HomeMy WebLinkAboutHVAC Energy CalcsProject Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
DIEDERICH AND CHRISTIE HUECK
HUECK RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
2926 S HEADER CANAL
Permit Number:
Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA
A continuous air barrier shall be installed in the building envelope.
The exterior thermal envelope contains a continuous air barrier.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
The junction of the top plate and the top of exterior walls shall be sealed.
Knee walls shall be sealed.
The space between window/door jambs and framing, and
skylights and framing shall be sealed.
Rim joists shall include the air barrier.
The air barrier shall be installed at any exposed edge of insulation.
Exposed earth in unvented crawl spaces shall be covered with a
Class I vapor retarder with overlapping joints taped.
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Narrow cavities
Shafts, penetrations
Crawl space walls
Floors
(including
above-garage
and cantilevered floors)
Rim joists
Windows, skylights
Walls
Ceiling/attic
General
COMPONENT
Garage separation
Recessed lighting
Plumbing and wiring
S h o w e r / t u b
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
The air barrier shall be installed behind electrical or communication
boxes or air-sealed boxes shall be installed.
The air barrier installed at exterior walls adjacent to showers and
tubs shall separate them from the showers and tubs.
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Recessed light fixtures installed in the building thermal envelope shall
be sealed to the drywall.
Air sealing shall be provided between the garage and conditioned spaces.
When required to be sealed, concealed fire sprinklers shall only be sealed
in a manner that is recommended by the manuf acturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
C o n c e a l e d
Electrical/phone box on
exterior walls
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
INSULATION INSTALLATION CRITERIA
EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software7/15/2020 7:03 AM Page 1 of 1
Air-permeable insulation shall
not be used as a sealing material.
The insulation in any dropped ceiling/soffit
shall be aligned with the air barrier.
Cavities within corners and headers of frame walls
shall be insulated by completely filling the cavity with a
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Rim joists shall be insulated.
Floor framing cavity insulation shall be installed to
maintain permanent contact with the underside of
subfloor decking, or floor framing cavity insulation shall
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
and doors
on exterior wall
requirements
Recessed light fixtures installed in the building
thermal envelope shall be air tight and IC rated.
sprinklers
Where provided instead of floor insulation, insulation
shall be permanently attached to the crawlspace walls.
Exterior walls adjacent to showers and tubs shall be
insulated.
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Project Summary JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Project Information
DIEDERICH AND CHR ISTIE HUECKFor:
2926 S HEADER CANAL, FORT PIERCE, FL
Notes:
Design Information
Fort Pierce, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F42 Outside db °F90
Inside db °F70 Inside db °F75
Design TD °F28 Design TD °F15
Daily range M
Relative humidity %50
Moisture difference gr/lb61
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh27619 Struc ture Btuh24295
Ducts Btuh6180 Ducts Btuh2430
Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0
(none)(none)
Humidification Btuh0 Blower Btuh0
Piping Btuh0
Equipment load Btuh33799 Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load Btuh25389
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average
0Fireplaces Structure Btuh3202
Ducts Btuh2427
Central vent (0 cfm)Btuh0
CoolingHeating (none)
21262126Area (ft²)Equipment latent load Btuh5629
1977019770Volume (ft³)
Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh31018
Equiv. AVF (cfm)53105 Req. total capacity at 0.70 SHR ton3.0
Heating Equipment Summary Cooling Equipment Summary
Make Make Trane
Trade Trade TRANE
Model Cond 4TTR6036J1
AHRI ref Coil TEM4A0C37S31++TDR
AHRI ref 201763705
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input kW9.4 Sensible cooling Btuh24640
Heating output Btuh31958 Latent cooling Btuh10560
Temperature rise °F25 Total cooling Btuh35200
Actual air flow cfm1173 Actual air flow cfm1173
Air flow factor cfm/Btuh0.035 Air flow factor cfm/Btuh0.044
Static pressure in H2O1.00 Static pressure in H2O1.00
Space thermostat Load sensible heat ratio 0.83
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name Entire House M BATH
2 Exposed wall 186.0 ft 25.0 ft
3 Room height 9.3 ft 8.0 heat/coolft
4 Room dimensions ft15.0x10.0
5 Room area 2126.0 ft²150.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 176 176 705 385 120 120 480 263
