Loading...
HomeMy WebLinkAboutProduct Approval; Roof Tiles Adhesives1041612019 Florida Building Code Online bT �`jLfi BCIS Home i Log In User Registration I Hot Topics Submit Surcharge j Stats & Facts j Publications I Contact Us ecis Site Map Unks •Search dbryProduct Approval ty+:U5E0.; Public User n �r Product Uproval Menu > Product or Application Search > Application List > Application Detail ",' I'. FL # FL6332-RS 19 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer ICP Adhesives & Sealants, Inc. Address/Phone/Email 12505 NW 44th Street Coral Springs, FL 33065 (888) 774-1419 Ext 201 rylipelkonen@icpadhesives.com Authorized Signature R1ku Yllpelkonen rylipelkonen@icpadhesives.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roof Tile Adhesives Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/07/2021 Validated By John W. Knezevich, PE I Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL6332 R8 COI 2017 01 COI Nleminen.odf Standard SSTD 11 Year 1997 Product Approval Method Method 1 Option D https://www.floridabuilding.org/pr/pr app_dg.aspx?param=wGEVXQwtDquanCtKft6fp/p2fMp/p2b3ax6XpXuocQWKcLM2jp/o2bQp/P3d 1/2 10/16/2019 Florida Building Code Online Date Submitted 10/12/2017 Date Validated 10/14/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 FL#-----------� Model, Number or Name Description 6332.1 ICP Adhesives Polyset AH-160 Dual component expanding polyurethane roof tile adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL6332 R8 If 2017 10 FINAL ER rCP AH160 FL6332- )t_-adf Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +n/a/-178 Verified By: Robert Nleminen PE-59166 Created by Independent Third Party: Yes !i Other: 1.) The design pressure limitation in this application Evaluation Reports refers to hip and ridge tiles in one configuration. Refer to Table 2 of ER for all hip and ridge the limitations. 2.) Field tiles are FL6332 R8 AE 2017 SO FINAL ER ICP AHS60 FL6332- R8.odf designed based on overturning moment resistance. Refer to Created by Independent Third Party: Yes Table 1 of ER for field tile limitations. 3.) Refer to ER Sections S for other Limitations of Use. " Buck Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA1EE0 employer. jropylj9ht 2007-2013 State of Florida.:: Privacy Statement:: AccesslbIlty Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please mmad 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an emall address which can be made avallable to the public. To determine if you are a licensee under Chapter 455, F.S., please dI& hem . Product App�Cro�a.vr�al Accepts: gZ,Fsti a 6eCtIT11:} AIFTRICSr� https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQw(DquanCtKfl6fa/o2fM%2b3ax6XpXuocQWKcLM2j%2bQ°/3d 212 ! ! KINITY ERD EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization A9503 353 CHRISTIAN STREET, UNIT 13 OXFORD, CT 06478 (203)262-9245 EVALUATION REPORT ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-RS 12505 NW 44t1i Street FL6332-R8 Coral Springs, FL 33065 (888)774-1419 Date of Issuance:08/08/2008 Revision 8: 10/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2027) Florida Building Code sections noted herein. DESCRIPTION: ICP Adhesives Polyset° AH-160 LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number, preceded by the words "'Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/12/2017. This does notserye as an elecmonlwlly signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, U.C. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, I.I.C. