Loading...
HomeMy WebLinkAboutProduct Approval; Sectional Exterior Door Assemblies16116/2019 Florida Building Code Online s • ' 0 4 D 6 p/ '` ` • r' ME 71 BCIS Home Log In User Registration Hot Topics- Submit Surcharge Stats a Facts Publications Contaa Us BCIS Site Map Unks Search Flonda �� 1 E'.' Product Approval D Product Aper PraductAporoval Menu > Pmduceor Agplication Search > Agolication Llrt> Application Detail FL # FL9174-1112 Application Type Revision Code Version 2017 Application Status Approved Comments Archived _. Product Manufacturer Wayne -Dalton, a division of Overhead Door Corporation Address/Phone/Email 3395 Addison Drive Pensacola, FL 32514 (330)763-8121 dkomish@wayne-dalLon.com Authorized Signature Mark Garen Mark_Garon@Overheaddoor.com Technical Representative Mark Garen Address/Phone/Email 3395 Addison Dr. Pensacola, FL 32514 (850)474-9490 Mark_Garon@Overheaddooccom Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Gordon Thomas Evaluation Report Florida License PE-46718 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By Jeffrey R Arneson, P.E. 4 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL9174 R12 COI Gordon Tomas COI 2017.PDF Standard Year DASMA-108 2012 DASMA-115 2012 Florida Licensed Professional Engineer or Architect FL9174 R12 EDuiv WD2017-00IR2 Evaluation Repo[ - FL 9174.PDF Sections from the Code https://www.floridabuilding.org/prlpr_app_dg.aspx?param=wGEVXQwtDquFlIJRfWxf6u7ojn[OheH°/a2bKagdfe2PanfKY7e2Oj77uQ%a3d%n3d 1/5 16/16/2019 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved of Method 1 Option D 08/11/2017 01/02/2018 01/02/2018 02/13/2018 FL # Model, Number or Name Description 9174.1 5120 / 6100 / 9100 #0226 9' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0228-318958-P8 S.pd Approved for use outside HVHZ: Yes FL9174 R12 11 307494 P11 Track Supplement Chart signed.odf Impact Resistant: Yes FL9174 R12 II 324620 P16 lamb Connection Supp signed odf Design Pressure: +26.90/-30.80 Verified By: Gordon Thomas FLORIDA PE 46718 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-00IR2 Evaluation Report- FL 9174.PDF Created by Independent Third Party: Yes 9174.2 5120 / 6100 19100 #0229 16' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use In HVHZ: No FL9174 R12 II 0229-318959-P9 S.pd Approved for use outside HVHZ: Yes FL9174 R12 11 307494 P11 Track Supplement Chart sinaed,RQ( Impact Resistant: No FL9174 R12 LI 324620 P16 Jamb Connection Supp sloned.odf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Design Pressure: +15.30/-17.00 Other: Doors with glazing shall not be used In the wind- Created by Independent Third Party: Yes borne debris region unless protected or unless structure Is Evaluation Reports designed as partially enclosed or door is a replacement FL9174 R12 AE WD2017-001112 Evaluation Rel2ort - FL 9174.PDF Created by Independent Third Party: Yes door. 9174.3 5120 / 6100 / 9100 #0230 16' Max width. 8'-9" Max height. Max section height 21". Glazing _ available In top or Intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0230-318960-P10 S.pdf Approved for use outside HVHZ: Yes FL9174 R12 Ii 307494 P11 Track Supplement Chart sianed.odj Impact Resistant: Yes F1,9174 R12 II 324620 P16 Jamb Connection Suoo sip en d.odf Design Pressure: +25.90/-28.80 Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-00IR2 Evaluation Report- FL 9174.PDF Created by Independent Third Party: Yes 9174.4 5120 / 6100 / 9100 #0231 16' Max width. 8'-9" Max height. Max section height 21". Solid only - no glazing available. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0231-318996-P6 S.pd Approved for use outside HVHZ: Yes FL9174 R12 II 307494 P11 Track Supplement Chart signed.odf Impact Resistant: Yes FL9174 R12 IL 324620 P16 Jamb Connection Supp--sjgned.pdf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Design Pressure: +30.00/-33.50 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes borne debris region unless protected or unless structure is Evaluation Reports designed as partially enclosed or door is a replacement FL9174 R12 AE WD2017-00IR2 Evaluation Report - FL 9174.PDF door. Created by Independent Third Party: Yes 9174.5 5120 / 6100 / 9100 #0234 9' Max width. 