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 630 476 1907 1042 80 74 294 161
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 7 2 191 249 7 2 191 249
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 20 1 588 859 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 17 1 492 726 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 80 4 2364 3487 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 30 2 882 1131 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 407 337 1349 737 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 25 25 735 551 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 20 20 591 443 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 25 25 735 498 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 360 283 1134 620 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 50 4 1470 2148 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 7 7 197 110 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 20 20 591 331 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 2126 2126 3371 2909 150 150 238 205
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 2126 186 7072 0 150 25 951 0
6 c) AED excursion 0 -57
Envelope loss/gain 24374 16226 2154 821
12 a) Infiltration 3245 869 413 111
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 7200 0
Subtotal (lines 6 to 13)27619 24295 2567 932
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 27619 24295 2567 932
15 Duct loads 22%10%6180 2430 22%10%574 93
Total room load 33799 26725 3141 1025
Air required (cfm)Air required (cfm)1173 1173 109 45
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 2
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name M WIC MASTER BEDROOM
2 Exposed wall 7.0 ft 21.0 ft
3 Room height 8.0 heat/coolft 9.0 heat/coolft
4 Room dimensions ft7.0x10.0 ft15.0x14.0
5 Room area 70.0 ft²210.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 56 56 224 123 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 126 106 424 232
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 20 1 588 859
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 63 43 172 94
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 20 20 591 443
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 70 70 111 96 210 210 333 287
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 70 7 266 0 210 21 799 0
6 c) AED excursion -14 -231
Envelope loss/gain 601 204 2907 1684
12 a) Infiltration 116 31 390 104
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 2000
Subtotal (lines 6 to 13)717 235 3296 3789
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 10 8
14 Subtotal 717 235 3306 3797
15 Duct loads 22%10%160 23 22%10%740 380
Total room load 877 258 4046 4177
Air required (cfm)Air required (cfm)30 11 140 183
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 3
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name UTILITY RM M HALL
2 Exposed wall 0 ft 0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft7.0x10.0 ft7.0x4.0
5 Room area 70.0 ft²28.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 70 70 111 96 28 28 44 38
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 70 0 0 0 28 0 0 0
6 c) AED excursion -34 -2
Envelope loss/gain 111 62 44 36
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 500 0
Subtotal (lines 6 to 13)111 562 44 36
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 17 14 -44 -36
14 Subtotal 128 576 0 0
15 Duct loads 22%10%29 58 22%36%0 0
Total room load 157 633 0 0
Air required (cfm)Air required (cfm)5 28 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 4
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name DINING KITCHEN
2 Exposed wall 22.0 ft 0 ft
3 Room height 8.0 heat/coolft 12.0 heat/coolft
4 Room dimensions ft9.0x13.0 ft22.0x13.0
5 Room area 117.0 ft²286.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 104 74 296 162 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 30 2 882 1131 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 72 47 188 103 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 25 25 735 498 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 117 117 186 160 286 286 453 391
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 117 22 837 0 286 0 0 0
6 c) AED excursion -123 -252
Envelope loss/gain 3124 1930 453 139
12 a) Infiltration 363 97 0 0
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 4000
Subtotal (lines 6 to 13)3487 2028 453 4139
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 2 2 15 12
14 Subtotal 3489 2030 468 4151
15 Duct loads 22%10%781 203 22%10%105 415
Total room load 4270 2233 573 4566
Air required (cfm)Air required (cfm)148 98 20 200
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 5
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name GREAT ROOM HALL
2 Exposed wall 16.0 ft 5.0 ft
3 Room height 12.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft22.0x16.0 ft5.0x5.0
5 Room area 352.0 ft²25.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 192 112 447 244 40 23 93 51
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 17 1 492 726
