Loading...
HomeMy WebLinkAboutProduct approvals, DURATION37127f2020 Florida Building Code Online Ff fide r 1 Ik #ri%i_ OF THE L Si=Cf?s=TPRY Professional } Regulation BCIS Home - Log In User Registration Hot Topics Submit Surcharge Stats & Facts Poblications ' Contact Us - , BCIS Site Map Links I Se.=J, Product Approval USER: Public User Product Approvai Menu > product or Application Search > Application List > Application Pi FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Finail Quality Assurance Representative Address/Phone/Email Category Subcategory Comphance Method FL10674-R15 Revision 2017 Approved Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg,keeler@owenscorning.com Greg Keeler greg.l<eeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 rnel.sancrant@ovvenscarnig.com Roofing Asphalt Shingles Ib Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J,M. Nleminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration pate 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL10674 R15 COI 2019 01 COT N EMIN N.pdf tandard ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 Year 2015 2016 2010 2011 Sections from the Code https:llfloridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegIC08ucR6ixEDL76gG32Q9MA%3d%3d 1/2 7/27/2020 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/15/2019 08/15/2019 08/21/2019 10/15/2019 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing Shingles and Starters 3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge shingles Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section S. Installation Instructions FL10674 R15 11 201908 FINAL ER OC ASPHALT SHINGLES FL10674-R15.pdf Verified By: Roberti. M. Nieminen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL�74 R15 AE 2019 Q8 FINAL ER OC ASPHALT SHINGLES FLl 74-R1 .pdf Created by Independent Third Party: Yes Bacic rdext Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-iH24 The State of Florida is an AA/EEO employer. Co2yLl ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used far official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please Provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here . Product Approval Accepts: rT U ® eCh ek Credit Card Safe hops:llfioHdabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahReglCQBucR6ixEDL76gG32Q9MA°/a3d%3d 2/2 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE: TEST CONSULT CERTIFY EVALUATION.O. Owens Corning Evaluation Report 037940.02.12-1110 One Owens Corning Parkway FL10674-R15 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-4-7829 Revision 10: 08/15/2-019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P,E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Evaluation Report consists of pages 1 through 10. Prepared by. - Robert J.M. Nieminen, P.E. The facsimile seal appearing was authorized by Robert Florida Registration No, 59166, Florida DCA ANE1983 Nieminen, P.E. an 08/15/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E, does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEW I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC ROOFING SYSTEMS EVALUATION: ONEMOJetc. 1. SCOPE - Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6t' Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS:2. Section Property Standard Year 1507.2.4, 11905.2.3 Physical Properties ASTM D1970 2015 1507.23, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 3. REFERENCES: Wind Resistance ASTM D7158 2011 Entity Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physica! Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4796126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CERiS92) FBC HVHZ Compliance Various NOAs Various PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2-inch wide x 33-ft 4-inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic' and Supreme' are fiberglass reinforced, 3-tab asphalt roof shingles. Meets ASTM 03462. 4.2.2 Berkshire' are fiberglass reinforced, 4-tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration', TruDefinition Duration', Duration' Premium Cool, TruDefinition® Duration' Designer Color Collection, TruDefinition Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdgel Hip & Ridge Shingles and WeatherGuard® HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate afAuthorization #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 2 of 10 ONEMOIetc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. S.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5_4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones UP to Va,d = 150 mph (V it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating acceptable use in all wind zones up to VaSd = 150 mph (Vast = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. rigure 1: IVllnimum Nailing, Starter Strip Fep unde�¢ym¢nt �� Sei%adhered Weaah«iudng �c� uMerlaym¢M 1� f ndp, drip adge �g< Na�[nntsd WkhVI hrtersrnp qus SsMteating edhesW. iih 6'rempyep iMktmrtatl fl¢lag eav 5laner5atpfWs ovnhangs ewes amasahaa IW-314' Figure 2: Minimum Nailing, Starter Strip Pius NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 3 of 10 ONEMOjetc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck Brig edge r / Underlayment Drip edge Starter Shingle Roll adhered directly to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire* shingles require minimum five (5) nails per shingle. ➢ WeatherGuar& HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic® & Su reme: Normal Mansard or Area pare Wind Areas High Wind desvages y Area pare vientas normalea Areas vientos fuertes 5" Exposure Exposici6n Figure 4: Minimum Nailing, Classic & Supreme (Standard Size) Normal Mansard or Ares para Wind Areas High Wind desysnes y Area pare vientos normalea Areas vientos foertas I,. r ' 2• 5 SM' Exposure Exposici6n Figure S: Minimum Nailing, Classic & Supreme (Metric Size) NEIVIO ETC, LLC Evaluation Report 037940.02.12-1130 Certificate ofAuthorizotion #32455 6"' EDITION Q017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10. 