HomeMy WebLinkAbout2006-0869 - REVISIONL�siWne;MW.Professional Regulation
VN Mt'AIE A appR p,CSYDM1M1 tlr kMf
da
Product Approaral
d b USER: Public Wer
Pyr 9y1[9ppro I M a pmluR
or Peo o[ > poo a > LpplkaUon pW11
FL #
FL14312-R30
Application Type
Revision
Code Version
2012
Application Status
Approved
Comments
Archived
Product Manufacturer
Boal Roofing
Address/Phone/Email
7575 Irvine Center Drive
Suite 100
Irvine, CA 92618
(801) 380-6091
RobinAndersombl oral.com
Authorized Signature
Thomas Jemmett
thomica jammettEsboral.com
Technical Representative
Adrian Cooper
Address/Phone/Email
135 NW 20th Street
Boca Raton, FL 33431
(954) 520-5461
acoopeerilminiedifetile.com
Quality Assurance Representative
Address/Phone/Email
Category
Roofing
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a
Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florlda Engineer or Architect Name who developed the
Robert J. M. Nieminen
Evaluation Report
Florida License
PE -59166
Quality Assurance Entity
UL LLC
Quality Assurance Contact Expiation Date
04/30/2023
Validated By
John W. Rnezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
FL14312 R10 COI 2018 01 COI NIEMINEN gf
Referenced Standard and Year (of Standard)
£tandand
Year
ASTM D1920
2015
FRSA/TRI(April 2012) 04-12
2012
UL1892
2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/12/2018
Date Validated 10/15/2018
Data Pending FIC Approval 10/22/2018
Data Approved 12/11/2018
Summa a Products
FL # Model, Number or Name
Description
14317.1 Banal Roof Underlayments
Roof untledayments for use In prepared roof assemblies
limits of use
Installation Instructions
Approved for use In HVHZ: No
H-14317 RSO II 2018 10 HoldR B d 1 ymen[s Ft143ll-
Approved for use outside HVHZ: Yes
glq,pol
Impact Resistant: N/A
Verified By: Robert 1. M. Nleminen PE - 59166
Design pressure: +N/q/-210
Created by Independent Third Party: Yes
tither: 1.) The design pressure In this application
EvaluMion Reports
pertains m a particular undedaynnent system for use
R14317 R10 AE 2018 10 FINAL ER BO0.e tl yments FL1431J-
under foam -on tile systems. Refer to ER Section
R1O a f
5.6.4. 2.) Refer to ER Section 5 for Limits of Use.
Created by Independent Third Party: Yes
exb Q
Canna (c ,no 850-fo eN
TeeSore M ndideban We. employer, of flontla :; prMwSn[eme ;:q �•xxa NSnkdn :: g{jypp 5te@meM
email adaresse: arc public remN. If you do M
wMN can be mnaee avadffilerto the public. ro didaunene If Wu are a moname
product Avl-va1 exceeds:
®W1oKw] ®
Credit Card
Safe
NEORECta.
ceniscme o)autnoi:onon »alas
353 Christian Street, Unit fl13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATIONr'
Boral Roofing Evaluation Report M35710.12.10-R1I
7575 Irvine Center Drive, Suite 100 FL14317-R30
Irvine, CA. 92618 Date of Issuance: 22/21/2010
(602) 269-2288 Revision 11: 10/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Cade, Residential Volume. The products
described herein have been evaluated for compliance with the 6m Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance Or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOJetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by: --
0uiti P-
Robert J.M. Nieminen, P.E. The rauimaeseal splxanogWas authorizer by Mhen
Florida Registmtion No. 59166, Florida DCA ANE1983 v......,.; Member, P.E.onvo/1Z/2018. miadoesnmumasan
sleormuall, came] document
Ce"FIGTIX! OF I NDEPENeFNU:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is notowned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved In the approval process of the
Product.
5. This is a building code evaluation. Neither NEMO ETC, LLC not Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEIVIOletc.