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 80 4 2364 3487 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 352 352 558 482 25 25 40 34
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 352 16 608 0 25 5 190 0
6 c) AED excursion -248 -48
Envelope loss/gain 3977 3965 815 764
12 a) Infiltration 396 106 83 22
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)4373 4071 898 786
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 299 262 -898 -786
14 Subtotal 4672 4333 0 0
15 Duct loads 22%10%1045 433 22%10%0 0
Total room load 5718 4766 0 0
Air required (cfm)Air required (cfm)198 209 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 6
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name BEDROOM 2 POWDER RM
2 Exposed wall 27.0 ft 0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft162.0x1.0 ft6.0x5.0
5 Room area 162.0 ft²30.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 88 88 352 193 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 128 103 412 225 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 25 25 735 551 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 162 162 257 222 30 30 48 41
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 162 27 1027 0 30 0 0 0
6 c) AED excursion -104 -2
Envelope loss/gain 2783 1087 48 39
12 a) Infiltration 446 119 0 0
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 500 0
Subtotal (lines 6 to 13)3229 1706 48 39
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 299 262 299 262
14 Subtotal 3528 1968 347 301
15 Duct loads 22%10%789 197 22%10%78 30
Total room load 4318 2165 424 331
Air required (cfm)Air required (cfm)150 95 15 15
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 7
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name SINK 1 BATH 2
2 Exposed wall 0 ft 0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft5.0x5.0 ft6.0x5.0
5 Room area 25.0 ft²30.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 25 25 40 34 30 30 48 41
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 25 0 0 0 30 0 0 0
6 c) AED excursion -2 -2
Envelope loss/gain 40 32 48 39
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)40 32 48 39
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 40 32 48 39
15 Duct loads 22%10%9 3 22%10%11 4
Total room load 49 35 58 43
Air required (cfm)Air required (cfm)2 2 2 2
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 8
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name SINK 2 WIC 2
2 Exposed wall 0 ft 6.0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft6.0x5.0 ft6.0x6.0
5 Room area 30.0 ft²36.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 48 48 192 105
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 30 30 48 41 36 36 57 49
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 30 0 0 0 36 6 228 0
6 c) AED excursion -2 -10
Envelope loss/gain 48 39 477 144
12 a) Infiltration 0 0 99 27
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)48 39 576 170
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 48 39 576 170
15 Duct loads 22%10%11 4 22%10%129 17
Total room load 58 43 705 187
Air required (cfm)Air required (cfm)2 2 24 8
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 9
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name WIC 3 BEDROOM 3
2 Exposed wall 14.0 ft 18.0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft7.0x7.0 ft12.0x13.0
5 Room area 49.0 ft²156.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 56 56 224 123 40 40 160 88
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 56 56 224 123 104 79 316 173
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 25 2 735 1074
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 49 49 78 67 156 156 247 213
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 49 14 532 0 156 18 684 0
6 c) AED excursion -21 331
Envelope loss/gain 1058 291 2143 1879
12 a) Infiltration 231 62 297 80
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)1289 352 2440 1959
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1289 352 2440 1959
15 Duct loads 22%10%289 35 22%10%546 196
Total room load 1578 388 2986 2155
Air required (cfm)Air required (cfm)55 17 104 95
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 10
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name FOYER DEN
2 Exposed wall 7.0 ft 11.0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft12.0x7.0 ft12.0x11.0
5 Room area 84.0 ft²132.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 56 29 117 64 88 63 252 138
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 25 2 735 1074
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 7 7 197 110 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 20 20 591 331 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 84 84 133 115 132 132 209 181
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 84 7 266 0 132 11 418 0
6 c) AED excursion 508 331
Envelope loss/gain 1304 1128 1615 1723
12 a) Infiltration 116 31 182 49
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 200