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �INITY i ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roof Tile Adhesives Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has demonstrated compliance with the 6th Edition (2017) Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Sections Property Standard Year 1504.2.1.1 Overturning resistance SSTD 11 1997 3. REFERENCES: 9MR11 Examination Reference Date ERD (TST 6049) Static Uplift —5STD 11 P39740.02.12 02/20/2012 ERD (rST 6049) Static Uplift—SSTD 11 P39740.11.13-R1 01/02/2015 [CC-ES(EVL2396) 20121BC Compliance ESR-1709 12/01/2016 Miami -Dade (CER 1592) HVHZ compliance 17-0322.03 04/27/2017 PRI (TST 5878) Static Uplift—SSTD 11 ECM-001-02-01 09/21/2001 PRI (TST 5878) Static Uplift—SSTD 11 PFI-006-02-01 05/09/2005 PRI (TST 5878) Static Uplift —SSTD 11 PFI-006-02-02 05/09/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFI-007-02-01 10/11/2005 PRI (TST 5878) Static Uplift—SSTD 11 PFI-008-02-04 02/21/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFI-009-02-03 02/21/2006 PRI (TST 5878) Static Uplift —SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 TGRI-001-02-03 10/30/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-010-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-011-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-012-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-013-02-01 12/07/2006 PRI (TST 5878) Static Uplift—SSTD 11 PFPI-014-02-01 12/07/2006 PRI (TST 5878) Static Uplift— SSTD 11 ECM-003-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-004-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-005-02-01 06/13/2008 FRI(TST 5878) Static Uplift —SSTD 11 ECM-006-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-007-02-01 06/13/2008 PRI (TST 5878) Static Uplift—SSTD 11 ECM-008-02-01 06/13/2008 UL LLC(QUA 9625) Quality Assurance Service Confirmation Exp.06/05/2018 4. PRODUCT DESCRIPTION: 4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are available in refillable tanks or disposable cylinders (ICP Adhesives PrOPacks 30 & 100). S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 Certtilmte of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset° AH-160: (888) 774-1419 Revision 8: 10/12/2017 Page 2 of 9 `J TRINITY ( ERD I 5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this product and FBC 1505.2. 5.4 ICP Adhesives Polyset® AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction. 5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives Polyset® AH-160. 5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to projects having an Aerodynamic Uplift Moment (M,), determined in accordance with FBC 1609.5.3 or Tables 2A and 2B of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. t`�1-'��q�t '"t � `'` �TABLBI TFIELD TILES IN ICP3ADHEs�GES PO �sET�AH�l(�'i0 s s .���x�''rl v � �;�,J a� y � ; � -� , � � `- `to- r� ALLO ABLE0IVERTURNING M01)1��JTpPERPbRMANCE DATAy �'e tt F s, <� : F. L ki"�`.`f.,�s �'2To1 tARGINOFSA FfyfLgf<?ADY PQUED FOAI OEOENDfNft51NGL[sOs,,P�SaNflNNOUS PAODY�PLACEnMEFIr-ifpq' ''aai a`�'����.��'n..�:L�:ti�(,•kk�'4�r01`,MARGINOFSAfEryALRL1DYAYYL EO`FINiERDEaENOEMfTwo'PAOOVJ�P(AfEMENr„i��'�i'��t�'�i�a', ,«" �`4s�k!