ROOFING COMPONENT EVALUATION:
a•
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Banal Roofing, have demonstrated
compliance with the following sections of the 6'^ Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
2. STANDARDS:
Section Pro le Standard year
1504.3.1 Wind Uplift UL1897 2012
1507.1.I,T3507.1.1, Physical Properties ASTM D1970 2015
1507.2.9.2
1507.3.3 Physical Properties FRSA/TRI April 2012(04-12) 2012
NEMO ETC, LLC EvalYrtlon Report M35]3010 -R11
Certirym[eyAUMorvadon P320.55 61°EDITION (2417)FBC NDN-XVM2 EVALUATION FL1433431]-RSO
Bomil Roof Underlayments; (602) 2693288 Revision 11:10/12/2818
Pap 2 of 8
Entity
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
M36790.07.11
09/30/2011
ERD (TST 6049)
Physical Properties
B40380.08.12
08/28/2012
ERD(TST 6049)
Tensile Adhesion/LTA
041420.09.12-2
09/11/2012
ERD(TST 6049)
Adhesion
1141940.09.12
09/13/2012
ERD(TST 6049)
Tensile Adhesion/LTA
847390.07.14-1
07/31/2014
FED(TST 6049)
Tensile Adhesion/LTA
847390.09.14
09/04/2014
OC(PDM3838)
Physical Properties
Equivalency statement
11/02/2017
PRI(TST 5878)
ASTM D1970
NEI-031-02-02:REV
10/27/2010
PRI(TST 5878)
ASTM D1970
NEI-029-02-01:REV
12/03/2010
PRI(TST 5878)
Tensile Adhesion/LTA
NEI-046-02-01REV
12/17/2010
PRI(TST 5878)
FRSA/TRI April 2012
NEI -076-02-01
02/14/2011
PRI(TST 5878)
ASTM D1970
NEI -034-02-02
01/29/2013
PRI(TST 5878)
Wind Uplift
BORR-001-02-01
03/17/2015
PRI(TST 5878)
Wind Uplift
BORR-005-02-01
06/24/2015
PRI(TST 5878)
Tensile Adhesion/LTA
DAPF-002-02-01
03/08/2018
PR1(TST 5878)
ASTM D1970 (adhesion)
OCF-0 3-02-01
10/11/2018
U4 U-C.(QUA 9625)
Quality Assurance
Service Confirmation
Exp.08/21/2020
4.
PRODUCT DESCRIPTION:
4.1
Boral• TileSeal so1e is
a nominal 50 -mil thick, polyester -surfaced, self -adhering
SBS modified bitumen roof
underlayment; meets ASTM D1970.
1/
4.2
Boral• TileSeal"' is a
nominal 60 -mil thick, polyester -surfaced, self -adhering
SBS modified bitumen roof
underlayment, meets ASTM D1970 and FRSA/TRI 04-12.
4.3
Borai• MetalSeal- is
a nominal 60 -mil thick, polyester -surfaced, self -adhering
SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.4
GatorSeal° is a nominal
55 -mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5
Citadel- Plus is a nominal
48 -mil thick, fabric -surfaced, fiberglass
reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer In multi -ply
underlayment systems; meets ASTM D1970.
NEMO ETC, LLC EvalYrtlon Report M35]3010 -R11
Certirym[eyAUMorvadon P320.55 61°EDITION (2417)FBC NDN-XVM2 EVALUATION FL1433431]-RSO
Bomil Roof Underlayments; (602) 2693288 Revision 11:10/12/2818
Pap 2 of 8
ONEMOJetc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data forthe prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives/ underlayment combinations.
1A: ALLOWABLE TILE ADEMSIVE
COMBINATIONS'TABLE
UNDERLAYMENT
TABLE 1:
ROOF COVER OPTIONS
Rmlde Product
UndedaynRNH
halt
Nail -On Tile
Metal Wood Slake,
Slate
FL14506
Shiinngka
DAP Foam Touch 'n Seal StormBond 2 Two -Component
neat
Boral Tile5ea150'n
Yes
No
No
Yes
Yes
Yes
Boral Tile$eall^
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.1)
Boral MetalSeal"T
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.11
GatorSeal
Yes
No
No
No
Yes
Yes
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives/ underlayment combinations.