Subtotal (lines 6 to 13)1420 1159 1796 1972
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1420 1159 1796 1972
15 Duct loads 22%10%318 116 22%10%402 197
Total room load 1737 1275 2198 2169
Air required (cfm)Air required (cfm)60 56 76 95
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2020-Jul-15 06:41:02
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 11
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Right-J® Worksheet
JULY 15, 2020Date:Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
1 Room name PANTRY DEN WIC
2 Exposed wall 0 ft 7.0 ft
3 Room height 8.0 heat/coolft 8.0 heat/coolft
4 Room dimensions ft7.0x7.0 ft5.0x7.0
5 Room area 49.0 ft²35.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 38.3438.34 0 0 0 0 0 0 0 0
.GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
11 GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 43.3743.37 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ee 29.4029.40 37.7237.72 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 22.0422.04 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ss 29.4029.40 19.9019.90 0 0 0 0 0 0 0 0
WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 56 56 224 123
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 42.9542.95 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
GG 2 glazing, clr low-e 1.0502 glazing, clr low-e 1.050 ww 29.4029.40 16.4716.47 0 0 0 0 0 0 0 0
CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 49 49 78 67 35 35 55 48
FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 49 0 0 0 35 7 266 0
6 c) AED excursion -4 -12
Envelope loss/gain 78 63 546 159
12 a) Infiltration 0 0 116 31
b) Room ventilation 0 0 0 0
13 Internal gains:Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)78 63 661 190
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 78 63 661 190
15 Duct loads 22%10%17 6 22%10%148 19
Total room load 95 70 809 209
Air required (cfm)Air required (cfm)3 3 28 9
2020-Jul-15 06:41:09
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 1
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Job:Duct System Summary JULY 15, 2020Date:
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Project Information
DIEDERICH AND CHR ISTIE HUECKFor:
2926 S HEADER CANAL, FORT PIERCE, FL
CoolingHeating
External static pressure in H2O1.00in H2O1.00
Pressure losses in H2O0in H2O0
Available static pressure in H2O1.00in H2O1.00
Supply / return available pressure 0.500 / 0.500 in H2O in H2O0.500 / 0.500
Lowest friction rate in/100ft1.000in/100ft1.000
Actual air flow cfm1173cfm1173
Total effective length (TEL)ft251
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk
st4135.047.4VlFx0x04.01.0002258hBATH 2
st5155.059.3VlFx0x07.01.000951504318hBEDROOM 2
st4135.045.7VlFx0x07.01.000951042986hBEDROOM 3
st3115.026.2VlFx0x07.01.00095762169cDEN
st3115.029.5VlFx0x04.01.000928809hDEN WIC
st2115.014.2VlFx0x07.01.000981484270hDINING
st4135.047.0VlFx0x06.01.00056601737hFOYER
st4135.043.9VlFx0x07.01.000105992383cGREAT ROOM
st6175.075.7VlFx0x07.01.000105992383cGREAT ROOM-A
st2115.020.7VlFx0x07.01.000100102283cKITCHEN
st3115.026.3VlFx0x07.01.000100102283cKITCHEN-A
st1115.017.2VlFx0x06.01.000451093141hM BATH
st1115.016.8VlFx0x04.01.0001130877hM WIC
st1115.022.6VlFx0x07.01.00092702088cMASTER BEDROOM
st1115.014.2VlFx0x07.01.00092702088cMASTER BEDROOM-A
st3115.024.0VlFx0x04.01.0003395hPANTRY
st6175.070.4VlFx0x04.01.0001515424hPOWDER RM
st6175.072.6VlFx0x04.01.0002249hSINK 1
st5155.055.5VlFx0x04.01.0002258hSINK 2
st2115.020.0VlFx0x05.01.000285633cUTILITY RM
st5155.055.5VlFx0x04.01.000824705hWIC 2
st5155.055.3VlFx0x04.01.00017551578hWIC 3
2020-Jul-15 06:41:09
Right-Suite® Universal 2019 19.0.08 RSU08101 Page 2
E:\Documnets\Wrightsoft HVAC\HUECK RESIDENCE.rup Calc = MJ8 Front Door faces: W
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
st6 Peak AVF 116 121 1.000 451 7.0 0x0 VinlFlx st5
st5 Peak AVF 347 243 1.000 785 9.0 0x0 VinlFlx st4
st4 Peak AVF 612 500 1.000 779 12.0 0x0 VinlFlx st3
st3 Peak AVF 730 707 1.000 682 14.0 0x0 VinlFlx
st2 Peak AVF 164 226 1.000 512 9.0 0x0 VinlFlx
st1 Peak AVF 280 240 1.000 634 9.0 0x0 VinlFlx
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk
rb1 0x 11730 1173 0 0 0 0 x0 0 VlFx
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 77/15/2020 7:02 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
DIEDERICH AND CHRISTIE HUECK
HUECK RESIDENCE
Street:
City, State, Zip: FORT PIERCE , FL ,
2926 S HEADER CANAL
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Single-family
1
No
2126
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=1.06 173.33 ft²
SHGC=0.25
Sgl, U=1.11 80.00 ft²
SHGC=0.23
Sgl, U=1.05 40.00 ft²
SHGC=0.22
other (see details)6.67 ft²
other (see details)
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 2126.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1573.00 ft²
b. Frame - Wood, Adjacent R=13.0 492.00 ft²
c. N/A R=f t ²
10. Ceiling Types
a. Roof Deck (Unvented)R=20.0 2126.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:12.578 ft.
