HomeMy WebLinkAboutProduct approvals, underlayments, Resisto7/27/2020 Florida Building Code Online
Business & Professional Regulation
BC15 Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact us BCIS Site Map Links Searcn
doFlorida r
ddw.e`ProductApproval
4�. �f USER: Public User
go
Product Approvai Menu n Product or Application Search n Agplication List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL2569-R19
Revision
2017
Approved
Soprema, Inc. (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memath ieu@soprema.ca
Marc -Etienne Mathieu
rnemathieu@soprema.ca
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 0000o
(819) 478-2400 Ext3327
memath ieu@soprema.ca
Jean -Francois Cote, Ph.D,
1640 rue Haggarty
Drummondville
(888) 811-3145
jfcote@soprema.ca
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert I M. Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
04/10/2023
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
FL2569 R19 _COI 2020 01 COI IIEMiNEN._pdf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2008
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL1897
2012
https:lifloridabuilding.org/pripr_app_dtl,aspx?param=wGEVXQwtDgsKQFF-nckBlO8Erxl LJd3xYIR3WFL46CdQuQllynvE6gkA%3d%3d 1/2
7/27/2020
Florida Building Cade Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/09/2020
Date Validated 04/09/2020
Date Pending FBC Approval 04/14/2020
Date Approved 06/02/2020
of
FL # Model, Number or Name
2569.1 Soprema Roof Underlayments
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Section 5 for Limits of Use. 2,) The
design pressure noted herein pertains to underlayment systems
used beneath adhesive -set tile systems. Refer to ER Section
5.6.4 for details.
Description
Self adhering roof underlayments
Installation Instructions
FL2569 R19 II 2020 04 0 INA E FL2569-R19.p�f
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL2 69 Rl _AE 2020 04 06 FINAL ER FL2569-R19.p�f
Created by Independent Third Party: Yes
Sack Next
Contact Us :: 2ha1 Bla1r $tone Road, Taifahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. fopydght 2007-2013 State of Fiorida :: Privacyement :: Apcessibility_�tatement :: Refund Statement
Under Florida law, email addresses are public records. If you do rot want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail, if you have any questions, please contact 850,487.1395. *Pursuant to Section 455.275(t),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for officiai communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click re .
Product Approval Accepts:
M �v ® F!`�
Credit Card
Safe
https:lfflor€dabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsKQFEnckBI08ErxlUd3xYIR3WFL46CdQu011ynvE6gkA%3dn/o3d 2/2
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #l13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONPO.
Soprema, Inc. Evaluation Report S18010.06.09-1117
1640 rue Haggerty FL2569-R19
Drummondville, Quebec J2C 5P8 Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 17: 04/06/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 611 Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words " NEMOI etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
-
...3,,,,,
Robert J.M. Nieminen, P.E.
=' '`''` '=u;-
��� _.,..� ��i c ; The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983
Nieminen, P.E. on 04/06/2020. This does not serve as an
='.,.•,'a electronically signed document
CERTIFICATION OF INDEPENDENCE:
1, NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.F, does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
Oc 2019 NEW ETC, LLC
ONEMOJetc.
Product Category: Roofing
Sub -Category: U nderlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 6tn Edition (2017) Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, 1507.2.9.2, R905.1.1,
Physical Properties
ASTM D1970
2015
R905.2.8.2
1507.3.3, R905.3.3
Physical Properties
FRSA/TRI April 2012
2012
FRSA/TRI April 2012 (04-12)
Physical Properties
ASTM D6163
2008
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM D1970 / TAS 110 (QC)
S31370.03.10-1-R1
04/07/2010
ERD (TST6049)
I=RSA/TRI 04-12 (OH)
S11150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970 (OH)
S37210.11.11
11/09/2011
ERD (TST6049)
ASTM D1970 (MS)
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 (BC)
S44870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D1970 (QC)
544870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.144
04/10/2014
ERD (7ST6049)
ASTM D1970 (OH)
S40540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520,04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-R1
06/07/2017
M-D (CER1592)
HVHZ Compliance
18-0329.03
06/28/2018
ICC-ES (EVL2396)
2015 18C Compliance
ESR-1524
03/01/2017
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC)
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
MEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-19-5SLAP-01.A.R2
02/10/2020
NFMO (TST6049)
Peel adhesion (existing underlayments)
4j-S0PC-I9-SSUDL-04.A
03/12/2020
FRI (TSTS878)
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
07/18/2017
NEMO ETC, LLC Evaluation Report S18010.06.09-R17
Certificote of Authorization #32455 6Y" EDITION (2017) FBC PION-HVHZ EVALUATION FL2569-R19
Soprema Roof Underlayments Revision 17: 04106/2020
Page 2 of 8
4. PRODUCT DESCRIPTION:
Product
4.1 Lastobond TU HT
4.2 J Lastobond Shield
4.3 RESISTO SA SMOOTH PLY
40
4.4 Lastobond Shield HT
4.5 1 Lastobond Pro HT-N
Specification
ASTM D1970 and
FRSA/TRI April 2012
ASTM D1970
ASTM D1970
ASTM D1970
Plant(s)
Gulfport, MS
Drummondville, QC
Drummondville, QC
Drummondville, QC
ASTM D1970 J Drummondville, QC
4.6
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
4.7
EnviroShieid
ASTM D1970
Drummondville, QC
4.8
Lastobond 195
ASTM D1970
Gulfport, MS
Wadsworth, OH
4.9
ASTM D1970
Gulfport, MS
FLastobondaves
heet
Wadsworth, OH
4.10
o
ASTM D1970
Drummondville, Qc
Gulfport, MS
Wadsworth, OH
4.11
Lastobond Smooth Seal
ASTM D1970
Gulfport, MS
HT
Wadsworth, OH
4.12
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
Smooth Seal HT
Wadsworth, OH
4.13
RESISTO LB1236
ASTM D1970
Drummondville, QC
Gulfport, MS
Wadsworth, OH
4. 4
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
Eave & Valley Protector
Gulfport, MS
4.15
SRS TopShield ICE &
ASTM D1970
Wadsworth, OH
Drummondville, QC
WATER DEFENDER
Gulfport, MS
Wadsworth, OH
.16
RESISTO LB1244
ASTM D1970
Drummondville, QC
Gulfport, MS
Wadsworth, OH
4.17
Colphene FR GR
TM D1970 and
FFRSAITRI
Gulfport, MS
April 2012
Wadsworth, OH
ONEMOjetc.
