HomeMy WebLinkAboutBathroom LocationsProvide Simpson LSTA18 at each
stud to top plate to exi'sti'ng beam connection
xisyng beam /to "Mal
6" Studs
anchor ' bolts
��-�-loll
I
I
I
I
IIII
IIII
� '' IIII
each stud to bottom
I
I
II
IN
II
DETAIL
Grout sill solid
Drywall at
ceilings shall be
leveled and attached to bottom chord
I
I
I
IIII
6" Studs
anchor ' bolts
with min.
T' embedment
at 32" o.c.' w/ Simpson
SP6 at
each stud to bottom
plate connection
FRAME
IN
WALL
DETAIL
Strap new studs to exis
plate using Simpson 1-12.=
Strap at each stud to I
2" x 6" studs with
R-19 baits insulation
between each
2 x 8
w/ f ramin on e
dge
Simpson L%T 12,4
ting
�l
to verif ALL
notes and dimensions prior to proceeding with work 2"x4" Wood Buck
)late
u
O) Q
�
U
3.
No dissimilar
metals to touch.
T l Si -Fold D D t l
Grout sill solid
Drywall at
ceilings shall be
leveled and attached to bottom chord
as needed for
p i e a
oor e a I
Perpendicular
window attachment
with screws per
FBC 8102.3.5.
S.
I �
in contact with
concrete shall be pressure treated. NTS
Existing
e walvxto remain
4011h x 47w x 28" h
NEW WINDOW IN EXISTING
OPENING DETAIL
Scale: 1/2" = 1'-0"
NTS
Dowel #4 x 12" long bar
(.x(. — 10/10 WWM 6" into existing slab and
OR FIBER—MIX over cold ,joint set in epoxy at 48" o.c.
vapor barrier
12"
6„ Existing slab
4 4'
6 mil vapor L
barrier
Existing Floor F'lan
SCALE 114" = I' -O"
-6„
BATH
i floor Plan w/ Electric
New plumbing pipe Well compacted fill
or electrical conduit etc... with termite treatment
Slab R Detail
move existing window header
1/8" thick 11gght textured stucco
on plastic IatF� over house wrap on
�Iq/32" CDX plywood nailed 6" o.c. In
field and on edges w/ IOd ring shank
nails. Color t Texture to Match Existing
IWA
SHOWER
SCALE 1/4" = 1'-0"
WALL SYMBOL LEGEND
TYPICAL NOTES:
Remove Wall
For NEW Door
l�
y
��o
\ IIS
j z \
W
�+AI c
>) o0
+ \
i
Remove EXISTING
Door
Remove EXISTING
FIXTURES
Demolition Plan
= EXISTING Walls
= 2" x 4" NEW non-bearing stud walls - see sections.
Insulate with R-11 batts at bathrooms t between
A/C and Non -A/C spaces
------i
I
I
I
I
SCALE 1/4" = 1'-0"
wallboard
casing
'2"x4" Wood Buck
Note:
all doors
to be prehung
Tgpical Interior Door Detail
gypsum wallboard
reinforce corner
metal top track
bi-fold dot
C
U
�l
to verif ALL
notes and dimensions prior to proceeding with work 2"x4" Wood Buck
Na
4JL z
u
O) Q
�
U
NTS
2"x4" Wood Buck I V
dote-
io track 9 bottom
>f door, use fir.
)racket a pivot
wood Casing
Ipsum wallboard
reinforce corners
,bi-fold door
1.
Contractor
to verif ALL
notes and dimensions prior to proceeding with work 2"x4" Wood Buck
2.
Contractor
to STRICTLY
enforce ALL OSHA Requirements. Jamb
3.
No dissimilar
metals to touch.
T l Si -Fold D D t l
4.
Drywall at
ceilings shall be
leveled and attached to bottom chord
g
p i e a
oor e a I
Perpendicular
of trusses
with screws per
FBC 8102.3.5.
S.
