Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADAMS HOMES- 2265 MODEL A Builder Name: ADAMS HOMES Street: 8108 AMALFI. CIRCLE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, 34951 Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(2016.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul,Exterior R=4.1 1402.00 ft2 b. Frame - Wood, Exterior R=19.0 372.50 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 242.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2277.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2277.00 ft2 6. Conditioned Floor area above grade (W) 2277 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. NIAucts R ft, 11 R 7. Windows(289.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 175 a. U-Factor: Sgl, U=0.65 289.03 fF SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 41.5 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 27.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.121 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (2276.5 soft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2276.50 ft2 b. Conservation features EF: 0.980 b. N/A R= W None c. N/A R= if 15. Credits None Glass/Floor Area: 0.127 Total Proposed Modified Loads: 66.84 PASS Total Baseline Loads: 71.87 I hereby certify that the plans and specifications covered by Review of the plans and ;oeTas-srgr�. , this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance the Florida Energy Code. �p with PREPARED gy t w Before construction is completed v - DATE: 5-25-ZUZU this building will be inspected for compliance with Section 553.908 :�_ - ? yti I hereby certify that this building, as designed, is in compliance with the Florida Code. Florida Statutes. C0 _ OWNER/AGENT `_� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -seated in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 5/22/20202:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ADAMS HOMES- 2265 MOD Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2277 Lot # Owner Name: Total Stories: 1 Block/Subd!Asion: # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8108 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, 34951 New/Epsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2277 20352 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 O WIC i 35 280 No 0 1 Yes Yes Yes 2 O WIC 2 35 280 No 0 1 No Yes Yes 3 0 BATH 124 992 No 0 1 Yes Yes Yes 4 O TOILET 24 192 No 0 1 No Yes Yes 5 O LINEN 20 160 No 0 1 Yes Yes Yes 6 LIVING ROOM 185 1850 No 0 1 Yes Yes Yes 7 FOYER 70 700 No 0 1 Yes Yes Yes 8 DINING ROOM 132 1320 No 0 1 Yes Yes Yes 9 FAMILY ROOM 410 4100 No 0 1 Yes Yes Yes 10 BREAKFAST 61 610 No 0 1 Yes Yes Yes 11 KITCHEN 210 2100 Yes 0 1 No Yes Yes 12 BATH 3 101 808 No 0 1 Yes Yes Yes 13 HALLWAY 42 336 No 0 1 No Yes Yes 14 AHU CLST 20 160 No 0 1 No Yes Yes 15 UTILITY 68 544 No 0 1 No Yes Yes 16 BATH 2 54 432 No 0 1 No Yes Yes 17 CLST 2 22 176 No 0 1 Yes Yes Yes 18 BEDROOM 2 132 1056 No 0 1 1 Yes Yes Yes 19 BEDROOM 3 121 968 No 0 1 1 Yes Yes Yes 20 CLST 3 12 96 No 0 1 Yes Yes Yes 21 LINEN 4 32 No 0 1 No Yes Yes 22 CLST 4 12 96 No 0 1 Yes Yes Yes 5/22/2020 2:41 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 23 HALL 16 128 No 0 1 No Yes Yes 24 BEDROOM 4 143 1144 No 0 1 1 Yes Yes Yes 25 OWNERS BEDRO 224 1792 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio O W IC 1 7 ft 0 35 ft2 _ 1 0 0 2 Slab -On -Grade Edge Insulalio O W IC 2 1 It 0 35 ft' _ 1 0 0 3 Slab -On -Grade Edge Insulatio O BATH 6 ft 0 124 ft' — 1 0 0 4SIab-On-Grade Edge Insulatio O TOILET 1 ft 0 24 ft2 — 1 0 0 5SIab-On-Grade Edge Insulatio O LINEN. 