1A: ALLOWABLE TILE ADEMSIVE
COMBINATIONS'TABLE
UNDERLAYMENT
Adhwhle
Rmlde Product
Underlaymenn
Approval
DAP Foam Touch 'n Seal Sto.Bond Roof The Adhesive
FL14506
Boral TheSeal"T or Boral MetalSealR`
DAP Foam Touch 'n Seal StormBond 2 Two -Component
Polyurethane Roof Me Adhesive
FL2137/
Boral TileSeal"T or BoralMetalSeal"'
Dow TILE BOND'" Roof Tile Adhesive
FU2525
Boral TIIPSealm or Boral MetalSeal"'
ICP Adhesives Polyset°AH-160
FL6332
Boral TileSeal"T or Boral MetalSeal"'
ICP Adhesives Polyseta RTA -1
FL6276
Boral TileSealHT or Boral MetalSeal"'
2 Refer to Tile Manufactures or Adhesive Manufadure/s Florida ProductApprovalfor Overcoming Moment Resistance Performance.
NEMO ETC, LLC EMlOation Report M35710.12.10,R11
.mik,IN PfAHhOn Vdn Moss 6- BERTON (2017) FBC NON-E1VNZ EVALUATION P11017 -RID
Boni Roof UnderlaymenU; 16021269-2288 Revision 11: 10/12/2018
Page 3 of 8
5.6 Allowable Substrates: NNEmojetc.
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 50"r, Boral TileSealHT, Boral MetalSeal'n or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSealHT or Boral MetalSeal':
D OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underloyment installations where the
overlying roof cover is adhesive -set the roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"', Boral MetalSeaIn or GatorSeal:
➢ ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 50'^, Boral TlleSeal"T, Boral MetalSeal"T or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.).
Boral TileSeal"T:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications, FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (0412), Appendix A, Table IA or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure= -1200 post:
Deck: Min. 15/32 -Inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSeal"T,self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1X" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#2 Maximum Design Pressure =-1425 DO:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSeal'^ or Boral MetalSeal"T,self-adhered and back -nailed within the selvedge -edge side laps
using 12 ga. x 134" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
NEMO ETC, LLC Evaluation Report M35n0.12.10-R31
( foot ofAufMdmtron#1U55 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FU4332-RIO
eoral Roof Uoderlayments;(602) 2692288 Revision 11: 10/12/2018
Page 4 of 8
#3 Maximum Design Pressure =-2025ixf: WNEMOletc.
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSealin or Boral MetalSealn,sett-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1Y" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12 -inch o.c.
#4 Maximum Design Pressure= -2100 osf:
Deck: Min. 15/32 -inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK#895ta-Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSealHT or Boral MetalSeal"T, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 3Y." ring shank nails through 32 ga., 1-5/8" diameter tin ups spaced 12 -inch o.c.
#5 Maximum Design Pressure= -1200 f:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Pty: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TleSeaPT or Boral MetalSealn self -adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longer than 30 -days after installation, prior to placement of final roof cover.
Boral TileSeal 501T, Bernal TileSeal' or Boral MetalSeal-shall not be left exposed for longer than 180 -days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
180-d2ys after installation, prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations rFRSA/TRI April 2022(04 -12)1 -
When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
G. INSTALLATION:
6.1 Boral Roof Underlaym Ents shall be installed in accordance with Boral Roofng published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising,
NEMO ETC, LLC Evaluation Report M35]30M.30.1131
CertiAwre yAuthonzo[iw S32455 6" EOMON (2017) FBC NON-HVHZ EVALUATION FU017-RIO
Boni Roof Underlarmenta,(602) 269-3388 R.M.. 11: 30/33/3018
Paae 5 of 8
6.4 Citadel Plus: ®NEMO l etc.
6.4.1 Citadel Plus Is limited to use as a base _--id-14.1 in multi -ply underlayment systems beneath Boral TileSeal SONT,
Boral TIIeSeaIBT or GatorSeal.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1 -inch
diameter plastic or steel cap nails spaced maximum 12 -inch o.c. Overlap successive courses the entire width of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50BT, Boral
TileSealM, Boral MetalSeal'n or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type 11 felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal SORT, Boral
TileSeal"* or GatorSeal.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 B._I Tile5Ba150--,
6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be Installed.
