.. FL 1k FL16094-R6
Application Type Revision
Code Version 2017
Application Status Approved
-Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archlved
Product Manufacturer Plastpro Inc. / Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
LOS ANGELES, CA 90045
(440) 969-9773 Ext 16
rickw@mbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldg consultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles, CA 90045
(440) 969-9773 Ext 18
scotUohnson@plastproinc.com
Quality Assurance Representative Ron O'Connell
Address/Phone/Email 5200 W Century Blvd.
Los Angeles, CA 90045
(440) 969-9773 Ext 16
ronoconnell@plastpro.com
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency
National Accreditation & Management Institute
Validated By
Ryan J. King, P.E.
d Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1929
1996
ASTM D2843
1999
ASTM D535
1998
ASTM D638
2003
ASTM E84
2005
ASTM G26
1995
TAS 201, 202, 203
1994
Equivalence of Product Standards
Certified By
Florida Licensed Professional Engineer or Architect
FL16094 R6 Eq i1 iv (S)-Equivalency of Standards.(Zd[
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr°/2fJncsBYUfaptVgS%2bntnnAaT2MGuAQpu6w%3d°/a3d 114
10116/2019
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Method 1 Option A
10/15/2017
10/15/2017
Date Approved 10/25/2017
Pummary of Products
FL # i Model, Number or Name Description
16094.1 a. Smooth/Wood 6'8 Glazed Fiberglass Single Door Panel with and without
Grain/Rustic/Mahogany Series N Sidelites - Inswing/Outswing (X, OX or XO and OXO
Fiberglass Door Configurations) (Note: Door panel is a wood stiles / composite
rails with fiberglass cladding)
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 16094.1 for Design Pressure Ratings, any
additional use limitations, Installation Instructions and product
particulars.
Certification Agency Certificate
FLI6894 R6 C CAC (g) NAMI CERT 16094.1.pdf
Quality Assurance Contract Expiration Date
01/31/2019
Installation Instructions
FL16094 R6 II (c) Inst 16094.1,pdff
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL16094 R6 AE (c) Eval 16094.1.pdf
Created by Independent Third Party: Yes
16094.2
b. Smooth/Wood
6/8 Glazed Fiberglass Double Door Panel with and without
Grain/Rustic/Mahogany Series N
Sidelites - Inswing/Outswing (XX and OXXO Configurations)
Fiberglass Door
(Note: Door panel is a wood stiles / composite rails with
Rberglass cladding)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16094 R6 C CAC (g) NAMI CERT 16094.2.pddf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes -
01/31%2019
Design Pressure: N/A
Installation Instructions
Other: See INST 16094.2 for Design Pressure Ratings, any
FL16094 R6 II (c) Inst 16094.2.pdf
additional use limitations, Installation instructions and product
Verified By: Lyndon F. Schmidt, P.E. 43409
particulars.
Created by Independent Third Party: Yes
Evaluation Reports
FL16094 R6 AE !c) Eval 16094.2.pdf
Created by Independent Third Party: Yes
16094.3 c. Smooth/Wood B'0 Glazed Fiberglass Single Door Panel with and without
Grain/Rustic/Mahogany Series N Sidelites - Inswing/Outswing (X, OX or XO and OXO
Fiberglass Door Configurations) (Note: Door panel is a wood stiles / composite
rails with fiberglass cladding)
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: N/A
Other: See INST 16094.3 for Design Pressure Ratings, any
additional use limitations, installation Instructions and product
particulars.
Certification Agency Certificate
FL16094 R6 C CAC A) NAMI[ CERT 16094.3,pdd(
Quality Assurance Contract Expiration Date
01/31/2019
Installation Instructions
FL16094 R6 II (c) Inst 16094.3.odf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL16094 R6 AE (c) Eval 16094.3.1df
Created by Independent Third Party: Yes
16094.4
d. Smooth/Wood
8'0 Glazed Fiberglass Double Door Panel with and without
Grain/Rustic/Mahogany Series N
Sidelites - Inswing/Outswing (XX and OXXO Configurations)
Fiberglass Door
(Note: Door panel is a wood stiles / composite rails with
Rberglass cladding)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16094 R6 C CAC (p) NAMI CERT 16094.4.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
01/31/2019
Design Pressure: N/A
Installation Instructions
Other: See INST 16094.4 for Design Pressure Ratings, any
FL16094 R6 II (c) Inst 16094.4.pdf
additional use limitations, installation instructions and product
Verified By: Lyndon F. Schmidt, P.E. 43409
particulars.