Description
self -adhering, non -woven polyester fabric surfaced,
SBS modified bitumen roof underlayment
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
self -adhering, woven polyethylene surfaced, SBS
Modified bitumen roof underlayment
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
self -adhering, woven polyethylene surfaced, SBS
Modified bitumen roof underlayment available in
two widths; 36 and 45 inch
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
self -adhering, glass -mat reinforced, sand -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, sand -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, sand -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, film -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, film -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, sand -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, sand -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, sand -surfaced,
SBS modified bitumen roof underlayment
self -adhering, glass -mat reinforced, sand -surfaced,
SBS modified bitumen roof underlayment
self -adhering, fiberglass reinforced, granule -
surfaced, SBS modified bitumen roof underlayment
MEMO ETC, LLC
Evaivation Report $18010.06.09-R17
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVH2 EVALUATION
FL2569-R19
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 3 of 8
S. LIMITATIONS: ONEmoletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluations Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Wood or
Asphalt Nail -On Foam -On :State orUnderlayment Metal Composite osite
Shingles Tile Tile Shakes & pShingles ate
Lastobond TU HT Yes Yes Yes
See 5.5.1 Yes Yes Yes
Lastobond Shield / Pro HT N /
RESISTO SA SMOOTH PLY 40 Yes No No No Yes Yes
Lastobond Shield HT / Pro HT-S Yes No No Yes Yes Yes
Enviro5hield Yes No No Yes Yes Yes
Lastobond Eaves Protection Sheet /
Lastobond 195 Yes No No No Yes Yes
Lastobond FCO / RESISTO LB1236,
Grip -Rite Eave & Valley Protector /
TopShield ICE & WATER DEFENDER / Yes No Na No Yes Yes
RESISTO LB1244
Lastobond Smooth Seal HT/ Grip -
Rite Smooth Seal HT Yes No No Yes Yes Yes
Colphene FR GR Yes Yes No No Yes Yes
5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Underlayment Adhesive Florida Product Approval
Lastobond TU HT Dupont TILE BONDTM FL22S25
ICP Adhesives Poiyset® AH-160 FL6332
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
MEMO ETC, LLC Evaluation Report S18010.06,09-R17
Certificate of Authorization #32455 6TH EDITION (701.7) FBC NON-HVHZ EVALUATION FL2569-R19
Soprema Roof Underlayments Revision 17. 04/06/2020
Page 4 of 8
ONEMOjetc.
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS
Underlayment
Primer
Substrates
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
(Optional) ASTM D41,
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
Elastocol Stick, Elastocol Stick
plywood, OSB, Southern Yellow
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection
Zero
Pine (SYP)
Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER
DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT or
ASTM D41
structural concrete
Grip -Rite Smooth Seal HT
Colphene FIR GR
(Optional) ASTM D41
Plywood
ASTM D41
structural concrete
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond shield HT, Lastobond Pro HT-S,
EnviroShield, Lastobond TU HT, Lastobond Eaves Protection
Dens Deck Prime; SECUROCiC
Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236,
(Optional) Elastocol Stick Zero
Gypsum -Fiber Roof Board;
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER
ASTM D226, Type I or 11 feit;
DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT,
Sopra-G; Modified Sopra-G
Grip -Rite Smooth Seal HT or Colphene FR GR
Existing sand -surfaced, glass-
RESISTO LB1236, Grip -Rite Eave & Valley Protector or
fiber surfaced, mineral -surfaced
TopShield ICE & WATER DEFENDER
RESISTO EXTERIOR PRIMER
or film -surfaced roof
underlayment*
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite
Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
5.6.1 Soprema recommends priming with Elastoco[ Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering under[ayment
5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached
per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix I7, Testing Application Standard TAS 114, Appendix J or UL1.$97.
5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum
codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base sheet shall be
attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein.
5.6.5 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012 (04-12) or FBC 1609 for determination of design wind pressures.
MEMO ETC, LLC Evaluation Report 518010.06.09-1117
Certificate of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1119
Soprema Roof Underlayments Revision 17: 04/06/2020
Page 5 of 8