8'-9" Max height. Max section height 21". Glazing available In top or Intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL2174 R12 II 0234-319022-P6 S.pdf Approved for use outside HVHZ: Yes FL9174 R12 fI 307494 Pll Track Supplement Chart sigOPdfLdf Impact Resistant: Yes FL9174 R12 II 324620 P16 Jamb Connection Supn Signed.odf Design Pressure: +43.20/-49.60 Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-001112 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 19174.6 5120 / 6100 / 9100 #023S 16' Max width. 8' Max height. Max section height 21". Glazing available in top or intermediate section. https://www.floridabuilding.org/pripr app_dtl.aspx?param=wGEVXQwtDqufllJRfWxf6u7ojnlOheH%2bKagdfe2PanfKY7e2Oj77uQ%a3d%3d 215 16/16/2019 Florida Building Code Online Limits of Use I Installation Instructions Approved for use In HVHZ: No FL9174 R12 II 0235-319023-P7 S odf Approved for use outside HVHZ: Yes FL9174 R12 II 307494 Pll Track Supplement Chart signgd,pdf Impact Resistant: Yes Design Pressure: +39.20/-43.70 FL9174 R12 II 319040 PI Post Istall Instructions signed pdf FL9174 R12 II 324620 P16 Jamb Connection Supp sianed.odf Other: Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports FI.4174 R12 AE WD2017-00IR2 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 9174.7 5120 / 9100 #0232 18' Max width. 8'-9" Max height. Max section height 21". Glazing available In top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0232-318999-P6 S,pdf Approved for use outside HVHZ: Yes FL9174 R12 II 307494 Pll Track Supplement Chart signed.pcif FL9174 R12 II 324620 P16 Jamb Connection Supp sicned. odf Impact Resistant: No Design Pressure: +12.40/-13.80 Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes tome debris region unless protected or unless structure is Evaluation Reports designed as partially enclosed or door is a replacement door. FL9174 R12 AE WD2017-001112 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 9174.8 5120 / 9100 #0233 18' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or Intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0233-319000-P6 S,pdf Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 R12 II 307494 Pll Track Supplement Chart signed,pdf FL9174 R12 II 324620 P16 Jamb Connection Supp slaned.odf Design Pressure: +18.50/-20.70 Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes tome debris region unless protected or unless structure is Evaluation Reports designed as partially enclosed or door is a replacement FL9174 R12 AE WD2017-001112 Evaluation Report- FL 9174.PDF Created by Independent Third Party: Yes door. 9174.9 5120 / 9100 #0236 18' Max width. 8' Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0236-319024-P7 S,pdj Approved for use outside HVHZ: Yes FL9174 RI? IT 307494 Pll Track Supplement Chart signe .pdf Impact Resistant: Yes FL9174 R12 11 319040 PI Post istall Instructions signed.pdf Design Pressure: +30.00/-33.50 FL9174 R12 11 324620 P16 Jamb Connection Supp gWned.odf Other: Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports j FL9174 R12 AE W02017-001R2 Evaluation Report - FL 9174,PDF Created by Independent Third Party: Yes 9174.10 5120 / 9100 #0237 18' Max width. 8' Max height. Max section height 21". Glazing available In top or intermediate section. Limits of Use Installation Instructions Approved for use In HVHZ: No FL9174 R12 If 0237-319025-P7 S pdf Approved for use outside HVHZ: Yes FL9174 R12 11 307494 P11 Track Supplement Chart signed.pdf FL9174 R12 11 319040 Pl Post Istall Instructions signed.gdf Impact Resistant: Yes Design Pressure: +39.20/-43.70 FL9174 R12 II 324620 P16 Jamb Connection Suoo signed,pdf Other: Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE D 017-001117 Evaluation Report - FL 9174,PDF Created by Independent Third Party: Yes 19174.11 5120/5140/6100/9100/9400/9600 9' Max width. 