_
1
0
0
23SIab-On-Grade Edge Insulatio
HALL
1 ft
0
16 ft2
1
0
0
24SIab-On-Grade Edge Insulatio
BEDROOM 4
24 It
0
143 W
—
1
0
0
25SIab-On-Grade Edge Insulatio
OWNERS BEDR
39 It
0
224 ft2
1
0
0
5/22120202:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof
Gable
Roof Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type
Materials Area
Area
Color Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 2547 ft2
0 f12 Medium N
0.4
No 0.9
No 0
26.6
ATTIC
/
`�
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented
300
2277 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
0 W IC 1
30
Blown
35 ft-
0.1
Wood
2
Under Attic (Vented)
O WIC2
30
Blown
35 ft-
0.1
Wood
3
Under Attic (Vented)
O BATH
30
Blown
124 ft2
0.1
Wood
4
Under Attic (Vented)
0 TOILET
30
Blown
24 ft2
0.1
Wood
_
5
Under Attic (Vented)
O LINEN
30
Blown
20 W
0.1
Wood
_
6
Under Attic (Vented)
LIVING ROOM
30
Blown
185 W
0.1
Wood
7
Under Attic (Vented)
FOYER
30
Blown
70 ft2
0.1
Wood
8
Under Attic (Vented)
DINING ROOM
30
Blown
132 ft2
0.1
Wood
9
Under Attic (Vented)
FAMILY ROOM
30
Blown
410 ft2
0.1
Wood
_
10
Under Attic (Vented)
BREAKFAST
30
Blown
61 ft2
0.1
Wood
11
Under Attic (Vented)
KITCHEN
30
Blown
210 W
0.1
Wood
12
Under Attic (Vented)
BATH 3
30
Blown
101 f12
0.1
Wood
_
13
Under Attic (Vented)
HALLWAY
30
Blown
42 ft2
0.1
Wood
14
Under Attic (Vented)
AHU CLST
30
Blown
20 ft2
0.1
Wood
15
Under Attic (Vented)
UTILITY
30
Blown
68 ft2
0.1
Wood
_
16
Under Attic (Vented)
BATH 2
30
Blown
54 ft2
0.1
Wood
17
Under Attic (Vented)
CLST 2
30
Blown
22 W
0.1
Wood
18
Under Attic (Vented)
BEDROOM 2
30
Blown
132 ft2
0.1
Wood
19
Under Attic (Vented)
BEDROOM 3
30
Blown
121 W
0.1
Wood
20
Under Attic (Vented)
CLST 3
30
Blown
12 ft2
0.1
Wood
21
Under Attic (Vented)
LINEN
30
Blown
4 ft2
0.1
Wood
22
Under Attic (Vented)
CLST 4
30
Blown
12 ft2
0.1
Wood
_
23
Under Attic (Vented)
HALL
30
Blown
16 ft2
0.1
Wood
24
Under Attic (Vented)
BEDROOM 4
30
Blown
143 ft2
0.1
Wood
25
Under Attic (Vented)
OWNERS BEDR
30
Blown
224 ft2
0.1
Wood
WALLS
()�f
Adjacent
To 1AIP11 Type
Cavity Width
SpaceFt
Height
In
Ar,,
Sheathing Framing Solar Below
Crnd,o
1
E
Exterior Concrete Block - Int Insul 0 WIC 1
4.1 7
0 8 0
56.0 ft2
0 0
0.4
0
2
E
Exterior Concrete Block - Int Insul O BATH
4.1 6
0 8 0
48.0 fl2
0 0
0.4
0
_ 3
E
Exterior Concrete Block - Int Insul0 LINEN
4.1 4
0 8 0
32.0 ft2
0 0
0.4
0
4
N
Exterior Concrete Block - Int InsWVING ROO
4.1 14
0 10 0
140.0 ft2
0 0
0.4
0
5/2212020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
5
E
Exterior
Concrete Block - Int InsLIVING ROO
4.1
14
0
10 0
140.0 ft'
0
0
0.4
0
_ 6
W
