HomeMy WebLinkAbout Product Approval . - .a,. � _ r PLANNING & DEVELOPMENT
BOARD OF �'° ` r `' SERVICES DEPARTMENT
COUNTY
COMMISSIONERS . , .
Building and Code Regulation
Division
GAS PIPING SCHEMATIC
[A2] [A4] [A6]
[L4] [L8] [1.12]
TANK L1 1-3 L5 1.7 1.9 L11
SIZE
L2] [L6] [L10]
[Al] [A3] [A5]
TANK SIZE: 2 50 GALS.
APPLICANCE -TYPE/SIZE
Al BTU
A2 BTU
A3 BTU
A4 BTU
A5 BTU
A6 BTU
PIPING LENGTH &SIZE , (PIPE SIZE WAS TAKEN FROM
L1 (2 _FT. INCH DIA. THE 2014 FBC FUEL GAS CODE-
L2 3 ' FT. Pl INCH DIA. TABLE402( �)
L3 12' FT. I INCH DIA.
L4 1-f FT. 3 q 'INCH DIA.
L5 (Q FT. 4q INCH DIA.
L6 FT. INCH DIA.
L7 FT. INCH DIA.
L8 FT. INCH DIA.
L9 FT. INCH DIA.
1-10 FT. INCH DIA.
1-11 FT. INCH DIA.
L12 FT. INCH DIA.
Website:www.stlucieco.aov
2300 Virginia Avenue-Fort Pierce,FL. 34982-5652
Phone(772)462-1553 FAX(772)462-1578
Revised 7/22/14
I
I
Natural Gas Pipe Sizing Chart
Length of Size of Pipe in Inches
Pipe In Feet 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"
10 108 230 387 793 1237 2259 3640 6434
20 75 160 280 569 877 1610 2613 5236 9521
30 61 129 224 471 719 1335 2165 4107 7859
40 52 110 196 401 635 1143 1867 3258 6795
50 46 98 177 364 560 1041 1680 2936 6142
60 42 89 159 336 513 957 1559 2684 5647
70 38 82 149 317 476 896 1447 2492 5250
80 36 76 140 239 443 840 1353 2315 4900
90 33 71 133 275 420 793 1288 2203 4667
100 32 68 126 266 411 775 1246 2128 4518
125 28 60 117 243 369 700 1143 1904 4065
150 25 54 105 215 327 625 1008 1689 3645
175 23 50 93 196 303 583 993 1554 3370
200 22 47 84 182 280 541 877 1437 3160
300 17 37 70 145 224 439 686 1139 2539
Natural Gas flow is given in thousands of BTU/hr. - One cubic foot of LP gas=1000 BTU
Nominal pressure at the burner for Natural Gas is 3.5"of water column. (Typical machine supply 5"-71l)
Pipe length must include additional length for all fittings. Add approximately 5 feet of pipe per fitting
Natural Gas Example: A machine with a burner that requires 440,000 BTU would need a 1 AW pipe for
a 20'long run.
Liquid Propane Gas Pipe Sizing Chart
Length of Size of Pipe in Inches
Pipe in Feet 1/2" 3/4" 111 1-1/4" 1-1/2" 2" 2-1/2" 3" 4"
10 275 567 1071 2205 3307 6221 10140 17990 35710
20 ^ 189 393 732 1496 2299 4331 7046 12510 25520
30 152 315 590 1212 1858 3465 5695 10110 20620
40 129 267 504 1039 1559 2992 4778 8481 17300
50 114 237 448 913 1417 2646 4343 7708 15730
60 103 217 409 834 1275 2394 3908 6936 14150
80 89 185 346 724 1086 2047 3329 5908 12050
100 78 162 307 630 976 1811 2991 5309 10830
125 69 146 275 567 866 1606 2654 4711 9613
150 63 132 252 511 787 1496 2412 4281 8736
200 54 112 209 439 665 1282 2083 3618 7382
250 48 100 185 390 590 1138 1808 3210 6549
300 43 90 168 353 534 1030 1637 2905 5927
350 40 83 155 325 491 947 1505 2671 5450
400 37 77 144 303 i 458 887 1 1404 2492 5084
LP Gas flow is given in thousands of BTU/hr. - One cubic foot of LP gas-2516 BTU
This chart refers to low pressure LP,after regulation Standard nominal pressure at the burner for
Liquid Propane Gas is I V of water column.