6.5.2 Do not use Boral TileSeal 5011' on roof pitches less than 2:12.
6.5.3 Non -Tile Applications Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by X -inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1 -inch diameter
plastic or steel cap nails spaced maximum 24 -inch D.C. for slopes below 7:12 and maximum 12 -inch o.c. for slopes
7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3 -Inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NEMD ETC, LLC Evalaadon Report M35710.12.10-1111
Certalooteo7AiAhamo0on07455 6'"EDITION (2017)Pat NON-NVNZ EVALUATION FU017-RIO
Boral Roof UnderlaMeMa: (602) 269-2288 Revision 11: 10/12/20M
Page 6 of 8
6.5.4 Non -Tile Applications to Base Sheet ONEMOjetc.
Install ASTM D226, Type II felt in accordance with Cade requirements or install Citadel Plus in accordance with
Boral Roofing published installation Instructions and Section 6.4.
Install Boral TleSeal SORT in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Ye -inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1 -inch diameter
plastic or steel cap nails spaced 24 -inch o.c. for slopes below 7:12 and 12 -inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the black -selvedge area, minimum 3 -Inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside Is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications to Base Sheet
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published Installation instructions and Section 6.4.
Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granulartop surface, rolling the interface into place with a weighted roller.
6.7 Boral TlleSeal- or Boral MetalSeall
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeal"r or Boral MetalSexl"r on roof pitches less than 2:12.
6.7.3 Non -Tile Applications Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically SO to 12 ft. Align the membrane parallel to the roof edge, extending over by Y -inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1 -inch diameter plastic or steel
cap nails spaced maximum 12 -inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3 -inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEMO ETC, LLC Evaluatlon R."n M35710.1i.39-Ril
Cedrfiwh AAulhmlza n02455 e EDITON (2017) FBC NON-NVHI EVALUATION FL39317-R30
Bora] Raof Underle7ments, (603) 269-x388 Revision 11:10/13/2018
Page 7 0 8
6.7.4 Nan -Tile Applications to Base SheeSheet- ONEM(Djetc.
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Rooflng published Installation instructions and Section 6.4.
Install Boral TIleSeal' or Boral MetalSeal' over ASTM D226, Type II felt or Citadel Plus in accordance with Boral
Roofing published Installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened the roofing over 2 -ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is d base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSealei
or Boral MetalSealHT with roof pitches of 2% to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PI.ANTS:
Brentwood, NH
9. a
U4 LLC. — QUA9625; (631) 546-2458; Kanchi.Agrawala-Dokan a(ibul corn
END OF EVALUATION REPORT -
NEW ETC, LLC Evaluation Report 1035710.12.10-1131
cert/pmceo)AurhatrananfiU. 6" EDITION 12017) FBC NON-RVNZ EVALUATION FL 317-R30
Mml 11oaf Undedaymems11602) 103-22M Revision 11: 10/13/2039
Paaeea s
OFFICE USE ONLY:
DATE FILED:
REVISION FEE:
PERMIT # 2000-0889
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-6652
(772) 462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
5309 FORT PIERCE BLVD, FORT PIERCE
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CHANGE SELF -ADHERED UNDERLYAMENT BRAND TO BORN -TILE SEAL HT (FL#14317-R10) INSTEAD OF OWENS CORNING
WEATHERLOCK SPECIALTY
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC1325895
BUSINESS NAME: JA TAYLOR ROOFING INC
QUALIFIERS NAME: KYLE WHITE
ADDRESS: 302 MELTON DR
CITY: FT PIERCE STATE:
PHONE (DAYTIME): 772.466x040
OWNER/BUII.DER INFORMATION:
NAME: N1A
ST. LUCIE CO CERT. #: 23016
FL ZIP: 34992
FAX: 772-488-9397
CITY W V STATE:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: N/A
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX:
SLCCC: 9123109
Revised 06130/17