10' Max height. Max section height 24". Glazing #0600 available In top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0600-319026-P5 S.pdf Approved for use outside HVHZ: Yes FL9174 R12 fI 307494 P11 Track Supplement Chart slgnn,edpdj Impact Resistant: No FL9174 R12 Ii 324620 P16 Jamb Connection Supp signed odf Design Pressure: +26.90/-30.80 j Other: Doors with glazing shall not be used in the wind- Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes bome debris region unless protected or unless structure is Evaluation Reports j designed as partially enclosed or door is a replacement FL9174 R12 AE WD2017-00I112 Evaluation Report - FL 9174,PDF Created by Independent Third Party: Yes 1 door. 19174.12 5120/5140/6100/9100/9400/9600 9' Max width, 10' Max height. Max section height 24" Glazing #0601 available in top or Intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0601-319027-PS S,pdf Approved for use outside HVHZ: Yes FL9174 R12 II 307494 P11 Track Supplement Chart signed pdf https://www.floridabuilding.org/prlpr_app_dfi.aspx?param=wGEVXQwtDqufllJRfWxf6u7ojni0heH°/"2bKagdfe2PanfKY7e2Oj77uQ°/"3d%3d 3/5 10/16/2019 Florida Building Code Online Impact Resistant: Yes FL9174 R12 II 324620 P16 Jamb Connection Sup"gned.odf Design Pressure: +41.00/-46.30 Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Other: Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-00IR2 Evaluation Report- FL 9174 PDF Created by Independent Third Party: Yes 9174.13 15120/5140/6100/9100/940019600 #0602 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.30/-17.00 Other: Doors with glazing shall not be used in the wind- borne debris region unless protected or unless structure is designed as partially enclosed or door is a replacement door. 9174.14 15120/5140/6100/9100/9400/9600 #0603 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +23.00/-25.00 Other: Doors with glazing shall not be used in the wind- borne debris region unless protected or unless structure is designed as partially enclosed or door is a replacement door. 9174.15 15120/5140/6100/9100/9400/9600 #0604 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +39.20/-43.70 Other. 16' Max width. 10' Max height. Max section height 24". Glazing available In top or Intermediate section. Installation Instructions FL9174 R12 If 0602-319028-P6 S.odf FL9174 R12 IT 307494 Pll Track Supplement Chart signed.pdf FL9174 R12 II 324620 P16 Jamb Connection Supp ned.pddf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE W02017-001112 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 16' Max width. 10' Max height. Max section height 24". Glazing available In top or Intermediate section. Installation Instructions FL9174 R12 II 0603-319029-PB S.pdf FL9174 R12 II 307494 Pll Track Supplement Chart slgned.Rd FL9174 R12 11 324620 P16 Jamb Connection Supp3Lgned.odf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-001112 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 16' Max width. 8' Max height. Max section height 24" Glazing available in top or Intermediate section. Installation Instructions FL9174 R12 fl 0604-319030-P6 S.pol FL9174 R12 11 307494 P11 Track Supplement Chart signed.pdf FL9174 R12 If 319040 PI Post Istall Instructions sigOQ2pd1 FL9174 R12 If 324620 P16 Jamb Connection Suoo signed.ndf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-00IR2 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 9174.16 5120/5140/6100/9100/9400/9600 18' Max width. 10' Max height. Max section height 24". Glazing #0605 1 available in top or intermediate section. Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.30/-17.00 Other: Doors with glazing shall not be used in the wind - home debris region unless protected or unless structure is designed as partially enclosed or door is a replacement door. Installation Instructions FL9174 R12 11 0605-319031-PS S.pd FL9174 R12 if 307494 P11 Track Supplement Chart signed pdf FL9174 R12 If 324620 P16 Jamb Connection Supp_pignen d.pdf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-00IR2 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 9174.17 15120/5140/6100/9100/9400/9600 118' Max width. 