}T? Tile (FBC 1609.5.3) Adhesive Paddy Placement Allowable overturning Type Profile Moment (ft-lbfl Independent, Single Paddy, Medium (2x7-inch,-30 gram) 60 Clay or Flat Independent; Single Paddy, Large (2x10-inch, -45 gram) 112 Concrete Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at tile overlap) 54 Independent; Single Paddy, Medium (W-inch, -30 gram) - 39 Clay or Low/ Independent; Single Paddy, Large (2x10-inch, -54 gram) 67 Concrete Medium Interdependent; Two Paddy (44-inch on underlayment, 2x4-Inch at tile overlap) 58 • Clay High Independent; Single Paddy, Large (WO -Inch, -45 gram) 134 Independent; Single Paddy, Medium (20-inch, -30 gram) 65 Clay or High Independent; Single Paddy, Large (2x10-inch, -63 gram) 109 Concrete Interdependent; Two Paddy (44-Inch an underlayment, 2x4-Inch attile overlap) 40 Clay Barrel 2x10-inch x `35 gram for pans; 2 @ WO -inch x-17 gram for cap 147 Concrete Barrel 240-Inch x -35 gram for pans; 2 @ WO -inch x-17 gram for cap 107 Clay Cap atop 2x Independent: Continuous Paddy ('"34 gram/ft) 135 stringer Concrete Cap atop 2x Independent: Continuous Paddy 1-34 gram/ft) 116 stringer ClayCap atop 2x Interdependent: 105 stringer Head: One (1) #10 x 2Y," screw; Overlap: 1 x 6 inch (" 10.5 gram) Concrete Cap atop 2x Interdependent: 76 stringer Head: One (1) #10 x 2Y," screw; Overlap: 1 x 6 inch (^10.5 gram) 5.6.1 Data in Table 1 relates to installation over a'30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP Adhesives Polyseta AH-160. 5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'. Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 Cert/Pcote of Authorfrodon#9503 6" EDITION (2027) FBC NON-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyset• AH-160, (8881774-1419 Revision 8:10/12/2017 Page 3 of 9 `JI RINITY ERD 5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details. HIP&t'RIDGEATILES IN 4CP ADTIESIV,�S�T POLYS s tax F4L '�Nb a Fit a't�t. `.i� t 31vv1 S/Yr* i iNrhi'd gy t�,� h��r�:r A40WA0).�UPLIfd RE5�f5TaANCEPERFO,RMI�NCHPAT�A E 4�1���,� ?y �w ns r-groy .fit' � ��v� ��tzir <e-,,,n � �i � ,,�_. a'`�u.F �' '83f� Yf5 `�� jC 2rr01 MARGINOFSAFE7ydLREAOYAPPl?IEa LqR INDEPENDEN(fCONrINUOUS P�100Y�P610EMENT§ d PtactrotEryt?; U��".l�xf ti,� .r�a� „t,,,Q To3 MARGINOfj$QFErALR!'AOYAPPLIEa wRINiEROEPEISDENT ,.-s ..,+�x=� au..w� v:� Allowable Tile Substrate Attachment Method Design Pressure (Psf) Clay 2x PT ridge board Independent: Continuous Paddy (-34 gram/ft) 116 Concrete 2x PT ridge board Independent: Continuous Paddy (- 34 gram/ft) 107 Interdependent: Head: One (1) R10 x 2%" screw; Clay 2x PT ridge board Overlap: 1 x 6 inch (-10.5 gram) 90 Interdependent: Head: One (1) k10 x 2%" screw; Concrete 2x PT ridge board Overlap: 1 x 6 inch (-10.5 gram) 56 Clayor Hip & Ridge Channel Metal (FL5374): Independent: Continuous Paddy (-34 gram/ft) 169 Concrete galvanized only Clay or Trim Lock" (FL5374): aluminum, Independent: Continuous Paddy ('"34 gram/k) 173 Concrete galvanized, Galvalumee orstainless steel Clay or Trim Lock`" Plus (FL537® ): aluminum, Independent: Continuous Paddy (' 34 gram/ft) 178 Concrete galvanized, Galvolume or stainless steel Clay Top Notch (FL8095) Independent: Continuous Paddy (' 32 gram/ft) 125 Concrete :Top Notch (FL8095) I Independent: Continuous Paddy (^' 32 gram/ft) 146 6. INSTALLATION: 6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the limitations outlined in Section 5. 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval. 6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP Adhesives and Sealants, Inc. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Tomball, TX 9. QUALITY ASSURANCE ENTITY: UL, LLC. - QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8 rerafcate afAut&,heaon H903 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL633Z-Rg ICP Adhesives Polyset° AH-160, (888) 774-1429 Revision 8: 10/22/2017 Page 4 of 9 `J TRIM ERD 10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE): - 10.1 Independent, Medium Paddy: Nail through plastic cement Paddy (Beneath Tile) (when required) Underayment ° Er Battens optional ti Eave Course oa a� 1Om �. Fasda Gave Closure \ Flat/Low Profile Tile Exterior Research and Design, I.I.C. Certi lmte ofAutharhation #9503 Nall through plastic cement (when required) Paddy (Beneath Tile) Underlayment --:, ` 71n\�31n. Battens optional "ti... 10in. 21n. Eave Closure Gave Course Fascia Medium ProffleTile Nail through plastic ce (when requlred) /Paddy(Beneath Tile) Underlayment Y 7�2 Battens optionalnal r Zda r X Eave Course Fascia Weephole loin. tin. Gave closure Drip edge High Profile Tile bra EDITION (2017) FBC NON-HVHZ EVALUATION ICP Adhesives Polyseta AH-360, (888) 774-1419 Evaluation Report 02768.03.06-R8 FL6332-R8 Revision 8: 10/12/2017 Page 5 of 9 • 10.2 Independent,Lar¢a Paddy: Nail through plastic cement Paddy (Beneath Tile) (when required) Underlayment 0 1. l+ \ lain. \ 0 6 eattensoptional Eave Course a � 1 l0 rn. Fascia 2 in Eave Closure Flat/Low Profile Tile .ram Exterior Research and Design, I.I.C. Cerdfm[e of Authorization N9503 10in.x � 1 in.wide Battens\ optional f Y Y Eave Course two - 10 in. 2in. I Battens High Profile Tile "�INITY ERD plasticcement Medium Profile Tile (Beneath Tlle) e EDITION (2017) FBC NON-HVHZ EVALUATION ICP Adhesives Polyset• AH-160; (888) 774-1419 weephole I ve closure idge K Eave Closure Fascla Evaluation Report 02768.03.06-RB FL6332-R8 Revision 8: 10/12/21317 Page 6 of 9 c 10.3 Interdependent, Two Paddy: Nail through plastic cement Paddy (between tiles) (when required) Battens optional ° ° Paddy(undertilel Single paddy y -e" ontop ofble Singlepaddr under til �- ngl � j Jerlayment ���- on underlay o 2x4in. It 10m4 Fascia 2 in Eave Closure Flat/Low Profile Tile `J TRINITY I ERD Nallthrough plastic cement Single paddy under tile (when required) Paddy(between tiles) Battens Paddy (under tile) optional ,+ Single paddy on top of tile� V4x 4in. v 2z4in.� Single paddy on undarlayment , + r• gave closure . Eave Course Fascia Medium ProfileTile Nallthrough plastic ce em Single paddy under tile (when required) Paddy (between tiles) Battens optional Paddy (under tile) •. � onglepaddy ym F,.a nunderla 4 x4 in. }� Single 2x4in paddy on topoftlla— uw Y �y� - Eave Course - Fascia Weephole 10in. "2 in. Eaveclasure Drip edge High Profile Tile 0 Exterior Research and Design, U.C. Evaluation Report 02768.03.06-RB cert/ilrate cfAuthorhatlon e9503 6m EDITION (2017) FBC NON-HVHZ EVALUATION F16332-RS ICP Adhesives Polyseto AH-160; (888) 774-1419 Revision 8: 10/12/2017 Page 7 of 9 `mot I RINITY I ERD 10.4 Two Piece Barrel (Cap & Pan) Tile: 11 Place enough adhesive to achieve 65 to 70 In contact with the pan tile. 21 Tum Comore.pale. down. Place adheciw 1R ht.lo t inch In rmm mcaldo oepo of cover tilt. ImLNcewrtilo. l Undarlayment (motarshown) Re move top portion of the eave course cover tile. Ab ut to second coun e a f pan tiles. Set ure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile 10.5 Hip and Ridge (independent placement): A beM once po4se'2AII.10 nosy la WIksl.1w" me loaki &s.f= Lwh Alive o."W, hµYAgaW dos FAidzed neW hart b pmidevtatImbhvida Exterior Research and Design, U.C. Evaluation Report 02768.03.06-R8 CertiPoore of Authorization N9503 6tnEDITION (2017)FBC N0N-HVHZ EVALUATION FL6332-R8 ICP Adhesives Polyseto AH-160, (888) 774-1419 Revision 8: 10/12/2017 Page 8 of 9 10.6 Hip and Ridge (interdependent placement): -END OF EVALUATION REPORT - '�INITY ERD Exterior Research and Design, U.C. Evaluation Report 02768.03.06-118 Certlpwte of Authorhation#9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-118 ICP Adhesives Polyseto AH-360; (888) 774-1419 Revision 8: 10/12/2017 Page 9 of 9