Area Weighted Average SHGC:0.241
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
3
(300.0 sqft.)
(2065.0 sqft.)
(2126.0 sqft.)
(2126.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
35.2 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 150
EF: 0.980
Glass/Floor Area: 0.141
Total Proposed Modified Loads:
Total Baseline Loads:
64.23
68.87 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
7-15-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
DIEDERICH AND CHRISTIE
HUECK RESIDENCE
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
2126
3
New (From Plans)
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FORT PIERCE ,
St. Lucie
2926 S HEADER CANA
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 2126 19770
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 M BATH 150 1200 No 0 Yes Yes1 Yes
2 M WIC 70 560 No 0 Yes Yes1 Yes
3 MASTER BEDROO 210 1890 No 0 1 Yes Yes1 Yes
4 UTILITY RM 70 560 No 0 Yes Yes1 No
5 M HALL 28 224 No 0 Yes Yes1 No
6 DINING 117 936 No 0 Yes Yes1 Yes
7 KITCHEN 286 3432 Yes 0 Yes Yes1 No
8 GREAT ROOM 352 4224 No 0 Yes Yes1 Yes
9 HALL 25 200 No 0 Yes Yes1 Yes
10 BEDROOM 2 162 1296 No 0 1 Yes Yes1 Yes
11 POWDER RM 30 240 No 0 Yes Yes1 No
12 SINK 1 25 200 No 0 Yes Yes1 No
13 BATH 2 30 240 No 0 Yes Yes1 No
14 SINK 2 30 240 No 0 Yes Yes1 No
15 WIC 2 36 288 No 0 Yes Yes1 Yes
16 WIC 3 49 392 No 0 Yes Yes1 Yes
17 BEDROOM 3 156 1248 No 0 1 Yes Yes1 Yes
18 FOYER 84 672 No 0 Yes Yes1 Yes
19 DEN 132 1056 No 0 Yes Yes1 Yes
20 PANTRY 49 392 No 0 Yes Yes1 No
21 DEN WIC 35 280 No 0 Yes Yes1 Yes
7/15/2020 7:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 150 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft M BATH
2 70 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft M WIC
3 210 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -021 ft MASTER BEDRO
4 70 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft UTILITY RM
5 28 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M HALL
6 117 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -022 ft DINING
7 286 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft KITCHEN
8 352 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -016 ft GREAT ROOM
9 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft HALL
10 162 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -027 ft BEDROOM 2
11 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft POWDER RM
12 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft SINK 1
13 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft BATH 2
14 30 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft SINK 2
15 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft WIC 2
16 49 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft WIC 3
17 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -018 ft BEDROOM 3
18 84 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft FOYER
19 132 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft DEN
20 49 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY
21 35 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft DEN WIC
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Metal 2378 ft² Light 0.1 20 26.6______No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 2126 ft² N N0
7/15/2020 7:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented)0 150 ft² 0.1 Wood______M BATH Blown
2 Under Attic (Unvented)0 70 ft² 0.1 Wood______M WIC Blown
3 Under Attic (Unvented)0 210 ft² 0.1 Wood______MASTER BEDRO Blown
4 Under Attic (Unvented)0 70 ft² 0.1 Wood______UTILITY RM Blown
5 Under Attic (Unvented)0 28 ft² 0.1 Wood______M HALL Blown
6 Under Attic (Unvented)0 117 ft² 0.1 Wood______DINING Blown
7 Under Attic (Unvented)0 286 ft² 0.1 Wood______KITCHEN Blown
8 Under Attic (Unvented)0 352 ft² 0.1 Wood______GREAT ROOM Blown
9 Under Attic (Unvented)0 25 ft² 0.1 Wood______HALL Blown
10 Under Attic (Unvented)0 162 ft² 0.1 Wood______BEDROOM 2 Blown
11 Under Attic (Unvented)0 30 ft² 0.1 Wood______POWDER RM Blown