Created by Independent Third Party: Yes
Evaluation Reports
https://www.floridabuilding.org/prlpr_app_ l.aspx?param=wGEVXQwtDgtFPmdYNDWr%2fJncsBYUfaptVgS%2bntnnAaT2MGuAQpu6w°/3d%3d 214
10/16/2019
Florida Building Code Online
FL16094 R6 AE (C) Eval 16094.4.pjf
Created by Independent Third Party: Yes
16094.5 e. Smooth/Wood
6'8 Opaque Fiberglass Single Door Panel with and without
Grain/Rustic/Mahogany Series N
Sidelites - Outswing (X, OX or XO and OXO Configurations)
Fiberglass Door
(Nate: Door panel is a wood stiles / composite rails with
fiberglass cladding)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16094 R6 C CAC (b) NAMI CERT 16094.5.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
01/31/2020
Design Pressure: N/A
Installation Instructions
Other: See INST 16094.5 for Design Pressure Ratings, any
FL16094 R6 11 f;) Inst 16094.5.pdf
additional use limitations, installation instructions and product
Verified By: Lyndon F. Schmidt, P.E. 43409
particulars.
Created by Independent Third Party: Yes
Evaluation Reports
FL16094 R6 AE (c) Eval 16094.5.pdf
Created by Independent Third Party: Yes
16094,E
f. Smooth/Wood
618 Opaque Fiberglass Double Door Panel with and without
Grain/Rustic/Mahogany Series N
Sidelites - Outswing (XX and OXXO Configurations) (Note: Door
Fiberglass Door
panel is a wood stiles / composite rails with Fiberglass cladding)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16094 R6 C CAC f�) NAMI CERT 16094.6.pd
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
01/31/2020
Design Pressure: N/A
Installation Instructions
Other: See INST 16094.6 for Design Pressure Ratings, any
FL16094 R6 II (5) Inst 16094.6.pd
additional use limitations, installation instructions and product
Verified By: Lyndon F. Schmidt, P.E. 43409
particulars.
Created by Independent Third Party: Yes
Evaluation Reports
FL16094 R6 AE (y) Eval 16094.6.pd
Created by Independent Third Party: Yes
I
16094.7
g. Smooth/Wood
Grain/Rustic/Mahogany Series N
8'0 Opaque Fiberglass Single Door Panel with and without
Sidelites - Outswing (X, OX or XO and OHO Configurations)
Fiberglass Door
(Note: Door panel is a wood stiles / composite rails with
fiberglass cladding)
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL16094 R6 C CAC (b)_NAMI CERT 16094.7.pd
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
01/31/2020
Design Pressure: N/A
Installation Instructions
Other: See INST 16094.7 for Design Pressure Ratings, any
FL16094 R6 tI (4) Inst 16094.7. odf
additional use limitations, Installation Instructions and product
Verified By: Lyndon F. Schmidt, P.E. 43409
particulars.
Created by Independent Third Party: Yes
Evaluation Reports
FL16094 R6 AE fy) Eval 16094.7.pdf
Created by Independent Third Party: Yes
... ------
16094.8 h. Smooth/Wood
___.... ............................ ._...._......
8'0 Opaque Fiberglass Double Door Panel with and without
Grain/Rustic/Mahogany Series N
Sidelites - Outswing (XX and OXXO Configurations) (Note: Door
Fiberglass Door
panel is a wood stiles / composite rails with fiberglass cladding)
Limits of Use
Approved for use in HVHZ: Yes
Certification Agency Certificate
FL16094 R6 C CAC (b) NAMI CERT 16094.8.p 1Lf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
01/31/2020
Design Pressure: N/A
Installation Instructions
Other: See INST 16094.8 for Design Pressure Ratings, any
additional use limitations, installation Instructions and product
FL36094 R6 tl (L) Inst 16094.8,W
Verified By: Lyndon F. Schmidt, P.E. 43409
particulars.