Exterior
Concrete Block - Int Ins41VING ROO
4.1
6
0
10 0
60.0 ft'
0
0
0.4
0
_ 7
N
Exterior
Concrete Block - Int Insul FOYER
4.1
7
0
10 0
70.0 fV
0
0
0.4
0
8
N
Exterior
Concrete Block - Int InsDINING ROO
4.1
11
0
10 0
110.0 ft2
0
0
0.4
0
9
E
Exterior
Concrete Block - Int InsDINING ROO
4.1
1
0
10 0
10.0 ft'
0
0
0.4
0
_ 10
N
Garage
Frame - Wood DINING ROO
11
1
0
10 0
10.0 it-
0
0.1
0.4
0
_ 11
S
Exterior
Frame - Wood FAMILY ROO
19
17
0
10 0
170.0 ft'
0
0.1
0.4
0
12
BE
Exterior
Frame - Wood BREAKFAST
19
4
3
10 0
42.5 ft2
0
0.1
0.4
0
13
S
Exterior
Frame - Wood BREAKFAST
19
4
0
10 0
40.0 ft'
0
0.1
0.4
0
_ 14
E
Exterior
Frame - Wood BATH 3
19
6
0
8 0
48.0 ft'
0
0.1
0.4
0
15
S
Exterior
Concrete Block - Int Insul BATH 3
4.1
9
0
8 0
72.0 ft2
0
0
0.4
0
16
N
Garage
Frame - Wood UTILITY
11
8
0
8 0
64.0 f12
0
0.1
0.4
0
_ 17
W
Garage
Frame - Wood UTILITY
11
2
0
8 0
16.0 ft2
0
0.1
0.4
0
18
N
Garage
Frame - Wood BATH 2
11
6
0
8 0
48.0 it-
0
0.1
0.4
0
_ 19
W
Exterior
Concrete Black - Int Insul CLST 2
4.1
2
0
8 0
16.0 ft2
0
0
0.4
0
20
N
Garage
Frame - Wood CLST 2
11
11
0
8 0
88.0 ft2
0
0.1
0.4
0
21
E
Garage
Frame - Wood CLST 2
11
2
0
8 0
16.0 ft2
0
0.1
0.4
0
_ 22
W
Exterior
Concrete Block - Int InsBEDROOM 2
4.1
12
0
8 0
96.0 ft2
0
0
0.4
0
_ 23
W
Exterior
Concrete Block - Int InsBEDROOM 3
4.1
11
0
8 0
88.0 ft2
0
0
0.4
0
24
W
Exterior
Concrete Block - Int Insul CLST 3
4.1
2
0
a 0
16.0 ft2
0
0
0.4
0
_ 25
W
Exterior
Concrete Block - Int Insul CLST 4
4.1
2
0
8 0
16.0 ft2
0
0
0.4
0
_ 26
S
Exterior
Concrete Block - Int InsBEDROOM 4
4.1
11
0
8 0
88.0 ft2
0
0
0.4
0
27
W
Exterior
Concrete Block - Int InsBEDROOM 4
4.1
13
0
8 0
104.0 IF
0
0
0.4
0
_ 28
E
Exterior
Concrete Block - Int InsOWNERS BE
4.1
16
0
8 0
128.0 ft2
0
0
0.4
0
29
S
Exterior
Concrete Block - Int InsOW NERS BE
4.1
14
0
8 0
112.0 ft2
0
0
0.4
0
30
W
Exterior
Frame - Wood OWNERS BE
19
9
0
8 0
72.0 ft2
0
0.1
0.4
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NE
Insulated FOYER
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown
is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E 2
Metal Low-E Single Yes
0.65
0.25
N
9.0 ft2
2 it 0 in
1 it 4 in
None
None
2
N 4
Metal Low-E Single Yes
0.65
0.25
N
14.6 ft2
2 ft 0 in
1 it 4 in
None
None
3
N 4
Metal Low-E Single Yes
0.65
0.25
N
15.0 f12
2 It 0 in
1 ft 4 in
None
None
4
E 5
Metal Low-E Single Yes
0.65
0.25
N
15.0 ft2
2 ft 0 In
1 it 4 in
None
None
5
N 7
Metal Low-E Single Yes
0.65
0.25
N
10.0 W
7 ft 0 in
1 ft 4 in
None
None
6
N 7
Metal Low-E Single Yes
0.65
0.25
N
13.3 IF
7 it 0 in
1 it 4 in
None
None
_
7
N 8
Metal Low-E Single Yes
0.65
0.25
N
36.0 1?