8' Max height. Max section height 24" Glazing #0606 available in top or Intermediate section. Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30.00/-33.50 Other: Doors with glazing shall not be used in the wind- borne debris region unless protected or unless structure Is designed as partially enclosed or door is a replacement door. Installation Instructions FL9174 R12 11 0606-319032-P7 S.pdt FL9174 R12 II 307494 Pll Track Supplement Chart sinned pdf FL9174 R12 If 319040 PI Post (stall Instructions signed.odf FL9174 R12 11 324620 PI6 Jamb Connection Supp signed.odf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes Evaluation Reports FL9174 R12 AE WD2017-001R2 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 9174.18 5120/5140/6100/9100/9400/9600 IS' Max width. 8' Max height. Max section height 24" Solid only - #0609 no glazing available. Limits of Use Installation Instructions Approved for use in HVHZ: No F1,9174 R12 II 0609-319035-P6 S.pdf Approved for use outside HVHZ: Yes FL9174 R12 II 307494 PIT Track Supplement Chart sip en d.odf Impact Resistant: Yes FL9174 R12 II 319040 PI Post Istall Instructions signed.odf Design Pressure: +39.20/-43.70 FL9174 R12 Ii 324620 P16 Jamb Connection Supp signed pdf Other: Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Created by Independent Third Party: Yes hips:ltwww.floddabuilding.org/prlpr app_dd.aspx?pamm-xGEVXQwtDquflIJRfWxf6u7cinl0heH%2bKagdfe2PanfKY7e2Oj77uQ%3d°/,3d 4/5 10116/2019 Florida Building Code Online Evaluation Reports E 9174 R12 AE WD2017-OOIR2 Evaluation Report - FL 9174.13DF Created by Independent Third Party: Yes 9174.19 5140/6100/9400/9600 #0608 18' Max width. 8'-9" Max height. Max section height 21e. Glazing available In top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 II 0608-319034-PS S.pd( Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 1112 II 307494 Pll Track Supplement Chart sipLed,pd I FL9174 R12 IT 324620 P16 Jamb Connection Supo sioned.odf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Design Pressure: +18.50/-20.70 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes home debris region unless protected or unless structure is Evaluation Reports designed as partially enclosed or door is a replacement door. FL9174 R12 AE WD2017-001R2 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes 9174.20 5140/9400/9600 #0607 16' Max width. 8'-9" Max height. Max section height 21". Glazing available in top or intermediate section. Limits of Use Installation Instructions Approved for use in HVHZ: No FL9174 R12 fI 0607-319033-P6 S.pd Approved for use outside HVHZ: Yes Impact Resistant: No FL9174 R12 II 307494 Pll Track Supplement Chart signed.pd FL9174 R12 II 324620 P16 Jamb Connection Supo sianed.odf Verified By: Gordon Thomas P.E. FLORIDA PE 46718 Design Pressure: +25.90/-28.80 Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes borne debris region unless protected or unless structure is designed as partially enclosed or door is a replacement I door. Evaluation Reports FL9174 R12 AE WD2017-00SR2 Evaluation Report - FL 9174.PDF Created by Independent Third Party: Yes sack Next Concert cos :: 2601 Blair Stone Road Tallahassee Fl. 32399 Phone: 85p-487-1924 The State of Florida is an AA/Eeci employer. fggydaht 2007-2013 State of Florida.:: PHyaQy Statement :: Accesslbiliw Statement:: Refund statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(I), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which ran be made a Callable to the public To determine If you are a licensee under Chapter 455, F.S. please dick hem . product Approval Accepts: W W ® Ed "Se�clMityrkl https://www.floridabuilding.org/prlpr app_df.aspx?param=wGEVXQwtDqufllJRfWxf6u7ojni0heH°/a2bKagdfe2PanfKY7e2Oj77uQ°/a3d°/a3d 5/5