12 Under Attic (Unvented)0 25 ft² 0.1 Wood______SINK 1 Blown
13 Under Attic (Unvented)0 30 ft² 0.1 Wood______BATH 2 Blown
14 Under Attic (Unvented)0 30 ft² 0.1 Wood______SINK 2 Blown
15 Under Attic (Unvented)0 36 ft² 0.1 Wood______WIC 2 Blown
16 Under Attic (Unvented)0 49 ft² 0.1 Wood______WIC 3 Blown
17 Under Attic (Unvented)0 156 ft² 0.1 Wood______BEDROOM 3 Blown
18 Under Attic (Unvented)0 84 ft² 0.1 Wood______FOYER Blown
19 Under Attic (Unvented)0 132 ft² 0.1 Wood______DEN Blown
20 Under Attic (Unvented)0 49 ft² 0.1 Wood______PANTRY Blown
21 Under Attic (Unvented)0 35 ft² 0.1 Wood______DEN WIC Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0M BATH 00015 8N Concrete Block - Int Insul 0.10Exterior120.0 ft² ____
2 4.1 0M BATH 00010 8E Concrete Block - Int Insul 0.10Exterior80.0 ft² ____
3 4.1 0M WIC 0007 8N Concrete Block - Int Insul 0.10Exterior56.0 ft² ____
4 13 0M WIC 00010 8W Frame - Wood 0.10.1Garage80.0 ft² ____
5 4.1 0MASTER BE 00014 9E Concrete Block - Int Insul 0.10Exterior126.0 ft² ____
6 4.1 0MASTER BE 0007 9S Concrete Block - Int Insul 0.10Exterior63.0 ft² ____
7 13 0UTILITY RM 00010 8W Frame - Wood 0.10.1Garage80.0 ft² ____
8 13 0M HALL 0004 8W Frame - Wood 0.10.1Garage32.0 ft² ____
9 4.1 0DINING00013 8E Concrete Block - Int Insul 0.10Exterior104.0 ft² ____
10 4.1 0DINING0009 8S Concrete Block - Int Insul 0.10Exterior72.0 ft² ____
11 13 0KITCHEN00017 12N Frame - Wood 0.10.1Garage204.0 ft² ____
12 4.1 0GREAT ROO 00016 12E Concrete Block - Int Insul 0.10Exterior192.0 ft² ____
13 4.1 0HALL0005 8E Concrete Block - Int Insul 0.10Exterior40.0 ft² ____
14 4.1 0BEDROOM 2 00011 8E Concrete Block - Int Insul 0.10Exterior88.0 ft² ____
15 4.1 0BEDROOM 2 00016 8S Concrete Block - Int Insul 0.10Exterior128.0 ft² ____
16 4.1 0WIC 2 0006 8S Concrete Block - Int Insul 0.10Exterior48.0 ft² ____
17 4.1 0WIC 3 0007 8S Concrete Block - Int Insul 0.10Exterior56.0 ft² ____
18 4.1 0WIC 3 0007 8W Concrete Block - Int Insul 0.10Exterior56.0 ft² ____
19 4.1 0BEDROOM 3 0005 8S Concrete Block - Int Insul 0.10Exterior40.0 ft² ____
7/15/2020 7:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
20 4.1 0BEDROOM 3 00013 8W Concrete Block - Int Insul 0.10Exterior104.0 ft² ____
21 4.1 0FOYER0007 8W Concrete Block - Int Insul 0.10Exterior56.0 ft² ____
22 4.1 0DEN00011 8W Concrete Block - Int Insul 0.10Exterior88.0 ft² ____
23 13 0PANTRY0007 8N Frame - Wood 0.10.1Garage56.0 ft² ____
24 4.1 0DEN WIC 0007 8W Concrete Block - Int Insul 0.10Exterior56.0 ft² ____
25 13 0DEN WIC 0005 8N Frame - Wood 0.10.1Garage40.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 E Low-E Single 0.99 0.27 6.7 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes2 Y
2 E Low-E Single 1.05 0.22 20.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes5 Y
3 S Low-E Single 1.05 0.22 20.0 ft² 10 ft 0 in 1 ft 4 in NoneMetal None______Yes6 Y
4 E Low-E Single 1.06 0.25 30.0 ft² 12 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes9 Y
5 S Low-E Single 1.06 0.25 25.0 ft² 18 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes10 Y
6 E Low-E Single 1.11 0.23 80.0 ft² 18 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y
7 E Low-E Single 1.06 0.25 16.7 ft² 18 ft 0 in 1 ft 4 in NoneMetal None______Yes13 Y
8 S Low-E Single 1.06 0.25 25.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes15 Y
9 W Low-E Single 1.06 0.25 25.0 ft² 12 ft 0 in 1 ft 4 in NoneMetal None______Yes20 Y
10 W Low-E Single 1.06 0.25 6.7 ft² 12 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes21 Y
11 W Low-E Single 1.06 0.25 20.0 ft² 12 ft 0 in 1 f t 4 in Drapes/blindsMetal Exterior 5______Yes21 Y
12 W Low-E Single 1.06 0.25 25.0 ft² 12 ft 0 in 1 f t 4 in NoneMetal None______Yes22 Y
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 816 ft² 816 ft² 53 ft 8 ft 13______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1647.5 590.45.000295Wholehouse .1087170.1Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1