4 it 0 20 ft2 — 1 0 0 6 Slab -On -Grade Edge Insulatio LIVING ROOM 34 ft 0 185 ft2 — 1 0 0 7 Slab -On -Grade Edge Insulatio FOYER 7 it 0 70 ft2 __ 1 0 0 8SIab-On-Grade Edge Insulatio DINING ROOM 12 ft 0 132 ft' 1 0 0 9 Slab -On -Grade Edge Insulatio FAMILY ROOM 17 it 0 410 ft2 __ 1 0 0 10SIab-On-Grade Edge Insulatio BREAKFAST 8.2 ft 0 61 W __ 1 0 0 11Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 210 ft2 1 0 0 12SIab-On-Grade Edge Insulatio BATH 3 15 it 0 100.5 ft2 __ 1 0 0 13SIab-On-Grade Edge Insulatio HALLWAY 1 it 0 42 ft' __ 1 0 0 14SIab-On-Grade Edge Insulatio AHU CLST 1 it 0 20 ft' 1 0 0 15SIab-On-Grade Edge Insulatio UTILITY 1 ft 0 68 f12 1 0 0 16SIab-On-Grade Edge Insulatio BATH 2 1 ft 0 54 ft2 1 0 0 17SIab-On-Grade Edge Insulatio CLST 2 2 ft 0 22 W __ 1 0 0 18Slab-On-Grade Edge Insulatio BEDROOM 2 12 ft 0 132 ft2 _ 1 0 0 19SIab-On-Grade Edge Insulatio BEDROOM 3 11 it 0 121 ft2 _ 1 0 0 20SIab-On-Grade Edge Insulatio CLST 3 2 fl 0 12 ftt2 — 1 0 0 21SIab-On-Grade Edge Insulatio LINEN 1 ft 0 4 ft' — 1 0 0 22SIab-On-Grade Edge Insulatio CLST 4 2 fl 0 12 ft' _ 1 0 0 23SIab-On-Grade Edge Insulatio HALL 1 ft 0 16 ft2 1 0 0 24SIab-On-Grade Edge Insulatio BEDROOM 4 24 It 0 143 W — 1 0 0 25SIab-On-Grade Edge Insulatio OWNERS BEDR 39 It 0 224 ft2 1 0 0 5/22120202:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2547 ft2 0 f12 Medium N 0.4 No 0.9 No 0 26.6 ATTIC / `� # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) 0 W IC 1 30 Blown 35 ft- 0.1 Wood 2 Under Attic (Vented) O WIC2 30 Blown 35 ft- 0.1 Wood 3 Under Attic (Vented) O BATH 30 Blown 124 ft2 0.1 Wood 4 Under Attic (Vented) 0 TOILET 30 Blown 24 ft2 0.1 Wood _ 5 Under Attic (Vented) O LINEN 30 Blown 20 W 0.1 Wood _ 6 Under Attic (Vented) LIVING ROOM 30 Blown 185 W 0.1 Wood 7 Under Attic (Vented) FOYER 30 Blown 70 ft2 0.1 Wood 8 Under Attic (Vented) DINING ROOM 30 Blown 132 ft2 0.1 Wood 9 Under Attic (Vented) FAMILY ROOM 30 Blown 410 ft2 0.1 Wood _ 10 Under Attic (Vented) BREAKFAST 30 Blown 61 ft2 0.1 Wood 11 Under Attic (Vented) KITCHEN 30 Blown 210 W 0.1 Wood 12 Under Attic (Vented) BATH 3 30 Blown 101 f12 0.1 Wood _ 13 Under Attic (Vented) HALLWAY 30 Blown 42 ft2 0.1 Wood 14 Under Attic (Vented) AHU CLST 30 Blown 20 ft2 0.1 Wood 15 Under Attic (Vented) UTILITY 30 Blown 68 ft2 0.1 Wood _ 16 Under Attic (Vented) BATH 2 30 Blown 54 ft2 0.1 Wood 17 Under Attic (Vented) CLST 2 30 Blown 22 W 0.1 Wood 18 Under Attic (Vented) BEDROOM 2 30 Blown 132 ft2 0.1 Wood 19 Under Attic (Vented) BEDROOM 3 30 Blown 121 W 0.1 Wood 20 Under Attic (Vented) CLST 3 30 Blown 12 ft2 0.1 Wood 21 Under Attic (Vented) LINEN 30 Blown 4 ft2 0.1 Wood 22 Under Attic (Vented) CLST 4 30 Blown 12 ft2 0.1 Wood _ 23 Under Attic (Vented) HALL 30 Blown 16 ft2 0.1 Wood 24 Under Attic (Vented) BEDROOM 4 30 Blown 143 ft2 0.1 Wood 25 Under Attic (Vented) OWNERS BEDR 30 Blown 224 ft2 0.1 Wood WALLS ()�f Adjacent To 1AIP11 Type Cavity Width SpaceFt Height In Ar,, Sheathing Framing Solar Below Crnd,o 1 E Exterior Concrete Block - Int Insul 0 WIC 1 4.1 7 0 8 0 56.0 ft2 0 0 0.4 0 2 E Exterior Concrete Block - Int Insul O BATH 4.1 6 0 8 0 48.0 fl2 0 0 0.4 0 _ 3 E Exterior Concrete Block - Int Insul0 LINEN 4.1 4 0 8 0 32.0 ft2 0 0 0.4 0 4 N Exterior Concrete Block - Int InsWVING ROO 4.1 14 0 10 0 140.0 ft2 0 0 0.4 0 5/2212020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 5 E Exterior Concrete Block - Int InsLIVING ROO 4.1 14 0 10 0 140.0 ft' 0 0 0.4 0 _ 6 W Exterior Concrete Block - Int Ins41VING ROO 4.1 6 0 10 0 60.0 ft' 0 0 0.4 0 _ 7 N Exterior Concrete Block - Int Insul FOYER 4.1 7 0 10 0 70.0 fV 0 0 0.4 0 8 N Exterior Concrete Block - Int InsDINING ROO 4.1 11 0 10 0 110.0 ft2 0 0 0.4 0 9 E Exterior Concrete Block - Int InsDINING ROO 4.1 1 0 10 0 10.0 ft' 0 0 0.4 0 _ 10 N Garage Frame - Wood DINING ROO 11 1 0 10 0 10.0 it- 0 0.1 0.4 0 _ 11 S Exterior