Created by Independent Third Party: Yes
Evaluation Reports
FL16094 R6 AE (6) Eval 16094.B.pdf
Created by Independent Third Party: Yes
back Nuvt
F[7,i2T[S2FT�,c IF6 , _ 'tea LLl7Sd1F.A.7.ial'y6efil
The State of Florida Is an AA/EEO employer. Cggyllght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility. Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a Public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide Me Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.s., please click h1;.
Product Approval Accepts:
0 ® H 12
https://www.floddabuilding.org/prlpr_app_ g.aspx?param=wGEVXQvdDgtFPmdYiNDWr%2fJncsBYUfaptVgSa/o2bntnnAaT2MGuAQpu6w%3d%p3d 3/4
10/16/2019
Florida Building Code Online
.q
seccirityniErnicsC
https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr%2fJncsBYUfaptVgS%2bntnnAaT2MGuAQpu6w%3d%3d 414
plastprb
37 IDTH _
FRAMERAMS WIDTH
5200 W. CENTURY BLVD.
LOS ANGELES, CA 90045
i
QS 2
OPAQUE FIBERGLASS SINGLE DOOR
6 ° 2
w/ or w/out SIDELITE(S)
Outswing
a a
"IMPACT"
GENERAL NOTES
1. This product anchoring drawing has been developed and is in compliance with the 6th Edition 12017) Florida Building
Code (FBCJ structural requirements Including the "High Velocity Hurricane Zone (HVHZi. See the Certification Agency
Certificate forstres, specifications and rating.
2. Product anchors drag be as Wed and spaced as shown on details. Anchor embedment to base material shop be
beyond wail dressing or stucco.
3. When used In the'HVHr this product complies vrithSection 1626 of the Florida Balding Code and does not require an
Impact resistant covering.
4. When used in areas outside of the'HVHr requiring wind borne debt protection this product compries With PIC
Sections 1609.12 A R301.2.1.2 and does not require an Impact res6lont covering. This product meets misole level V
and Includes Wind Zane 4 as defined In ASTM E 1996 and FBC Sections 1609.1.22 & R301.2.1.2.1.
5. For 24stud construction, anchoring of these units shag be the some as that shown fw2c buck mosorvyconstruction.
6. Site
condtions that deviate from the detab of this droving require further engineeringanalysis by a licensed engineer
or registered architect.
7. Outswing configurations ut2king the high dam s0 (see Section 413). meet Water Infiltration requirements for'HVHr. All
other configurations do not meet the water brRuction requirements for the `HVHr and must be installed only In
nmo-hobitoble areas or at habitable locations protected by an overhang or canopy wch that the angle between the
edge of canopy or overhang to sil6 tens than 45 degrees.
TABLE OF CONTENTS
SHEET#
DESCRIPTION
I
Typical elevations. design pressures&general notes
2
Hodwntalcrossrecilons
3
Vertical cross sections
4
Buck anchoring & big of matedab
5
Frame anchoring & glazing details
s
1 75° MAX. OVERALL _..4
t-- 112,7MAX OVERALL FRAME WIDTH
J 3
5
2
0
o
LLLI
J—
v vv
v
CONFIGURATION
MAX.
FRAME
DIMENSION
DESIGN PRESSURE (PST)
POSITIVE
NEGAi1VE
x
37.5" x 96.75"
xo/m
75.D" x 96.75"
OXO
112.5"x 96.75"
FL-16094.7
B\Ulenu\Mastp%McPFPAfAM2-floeWa Product ApWmis\FL-1fi09aNSenes WV ImpxhC-Onw'yVL-16091 (Z01))\R-1fi09CS8tlnq]3
Ee
W
N N
O
xg ON _\
O A
Z . a
o Zy
A
o z
N [lJ y
O
®S a
D0
n 1
�O 3
�n t
n^
OA y
T
N D
O N W IF2 Q P
Z O
A
O
O z�
O
Z n
\J
M A
O N •
'a
o A J�uwmMi
p� , / •'T
Na 43409
October 14, 2017
PROWCR: Ixcumsma Pr.Pona ey:
I i Ot P P.C.