2 ft 0 in
1 ft 4 in
None
None
8
S 11
Metal Low-E Single Yes
0.65
0.25
N
30.0 ft2
8 ft 8 in
1 fl4 in
None
None
5/22/2020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Omt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
9
10
11
_ 12
13
14
15
16
17
S 11 Metal
SE 12 Metal
S 13 Metal
E 14 Metal
W 22 Metal
W 23 Metal
S 26 Metal
S 29 Metal
W 30 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Law-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.65 0.25 N 17.8 ft2 8 ft 8 in
0.65 0.25 N 8.0 ft' 6 ft 0 in
0.65 0.25 N 12.0 ft2 6 It 0 In
0.65 0.25 N 15.6 ft' 6 It 0 in
0.65 0.25 N 15.0 ft2 2 ft 0 in
0.65 0.25 N 15.0 ft' 2 ft 0 in
0.65 0.25 N 15.0 ft' 2 It 0 in
0.65 0.25 N 30.0 ft2 2 It 0 in
0.65 0.25 N 17.8 ft' 4 ft 0 in
1 ft 4 in
1 ft 4 in
1 It 4 in
1 It 4 in
1 ft 4 in
1 It 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
696 ft2
696 ft2
30 ft 8 It
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000398
2374.4 130.35 245.14 .144
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 15 41.5 kBtu/hr 1245 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric
None
Garage
0.98 50 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cerl # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
fl2
5/22/2020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CMECKI IRT RFPnRT
DUCTS
/ ---- Supply --
---- Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6
175 ft' Attic
17 ft2
Default Leakage
AHU CLST
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan Feb
Venting Jan Feb
Mar r
Ma
MayrX�
Jun
[ j Jul
r
[ Aug
fX�
[ ] Sep
jr)C,)
Nov
Dec
[ JX
Apr
May
lXJ Jun
11 Jul
I Aug
11 Sep
Oct X[ ]
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
80
80
78
78
78
78
78 78
78
78
Heating (WD) AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
Heating (WEH) AM
65
65
65
65
65
65
65
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 W
0 ft
0.3
O W IC 1
Default(8 lbs/sq.ft.
ft2
ft
0.3
OWIC2
Default(B Ibs/sq.ft.
ft'
ft
0.3
O BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
O TOILET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
O LINEN
Default(8 Ibs/sq.ft.
ft'
ft
0.3
LIVING ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
FOYER
Default(8 Ibslsq.ft.
ft2
ft
0.3
DINING ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY ROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
BREAKFAST
Default(B Ibslsq.ft.
ft'
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(81bs/sq.ft.
fl2
ft
0.3
HALLWAY
Default(B Ibslsq.ft.
k2
ft
0.3
AHU CLST
Default(B lbs/sq.ft.
ft'
ft
0.3
UTILITY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 3
Default(B Ibs/sq.ft.
f12
ft
0.3
CLST 3
Default(81bs/sq.ft.
ft.
ft
0.3
LINEN
Default(8 Ibs/sq.ft.
fR
ft
0.3
CLST 4
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/s .ft.
f12
ft
0.3
OWNERS BEDRO
5/2212020 2:41 PM EnergyGaugerst USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: ST LUCIE COUNTY
Permit #:
Job Information '
Builder: ADAMS HOMES Community: Lot: NA
Address: 8108 AMALFI CIRCLE
City: PORT ST LUCIE State: FL Zip: 34951
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
O PRESCRIPTIVE METHOD -The huilaing:ordwelling unit shall be1ested and verified as having an air leakage rate of not exceeding pair
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and'2:'
0 PERFORMANCE or ERI METHOD -The building or dwelling unit shall'be tested and verified ashaving an air leakage rate of not exceeding
the selected ACH(50)value, as shown c Form R405-2017 (Performance) a R406-2017 (ERI), section labeled as infiltration, sub -section ACH50.
ACH(50) specked on Form R405-2017-Energy Calc (Performance). or R406-2017.(ERIf:
x 60 - 20352 — Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
❑ PASS 0 Code software calculated
❑ When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (1) or an approved third party. A written reportof the results of the test shall be signed by the party conducting the test and
provided to thecode official . Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, Intake, makeup air, back draft and Flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company ;
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
5/22/2020 2:42:10 PM EnergyGaugeS USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: ADAMS HOMES- 2265 MODEL A Builder Name: ADAMS HOMES
Street: 8108 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT ST LUCIE , FL, 34951 Permit Number:
U
Owner: Jurisdiction: ST LUCIE COUNTY
i
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier,
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The Insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per Inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
I
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the botto
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electricallphone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -Floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
5/22/2020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location AHU
CLST
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
41.5
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2277
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.650
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.250
14. Heating system: Capacity
27.0
c) Area
7c. 289.0
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat. Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wpod, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1. 19.0
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec0/o
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Date: '
Address of New Home: 8108 AMALFI CIRCLE
City/FL Zip: PORT ST LUCIE, FL 34951
5/22/2020 2:41:32 PM EnergyGaugeg) USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software