Loading...
HomeMy WebLinkAboutProduct approvals, underlayments, Resisto7/27/2020 Florida Building Code Online Business & Professional Regulation BC15 Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact us BCIS Site Map Links Searcn doFlorida r ddw.e`ProductApproval 4�. �f USER: Public User go Product Approvai Menu n Product or Application Search n Agplication List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL2569-R19 Revision 2017 Approved Soprema, Inc. (Canada) 1640 rue Haggarty Drummondville, NON -US 00000 (819) 478-2400 memath ieu@soprema.ca Marc -Etienne Mathieu rnemathieu@soprema.ca Marc -Etienne Mathieu 1688 Jean-Berchmans-Michaud Drummondville, NON -US 0000o (819) 478-2400 Ext3327 memath ieu@soprema.ca Jean -Francois Cote, Ph.D, 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert I M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 04/10/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2569 R19 _COI 2020 01 COI IIEMiNEN._pdf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2008 FM 4474 2011 FRSA/TRI April 2012 (04-12) 2012 UL1897 2012 https:lifloridabuilding.org/pripr_app_dtl,aspx?param=wGEVXQwtDgsKQFF-nckBlO8Erxl LJd3xYIR3WFL46CdQuQllynvE6gkA%3d%3d 1/2 7/27/2020 Florida Building Cade Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/09/2020 Date Validated 04/09/2020 Date Pending FBC Approval 04/14/2020 Date Approved 06/02/2020 of FL # Model, Number or Name 2569.1 Soprema Roof Underlayments Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150 Other: 1.) Refer to ER Section 5 for Limits of Use. 2,) The design pressure noted herein pertains to underlayment systems used beneath adhesive -set tile systems. Refer to ER Section 5.6.4 for details. Description Self adhering roof underlayments Installation Instructions FL2569 R19 II 2020 04 0 INA E FL2569-R19.p�f Verified By: Robert Nieminen, P.E. PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2 69 Rl _AE 2020 04 06 FINAL ER FL2569-R19.p�f Created by Independent Third Party: Yes Sack Next Contact Us :: 2ha1 Bla1r $tone Road, Taifahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. fopydght 2007-2013 State of Fiorida :: Privacyement :: Apcessibility_�tatement :: Refund Statement Under Florida law, email addresses are public records. If you do rot want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail, if you have any questions, please contact 850,487.1395. *Pursuant to Section 455.275(t), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for officiai communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click re . Product Approval Accepts: M �v ® F!`� Credit Card Safe https:lfflor€dabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsKQFEnckBI08ErxlUd3xYIR3WFL46CdQu011ynvE6gkA%3dn/o3d 2/2 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #l13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATIONPO. Soprema, Inc. Evaluation Report S18010.06.09-1117 1640 rue Haggerty FL2569-R19 Drummondville, Quebec J2C 5P8 Canada Date of Issuance: 06/15/2009 (819) 478-2400 Revision 17: 04/06/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 611 Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words " NEMOI etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: - ...3,,,,, Robert J.M. Nieminen, P.E. =' '`''` '=u;- ��� _.,..� ��i c ; The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 Nieminen, P.E. on 04/06/2020. This does not serve as an ='.,.•,'a electronically signed document CERTIFICATION OF INDEPENDENCE: 1, NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.F, does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Oc 2019 NEW ETC, LLC ONEMOJetc. Product Category: Roofing Sub -Category: U nderlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6tn Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, 1507.2.9.2, R905.1.1, Physical Properties ASTM D1970 2015 R905.2.8.2 1507.3.3, R905.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012 (04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) ASTM D1970 / TAS 110 (QC) S31370.03.10-1-R1 04/07/2010 ERD (TST6049) I=RSA/TRI 04-12 (OH) S11150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 (OH) S37210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 (MS) S37210.12.11 12/01/2011 ERD (TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013 ERD (TST6049) FRSA/TRI 04-12 (MS) S43530.02.14-1-R1 02/21/2014 ERD (TST6049) ASTM D1970 (BC) S44870.04.14-2 04/02/2014 ERD (TST6049) ASTM D1970 (QC) 544870.04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) S44870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.144 04/10/2014 ERD (7ST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520,04.14 04/27/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D (CER1592) HVHZ Compliance 18-0329.03 06/28/2018 ICC-ES (EVL2396) 2015 18C Compliance ESR-1524 03/01/2017 NEMO (TST6049) ASTM D1970 / TAS 110 (QC) SOPC-SC8970.08.15-RI 04/25/2018 NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 MEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging 4p-DOW-19-5SLAP-01.A.R2 02/10/2020 NFMO (TST6049) Peel adhesion (existing underlayments) 4j-S0PC-I9-SSUDL-04.A 03/12/2020 FRI (TSTS878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 07/18/2017 NEMO ETC, LLC Evaluation Report S18010.06.09-R17 Certificote of Authorization #32455 6Y" EDITION (2017) FBC PION-HVHZ EVALUATION FL2569-R19 Soprema Roof Underlayments Revision 17: 04106/2020 Page 2 of 8 4. PRODUCT DESCRIPTION: Product 4.1 Lastobond TU HT 4.2 J Lastobond Shield 4.3 RESISTO SA SMOOTH PLY 40 4.4 Lastobond Shield HT 4.5 1 Lastobond Pro HT-N Specification ASTM D1970 and FRSA/TRI April 2012 ASTM D1970 ASTM D1970 ASTM D1970 Plant(s) Gulfport, MS Drummondville, QC Drummondville, QC Drummondville, QC ASTM D1970 J Drummondville, QC 4.6 Lastobond Pro HT-S ASTM D1970 Drummondville, QC 4.7 EnviroShieid ASTM D1970 Drummondville, QC 4.8 Lastobond 195 ASTM D1970 Gulfport, MS Wadsworth, OH 4.9 ASTM D1970 Gulfport, MS FLastobondaves heet Wadsworth, OH 4.10 o ASTM D1970 Drummondville, Qc Gulfport, MS Wadsworth, OH 4.11 Lastobond Smooth Seal ASTM D1970 Gulfport, MS HT Wadsworth, OH 4.12 PrimeSource Grip -Rite ASTM D1970 Gulfport, MS Smooth Seal HT Wadsworth, OH 4.13 RESISTO LB1236 ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH 4. 4 PrimeSource Grip -Rite ASTM D1970 Drummondville, QC Eave & Valley Protector Gulfport, MS 4.15 SRS TopShield ICE & ASTM D1970 Wadsworth, OH Drummondville, QC WATER DEFENDER Gulfport, MS Wadsworth, OH .16 RESISTO LB1244 ASTM D1970 Drummondville, QC Gulfport, MS Wadsworth, OH 4.17 Colphene FR GR TM D1970 and FFRSAITRI Gulfport, MS April 2012 Wadsworth, OH ONEMOjetc. Description self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch self -adhering, woven polyethylene surfaced, SBS Modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, SBS Modified bitumen roof underlayment available in two widths; 36 and 45 inch self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment self -adhering, fiberglass reinforced, granule - surfaced, SBS modified bitumen roof underlayment MEMO ETC, LLC Evaivation Report $18010.06.09-R17 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVH2 EVALUATION FL2569-R19 Soprema Roof Underlayments Revision 17: 04/06/2020 Page 3 of 8 S. LIMITATIONS: ONEmoletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluations Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Wood or Asphalt Nail -On Foam -On :State orUnderlayment Metal Composite osite Shingles Tile Tile Shakes & pShingles ate Lastobond TU HT Yes Yes Yes See 5.5.1 Yes Yes Yes Lastobond Shield / Pro HT N / RESISTO SA SMOOTH PLY 40 Yes No No No Yes Yes Lastobond Shield HT / Pro HT-S Yes No No Yes Yes Yes Enviro5hield Yes No No Yes Yes Yes Lastobond Eaves Protection Sheet / Lastobond 195 Yes No No No Yes Yes Lastobond FCO / RESISTO LB1236, Grip -Rite Eave & Valley Protector / TopShield ICE & WATER DEFENDER / Yes No Na No Yes Yes RESISTO LB1244 Lastobond Smooth Seal HT/ Grip - Rite Smooth Seal HT Yes No No Yes Yes Yes Colphene FR GR Yes Yes No No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive Florida Product Approval Lastobond TU HT Dupont TILE BONDTM FL22S25 ICP Adhesives Poiyset® AH-160 FL6332 'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance MEMO ETC, LLC Evaluation Report S18010.06,09-R17 Certificate of Authorization #32455 6TH EDITION (701.7) FBC NON-HVHZ EVALUATION FL2569-R19 Soprema Roof Underlayments Revision 17. 04/06/2020 Page 4 of 8 ONEMOjetc. 5.6 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS Underlayment Primer Substrates Lastobond Shield, Lastobond Pro HT-N, RESISTO SA (Optional) ASTM D41, SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Elastocol Stick, Elastocol Stick plywood, OSB, Southern Yellow EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Zero Pine (SYP) Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT or ASTM D41 structural concrete Grip -Rite Smooth Seal HT Colphene FIR GR (Optional) ASTM D41 Plywood ASTM D41 structural concrete Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Dens Deck Prime; SECUROCiC Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, (Optional) Elastocol Stick Zero Gypsum -Fiber Roof Board; Grip -Rite Eave & Valley Protector, TopShield ICE & WATER ASTM D226, Type I or 11 feit; DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT, Sopra-G; Modified Sopra-G Grip -Rite Smooth Seal HT or Colphene FR GR Existing sand -surfaced, glass- RESISTO LB1236, Grip -Rite Eave & Valley Protector or fiber surfaced, mineral -surfaced TopShield ICE & WATER DEFENDER RESISTO EXTERIOR PRIMER or film -surfaced roof underlayment* * Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.6.1 Soprema recommends priming with Elastoco[ Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering under[ayment 5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix I7, Testing Application Standard TAS 114, Appendix J or UL1.$97. 5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base sheet shall be attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein. 5.6.5 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. MEMO ETC, LLC Evaluation Report 518010.06.09-1117 Certificate of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1119 Soprema Roof Underlayments Revision 17: 04/06/2020 Page 5 of 8