Ne.F6JdOB :dt
INe m z o Fie Reuss IOOOR
g y q 2 t0 10 I) UPOA]E i0 61N ED. 201]) FBC IFS PART OR ASSEMBLY: �/C BUIWINC CONSULTA S. INC.
Id >; iu 1 09 02 15 UPDATE TO SIN ED. 2016 IBC tF9 ✓1• P.O. Boa 2J0. Valtico. FL 00595
� w NO DATE OY HORIZONTAL W P.O. No.: 0. Valr9.919]
REVISIONS CROSS SECTIONS POPE C.A. No. 9813
0.1UentVP slprq Nc P6RM EN -RorWa p uce Approvals\N-160M N Senes WHZI pacNC- DrawingWL-1609A (ID17)1fL-16M5-Adw 33
m
1-1/d'MW.
EMB.(TYP.)
m
114
A
y
n
rp
0
413i
rp
0
l
0
0
A
z
0
�)
Q
A
Z
•p•
n
1-1IC1MrvIN.
EMB. ITYP.)
0
m
ma
�
m
0
A
q �
E A
� 0
3
0
m
O
m
A
0
A
EMB. (IYP.)
1-1/CHIN.
u m
EMB. (IYP.)
6O
fYN
m
•
Z
N
H
H
0
I0
n
o
u
z
A
•
;yNJI �
0
1-1/4'MB1. A
z
FMB. (IYP.)
m
A
`L11111111111I],!
.o VA....
o
piv,
v V6ENDff •;T
N6.434p8
G /,2017
October 7-'. .-
Y
=
PRODUCT:
po•vx.^1a Pr•Por•a e!- ,(•�
Lyn F. scww;et %nsl •.t0ino�.:'G\=���
r"-
P/.�E No. 43409 ry/
Iw
0
m
0 "
2
L,
O
m 2
FlBERCV55 DOOR
,/ONAIto�\
•/` BUILDING CONSULTANTS, INC.
QATE
UPDAIE TO 61H ED. 2017
FBC
U5
PART OR ASSEMBLY:
UP60TE TO SRI E0.
POI4
FfiC
fi5P.O.
Bea 210. Valnco, FL W595
BY
CROSS SEECITONS
Pl+ono No.: 813.659.9197
REVISIONS
FBPE CA No. 9813
O am
a n.w.
euno�xo
coxouwAxro Ix e.
IT
MASONRY P. HEAD
OPENING &JAMBS
'L(BUCK _ —
BUCK ANCHORING
x
SUCKANCHORING
xO/Ox
BILLOFMATERIAIS
g&NR
Doco om
MAmm
A
1X BUCK JSG>=OM)
WOOD
B
2X BUCK [SG >=OM)
WOOD
C
1/4"MAX. SHIM SPACE
D
1/4" X 2-3/4" PFH ITW CONCRETESCREW
STEEL
E
MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90
CONCRETE
G
1/4"X33/4" PFH ITW CONCRETE SCREW
STEEL
H
3/16"x3-1/4'PFH TIW CONCRETE SCREW
STEEL
K
#9X3/4'PFH WOOD SCREW
STEEL
l
#BX3"PFHWOOD5CREW 1-1/2MIN. EMBEDMENT)STEEL
M
#10 X2-1/2' PFH WOOD 5CREW
STEEL
I
FINGER JOINTED PINE HEAD&JAMB I5G>=0.421
WOOD
JAMBS (TYP.) _ U •j a �[
TYPO f.., .. ".. I 1' IIYP.)
!r
2X BUCK J
MASONRY
OPENING
D
�
I
I _
I
- TYP. HFAO
I
I -
&JAMBS
I
I
I
I
I
I
I
I
SUCKANCHOMNG
OX0
CONCRETE ANCHOR NOTES:
I. SubsRNibnorepudconcreteanciprs Eom atld(emnfapWermMMre CJIareNeage
mtlanro antl canter tl1#m�ce mpldemenN.
z Contaefa gncUnbcafrom cl me canon aW oo aajuifatl romainroN mo mfn. atlge
mtrafro bmafa/dnh Conaefe onrabco=-;=- MAK O.C. HYPJ"mull be
ad(urtetlromoMMin Rn I edge O.C.