ALL wood
in contact with
concrete shall be pressure treated. NTS
6
ALL IId
I d f hd 11 d
wa imensions are nomina an not finis a wa or stu imensions.
1. ALL plumbing fixtures to be low flow.
8. Wall and Celling shall have a flame -spread classification of not greater than
200 per FBC R302.9.1
9. Wall and telling finishes shall have a smoke -developed Index of not greater
than -450 per FBC R302_9-2
10. Gypsum board material shall conform to ASTM C36, C19, C-{15, C514, C630, C931
C960, C1002, C1041,C1111, C1118, C1218, C1395, or C1396 and shall be Installed
according to the following: (FBC 8102.3.5) See table below for attachment
ll. ALL ceramic tele surfaces Installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
12. Cement, fiber -cement or glass mat gypsum backers In accordance with ASTM
C1288, C1325, OR C1118 and Installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tele in tub areas and wall panels In shower areas.
13. Insulation Including facings such as retarders or vapor permeable members Installed
within floor -telling assemblies, roof -telling assemblies, wall, crawl spaces and attics
shall have a flame spread Index not to exceed 25 with an accompan,yin smoke
developed Index not to exceed 450 when tested in accordance with ASTM E 8-{.
Insulation shall comply with F.B.C. 8316.
Drywall Attachment Table FBC 8102.3.5
Drgwall Locatio
Ceiling
y2
Walls
Ceiling
s"
Walls
Thickness Orientation
Framing
Member
Max. spacing
Nail sizing o tions for
p
Spacing
of fasteners
installation of drywall into
MaximumNails
Screws
wood framing members
2" x min. thickness
Perpendicular
24"
.7"
12"
13ga 1 3/8" long with 19/64" head
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
OR
0.080" dia. x 1 5/8" long with
Either
Ib"
8"
141,
Direction
15/64" head
OR
G board nail 0.086" dia.
1psum
x 5/8" with 9/32" head.
Perpendicular
24"
i"
12"
13ga 1 5/8" long with 19/64" head
0.098" diameter x 13/8" long
annular -ringed or dd cooler nail
OR
0.092" dia. xx 1 1/8" long with
Either
16"
8"
141,
Direction
1/4" head
OR
G1psum board nail 0.0915" dia.
x 1/8" with 19/64" head.
b
N
X
W
5/8" drywall ceiling on
2 x 4 top plate truss bottom cord
1/2" drgwall on
2" x 4 studs at 16" o.c
Finish to match existing
New base—board
to match existingprofile
2" x 4" P.T. bottom plate
Electrical Symbol Le end
$ Single Pole Switch
Duplex Outlet
Exhaust Fan
® Recessed Can Light
�C�Wall Mounted Light
ELECTRIC NOTES: '
14. Use copper wire only, no aluminum.
15. Contractor to verify location of electrical service and provider
16. All NEW recessed cans to be installed per NFPA requirements.
11. All NEW branch circuits that supply 125v single phase 15 amp or 20 amp outlets
shall be protected bg combination -type AFCI Circuit Breakers.
18. ALL new receptacles to be Tamper resistant AFCI.
19. Electrician to complete electrical load calculation and panel schedules as
required bg the governing building department.
existing slab-'
Interior Non—Bearing Partition
Scale: 1/2" = 1'-O"
D oor Schedule
Mark Size Door Description
A 2'-4" X 6'-8" Solid Core - Wood
B I'-6" X 6'-6" I BI -Fold
verify all masonry/rough opening
sizes prior to ordering windows.
Digitally signed
by Daniel Braden
Date: 2020.07.24
11:00:54 -04'00'
L
O �
LL
V
N
Q
Q�
N
�- QC 111 o O
UJ =3 U O
Z W Ln M " O
< >N N U
<< <
��� <
I Z NN03
#
Cr
Q Ci
aj U U -- �- � b-
_ Cq
U_ .- 1L
X
A�
Q3
SHEET NO:
OF I.
JOB NUMBER:
20-101
IfM
,OA�EL R. Q � off' V
®®
AR 9770 o �
ON
J
J
N
to