08/15/2019 Page 4 of 10 6.3.1.2 Berkshire": realm strip La Ike de sellador " 8 Y29 Y� 9 ye, BV� i I Figure 6: 5-Nail Pattern, Berkshire ONEMOjetc. Sealant strip La flra de seflador _ • �^^�� ! ��. • • Yet ! a--i...�� ! 8 Vi" 8 Figure 7: 6-Nail Pattern, Berkshire Figure 8: Mansard or Steep Slope Pattern, Berkshire NENIO ETC, LLC Certificate ofAuthorizotion #32455 6T" EDITION (2017) FSC NON-HVHZ EVALUATION Owens Corning Asphalt Roof Shingles Evaluation Report O37940.OZ.12-R10 FL10674-R1S Revision 10: 09/15/2019 Page 5 of 10 ONEMOjetc. 6.3.1.3 Duration® TruDefinition" Duration Duration@ Premium Cool & TruDefinition' Duration® Designer or Collection: �_N�il Ca�•ir.n r.... sou....._ -- - -...-.......... .. t ,-c... I oa-11, ✓ U 1 aliuII 6-Nail Fastening Pattern SureNall®fastentng area Width Nail, Typical 7" 12" 12„ri � ,.�' ___. �.�`�, • Ow eu Cammg Smef .ti�.t'; .. rr118" 5�g" �PtnOR' Figure 10: 6-Nail Pattern, Duration Fastening for Slopes Greater Than 21:12 SWONallJ fastening area width Nail, Typical 1211 12„ f„ p�YCM .�.Orn1n45w¢Nail . • L �'� Nam56t1,VfOJ SL2.Vm ✓1 Oxpllb' ming SvreNa�W • Four f" Spots of Asphalt Roofing Cement Figure 11- Mansard or Steep Slope Pattern, Duration NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authonzation #32455 6=" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphatt Roof Shingles Revision 10: 08/15/2019 Page 6 of 10 63.1.4 TruDefinition®OakridgeO Oakri4gg 4 Nail Pattarn Esquema curt d cJavos t° ,2'. f, !+r - I �, ,2-� 5 518" Exposure Nails 5 519" Exposure Exposfcidn de 55/8pulg. MOW= Expo siddn do 5618pufg. Figure 12: Standard 4-Nail Pattern, Dakridge 6 Nalf Pattern Esquema con 6 davos I 1 12' osure Nails 5 518" Fx p Cfauos 5 519" Exposure Exposicfdrr de 6518pufg. Expo sfckn de S 5/8pufg. Figure 13: 6-Nail Pattern, Dakridge -a--- - Malfbalu W1 ,teep-Mope Pattern, uaKridge IRNEMOjetc. NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate o}Authorization #32455 6"' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 7 of 10 6.3.1.5 WeatherGuarcf0 HP; P4. Up r� 4�OS 5 5i8`paarre fza a�6n da 5 5 9 yu9g. 5 5i8" Btpasbik de 5 M. Figure 15: 6-Nail Pattern, WeatherGuard HP 6 Nail Pattern Esquema con 6 clews Nail 6 10 from bottom of shingle Nye a 6 ii$ pulg. de la 5 5d6" Exposure 6 Fasteners parte inferior de Fa teja Exposlci6n de 5 5;8 ping. 6 sujetadores Four 7" Spots of Asphalt Roof Lament crratrri pants do renmto de tedw de ssfdis de i Pulgada Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP ONEMOjetc. 6.4 HIP & RIDGE SHINGLES: 6.4,1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. Y Berkshire' Hip and Ridge Shingles with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant require minimum two (2) nails per shingle. WeatherGuard' HP Hip and Ridge Shingles and ProEdge® Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. MEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization432455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10. 08/15/2019 Page 8 of 10 ONEMOjetc. 6.4.1.1 BerkshireO Hip & Ridge with Sealant and UuraRid eO Hip & Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction Direction del viento predominance Nails �� A Clavos — -- ! ! I a A 1 I I I ! ! I I I A 8 Exposure Exposki6n ds $ 419 0 rigure it: Isometric view, Berkshire and DuraRidge 6.4-1.2 WeatherGuardO HP Hip & Ridge Shingles: Fig. A Prevailing Nand Direction �y Nal Is p 44 � I I I I I I I I I Exposure rigure iy: isometric view, WeatherGuard HP Hip & Ridge Fig. B Top View Vista superior It 1 I I Nail 25/g Clam • Owens Coming SureNail' • f I I+ CI; a+ �I C I I 4 1 2", Pigure its: Plan View, Berkshire and DuraRidge Fig. C Hip & Ridge Shingle Fastening To p Vlew Nails Nails 7" 2" V 1" Exposure 12" Figure 20: Plan View, WeatherGuard HP Hip & Ridge NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate afAutharization ##32455 GT" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RI5 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 9 of 10 6.4.1.3 ProEdge" Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip 4OC'�" 6" Exp6sure Fasten 71ii" Cover Exposed i`35tener5 with RGof Cement Figure 21: Isometric View, ProEdge ONEMOjetc. Standard Fastening Pattern Y— * 2 12' Sealant 7lh.' t f" Exposure Figure 22: Plan View, ProEdge 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. PRI Construction Materials Technologies, LLC— QUA9110; 1Q1 621-5777; bwilson@pricmt,com - END OF EVALUATION REPORT - NEW ETC, LLC Evaluation Report 037940.02.12-1110 Certificate afAuthorization #32455 67" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Page 10 of 10