P.)" a. . aJNibrolcoria. anUm
may0e requbatl ro omara fro Y+AC O.C. f0.P.1.6mandw as rol eaeotletl.
9. ConaeteanchafaWe:
?ANCHOR
ANCHOR
fM1N ;;
MIN„CIFARANCETQ
;MIN. COARANCE
'r TYPE
SItE'¢ S
FMBF,OMFM_'.
MA;ONRYFRGEx
ADJgCENIANtHOR'
fL-16094.7
w
4.7 MASONRY
(9XBUCK 2
TYP. HEAD
&JAMBS _Ci FFRAA
7X BI
PANEL-
qS MASONRYrq
OPENING 4S
.;
4S
--{
L BUCK
G I%BUCK
TYP.HEAD
�L
&JAMBS
—(
M
E
TYP.@
BACK-TO-BACK
CK
JAMBS
D TYP.
51L
) r
l 1 L
DYP.I
JAMBS (1YP.) P EL
OPENING
4sDYP.)
-..-4S DYP.)
r AN (TYP'
I
••
1 -
l BUCK
I I
M
-1 I I
G Ix BUCK
7YP.®
—
TYP.HFAD
BACK-TO-BACK
&JAMBS
JAMBS
1CK
D TYP.
SRL
FRAME ANCHORING
FRAMEANCHORING
HINGEJAMB fRAMEANCHORING
XO/OX
OXO
X
UCONE
GOW
9951
(DGW 995)
UTT
5/8'GIASSBGE
HINGE
WGE \
ODLALUMINUM
BACK-BEDDINGSIUCONE
LTIE FRAME
(READISEAL)
1'OVERALL GLASS THK.
1/B' ANNEALED GLASS
CONCRELEANCHOR NOTES:
I, suosBlvlbn o/equatcmaete archon bane GNerenlwppaermoynava tlBruenreege
D.WP PVB INTERLAYER (KURARAYJ
defoxe mdaenrertllsfanmamauvamenR
2 Corwata ancharbcctbru ar Ma corners moy Ee r#W btl tomWnraln tnemh edge
I/8'ANNEALED GLASS
as fro mafara4�i me m.,�fs eae aaaarrommarJdnh. atlaid>namaae ecna�
Ab R SPACE
1/8' TEMPERED GLASS
L BACI
maybe maeimtl to amve the TlAX O.G frml'tlimensbn are ral exseded.
a Concete onchuroble:
MT.
A8%IS PH SMS
ALUMINUM SPACER
H 1%BL
'HARDWARE iABIF
MANUFACNRLTt
, MODE4 _
KYAKSFt
KNOB: SIGNANRE SERIFS
DEAOeOU: SIGNATURE SERIES (90D)
ANGHbR
ANCHbR
MIN%
MIN[LEA'AAN[ETO
MIc(EARAN[EJO;
TYPE
/5'NE
EA/BEDh1EM
MASONRYEOGE
ADNJACFMAN[HOR ':
IPH o
iAPCON
1/4'
ld/4'
S
4'
iAPOONo
BACK-BEDDINGSIUCONE DEADBOLT M
Gl 6UFIHG DRAn (RFADI-SEAL) STRIKE PLATE
O
LATCH STRIKE
WOODSCREWINSTAIfA110NNO1FS: PLATE
I.Mamran aminvmxn 5/Sedge d6fanre. I'enCCulwica, E 1'o.c spachgo/
pn:re ,fig IAICXAND DEA080LTDETAIL
wmmtl)aevq ro MMe olwul.
i
Ciyp`
� U
mm
9
r_
'gIj111P
u r. •;
m r
KENO
cW
mQLO
66LL
L
c LL
SWRE JAMB
JAMB
HINGE DEfA1L
YBACK JAMB
-'o
0
'z
m JX m
m LFS rz
ulu,L IA:
FL-16094.7 0
°n
¢ 5 ar 5 0