7/15/2020 7:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/SEER: 16 35.2 kBtu/hr 1056 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 150 ft² Attic 15 ft² Prop. Leak Free Garage 63.8 cfm 0.03 0.50______1 1 --- cfm
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 DINING
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 LAUNDRY
Default(8 lbs/sq.ft.f t ² f t 0.3 HALLWAY
Default(8 lbs/sq.ft.f t ² f t 0.3 POWDER RM
Default(8 lbs/sq.ft.f t ² f t 0.3 STORAGE WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 PANTRY
Default(8 lbs/sq.ft.f t ² f t 0.3 OFFICE
Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER
Default(8 lbs/sq.ft.f t ² f t 0.3 GREAT ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER SUITE
Default(8 lbs/sq.ft.f t ² f t 0.3 STORAGE
7/15/2020 7:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC
Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 SITTING
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2B
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2A
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3B
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3A
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 4
Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 4
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2
Default(8 lbs/sq.ft.f t ² f t 0.3 WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 STAIR UP
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 LOFT
7/15/2020 7:02 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. __________ New (From Plans)
2. Single-family or multiple-family 2. __________ Single-family
3. No. of units (if multiple-family)3. __________ 1
4. Number of bedrooms 4. __________ 3
5. Is this a worst case? (yes/no)5. __________No
6. Conditioned floor area (sq. ft.)6. __________2126
7. Windows, type and area
a) U-factor:(weighted average) 7a._________1.070
b) Solar Heat Gain Coefficient (SHGC) 7b._________0.241
c) Area 7c._________300.0
8. Skylights
a) U-factor:(weighted average) 8a._________NA
b) Solar Heat Gain Coefficient (SHGC) 8b._________NA
9. Floor type, insulation level:
a) Slab-on-grade (R-value) 9a._________0.0
b) Wood, raised (R-value) 9b._________
c) Concrete, raised (R-value) 9c._________
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value) 10A1.________
2. Masonry (Insulation R-value) 10A2.________4.1
B. Adjacent:
1. Wood frame (Insulation R-value) 10B1.________13.0
2. Masonry (Insulation R-value) 10B2.________
11. Ceiling type and insulation level
a) Under attic 11a.________0.0
b) Single assembly 11b.________
c) Knee walls/skylight walls 11c.________
d) Radiant barrier installed 11d.________No
12. Ducts, location & insulation level
a) Supply ducts R_______6.0
b) Return ducts R_______6.0
c) AHU location Garage
13. Cooling system: Capacity_______35.2
a) Split system SEER_______16.0
b) Single package SEER_______
c) Ground/water source SEER/COP_______
d) Room unit/PTAC EER_______
e) Other __________
14. Heating system:Capacity_______27.0
a) Split system heat pump HSPF_______
b) Single package heat pump HSPF_______
c) Electric resistance COP_______1.0
d) Gas furnace, natural gas AFUE_______
e) Gas furnace, LPG AFUE_______
f) Other
15. Water heating system
a) Electric resistance EF_______0.98
b) Gas fired, natural gas EF_______
c) Gas fired, LPG EF_______
d) Solar system with tank EF_______
e) Dedicated heat pump with tank EF_____
f) Heat recovery unit HeatRec%_______
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans _________
b) Cross ventilation _________No
c) Whole house fan _________No
d) Multizone cooling credit _________
e) Multizone heating credit _________
f) Programmable thermostat _________No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:_________________________________________Date:____________________________________
Address of New Home: ____________________________________City/FL Zip: ________________________________2926 S HEADER CANAL FORT PIERCE, FL
7/15/2020 7:03:19 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������