Frame - Wood FAMILY ROO 19 17 0 10 0 170.0 ft' 0 0.1 0.4 0 12 BE Exterior Frame - Wood BREAKFAST 19 4 3 10 0 42.5 ft2 0 0.1 0.4 0 13 S Exterior Frame - Wood BREAKFAST 19 4 0 10 0 40.0 ft' 0 0.1 0.4 0 _ 14 E Exterior Frame - Wood BATH 3 19 6 0 8 0 48.0 ft' 0 0.1 0.4 0 15 S Exterior Concrete Block - Int Insul BATH 3 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 16 N Garage Frame - Wood UTILITY 11 8 0 8 0 64.0 f12 0 0.1 0.4 0 _ 17 W Garage Frame - Wood UTILITY 11 2 0 8 0 16.0 ft2 0 0.1 0.4 0 18 N Garage Frame - Wood BATH 2 11 6 0 8 0 48.0 it- 0 0.1 0.4 0 _ 19 W Exterior Concrete Black - Int Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 20 N Garage Frame - Wood CLST 2 11 11 0 8 0 88.0 ft2 0 0.1 0.4 0 21 E Garage Frame - Wood CLST 2 11 2 0 8 0 16.0 ft2 0 0.1 0.4 0 _ 22 W Exterior Concrete Block - Int InsBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0 _ 23 W Exterior Concrete Block - Int InsBEDROOM 3 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 24 W Exterior Concrete Block - Int Insul CLST 3 4.1 2 0 a 0 16.0 ft2 0 0 0.4 0 _ 25 W Exterior Concrete Block - Int Insul CLST 4 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 _ 26 S Exterior Concrete Block - Int InsBEDROOM 4 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 27 W Exterior Concrete Block - Int InsBEDROOM 4 4.1 13 0 8 0 104.0 IF 0 0 0.4 0 _ 28 E Exterior Concrete Block - Int InsOWNERS BE 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 29 S Exterior Concrete Block - Int InsOW NERS BE 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 30 W Exterior Frame - Wood OWNERS BE 19 9 0 8 0 72.0 ft2 0 0.1 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 NE Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft2 2 it 0 in 1 it 4 in None None 2 N 4 Metal Low-E Single Yes 0.65 0.25 N 14.6 ft2 2 ft 0 in 1 it 4 in None None 3 N 4 Metal Low-E Single Yes 0.65 0.25 N 15.0 f12 2 It 0 in 1 ft 4 in None None 4 E 5 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft2 2 ft 0 In 1 it 4 in None None 5 N 7 Metal Low-E Single Yes 0.65 0.25 N 10.0 W 7 ft 0 in 1 ft 4 in None None 6 N 7 Metal Low-E Single Yes 0.65 0.25 N 13.3 IF 7 it 0 in 1 it 4 in None None _ 7 N 8 Metal Low-E Single Yes 0.65 0.25 N 36.0 1? 2 ft 0 in 1 ft 4 in None None 8 S 11 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft2 8 ft 8 in 1 fl4 in None None 5/22/2020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 9 10 11 _ 12 13 14 15 16 17 S 11 Metal SE 12 Metal S 13 Metal E 14 Metal W 22 Metal W 23 Metal S 26 Metal S 29 Metal W 30 Metal Low-E Single Low-E Single Low-E Single Low-E Single Law-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.25 N 17.8 ft2 8 ft 8 in 0.65 0.25 N 8.0 ft' 6 ft 0 in 0.65 0.25 N 12.0 ft2 6 It 0 In 0.65 0.25 N 15.6 ft' 6 It 0 in 0.65 0.25 N 15.0 ft2 2 ft 0 in 0.65 0.25 N 15.0 ft' 2 ft 0 in 0.65 0.25 N 15.0 ft' 2 It 0 in 0.65 0.25 N 30.0 ft2 2 It 0 in 0.65 0.25 N 17.8 ft' 4 ft 0 in 1 ft 4 in 1 ft 4 in 1 It 4 in 1 It 4 in 1 ft 4 in 1 It 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in None None None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 696 ft2 696 ft2 30 ft 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000398 2374.4 130.35 245.14 .144 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 41.5 kBtu/hr 1245 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cerl # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None fl2 5/22/2020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CMECKI IRT RFPnRT DUCTS / ---- Supply -- ---- Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft' Attic 17 ft2 Default Leakage AHU CLST (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Venting Jan Feb Mar r Ma MayrX� Jun [ j Jul r [ Aug fX� [ ] Sep jr)C,) Nov Dec [ JX Apr May lXJ Jun 11 Jul I Aug 11 Sep Oct X[ ] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 W 0 ft 0.3 O W IC 1 Default(8 lbs/sq.ft. ft2 ft 0.3 OWIC2 Default(B Ibs/sq.ft. ft' ft 0.3 O BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 O TOILET Default(8 Ibs/sq.ft. ft2 ft 0.3 O LINEN Default(8 Ibs/sq.ft. ft' ft 0.3 LIVING ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibslsq.ft. ft2 ft 0.3 DINING ROOM Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 lbs/sq.ft. ft' ft 0.3 BREAKFAST Default(B Ibslsq.ft. ft' ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(81bs/sq.ft. fl2 ft 0.3 HALLWAY Default(B Ibslsq.ft. k2 ft 0.3 AHU CLST Default(B lbs/sq.ft. ft' ft 0.3 UTILITY Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibslsq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 3 Default(B Ibs/sq.ft. f12 ft 0.3 CLST 3 Default(81bs/sq.ft. ft. ft 0.3 LINEN Default(8 Ibs/sq.ft. fR ft 0.3 CLST 4 Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/s .ft. f12 ft 0.3 OWNERS BEDRO 5/2212020 2:41 PM EnergyGaugerst USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: ST LUCIE COUNTY Permit #: Job Information ' Builder: ADAMS HOMES Community: Lot: NA Address: 8108 AMALFI CIRCLE City: PORT ST LUCIE State: FL Zip: 34951 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The huilaing:ordwelling unit shall be1ested and verified as having an air leakage rate of not exceeding pair changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and'2:' 0 PERFORMANCE or ERI METHOD -The building or dwelling unit shall'be tested and verified ashaving an air leakage rate of not exceeding the selected ACH(50)value, as shown c Form R405-2017 (Performance) a R406-2017 (ERI), section labeled as infiltration, sub -section ACH50. ACH(50) specked on Form R405-2017-Energy Calc (Performance). or R406-2017.(ERIf: x 60 - 20352 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ❑ PASS 0 Code software calculated ❑ When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. A written reportof the results of the test shall be signed by the party conducting the test and provided to thecode official . Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, Intake, makeup air, back draft and Flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company ; Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 5/22/2020 2:42:10 PM EnergyGaugeS USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: ADAMS HOMES- 2265 MODEL A Builder Name: ADAMS HOMES Street: 8108 AMALFI CIRCLE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE , FL, 34951 Permit Number: U Owner: Jurisdiction: ST LUCIE COUNTY i Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with the The Insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per Inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. I Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the botto to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electricallphone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -Floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 5/22/2020 2:41 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 41.5 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2277 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c) Area 7c. 289.0 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat. Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wpod, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 19.0 e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec0/o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: ' Address of New Home: 8108 AMALFI CIRCLE City/FL Zip: PORT ST LUCIE, FL 34951 5/22/2020 2:41:32 PM EnergyGaugeg) USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1