Pipe length must include additional length for all fittings. Add approximately 5 feet of pipe per fitting
LP Example: A machine with a burner that requires 440,000 BTU would need a 1"pipe for a 20'long run.
Fuel Conversion/Gas Connections
Natural Gas Pipe Sizing
To determine correct NG pipe size, find the kW rating of NOTE: See Table B.3.2 in NFPA 54 or Table A.2.2 in the
generator in the left column, and trace to the right. The ICC IFGC, Equivalent Lengths of Pipe Fittings and
number to the right is maximum length (measured in ft/ Valves for the correct values to be added to overall fuel
m)allowed for the pipe sizes on top. Pipe sizes are mea- piping length. Tables are based on schedule 40 black
sured by trade size diameter to include any fittings, pipe. If installing any other piping system,follow pipe siz-
valves(must be full flow), elbows, tees, or angles. ing charts for selected piping system.
Table 5-1. NG Pipe Sizing
r For 5-7 in Water Column For 3.5-5 in Water Column
4} u (1.24-1.74 kPa) (0.87-1.24 kPa)
sP�pe Size,
Allowable Pipe Distances(ft I m)
IA
tF 5113 x 0 75`'119 1 f 25° 1251t321513$ a 76t/1$ ry I l;ZS { 25 f332� j 16,f>38
10kW 10/3.1 60/18.3 200/61 750/228.6 - 20/6.1 60/18.3 175/53.3 -
13116 kW - 10/3.1 55/16.7 200/60.9 450/137.1 - 30/9.1 125/38.1 200/61
20kW - 10/3.1 35/10.7 140/42.3 300/91.4 - 10/3.1 60/18.3 125/38.1
22kW - 10/3.1 30/9.1 115/35.1 250/76.2 - 10/3.1 60/18.3 125/38.1
LP Gas Pipe Sizing
o determine correct LP gas pipe size, find the kW rating NOTE: Pipe sizes are from the outlet of the second
of generator in the left column, and trace to the right.The stage regulator to the fuel shutoff valve. Table is based
number.to the right is maximum length (measured in ft/ on schedule 40 black pipe. If installing any other piping
m) allowed for pipe sizes on top. Pipe sizes are mea- system,follow the pipe size charts for the selected piping
sured by trade size diameter to include any fittings, system.
valves (must.be full flow), elbows, tees, or angles. See NOTE: Recommended minimum LP tank size is 250 gal
Table B.3.2 in NFPA 54 or Table A.2.2 in the ICC IFGC, (946 L). Contact LP provider to correctly size LP tank to
Equivalent Lengths of Pipe Fittings and Valves for the generator. Vertical tanks, which are measured in pounds
correct values to be added to overall fuel piping length. (or kilograms), are permitted if correctly sized for the gen-
erator. Do not connect generator to a 20 or 30 Ibs LP
tank.
Table 5-2. LP Gas Pipe Sizing
For 10-12 in Water Column
(2.49-2.99 kPa)
Allowable Pipe Distances(ft/m)
0 5/:13r 0 75 l 19� t �° 1/25 y 25 t32
10kW 30/9.1 175/53.3 400/121.9 -
13/16 kW - 80/24.4 350/106.7 600/182.9
20122 kW - 40/12.2 175/53.3 550/167.6
3f f
Installation Guidelines for 60 Hz Air-Cooled Generators 23
�11/U>
�`
�:�
r�
,�..�
n�. -�
i ..
, ;
j.,
it,�,$ } 1
r �
1� ,�'i.� sa--r. � EY;���
� �
�;f}fi F (� �A�S�1w;r �.
t�t
�� ��
1V ¢ ,,W v r,� �r v.
�.<
l�� r tiE��
t .�, t...t i � 'S
4�y � 1 �:.4�, i
"�ca a 'a
h},~�� k n � ,�
_ °h-hrs.
'!�` �•n
!I
��,
a.:
y«
.:�%�
n� V t�
/,�•
4..
5�,
si:� ��.
h
lr
��
°r
. . }
8
F
7 i
r
lb
t
......
f
`t
'1
1
l
V
.r
zs''
r
..r
1 /
l
. I
LEGAL DESCRIPTION
Lot 11. Block 37, RIVER PARK — Lot 70, Block J9
UNIT 4, according to the Plot FIR to N18'30100 E 180.00'
thereof, as recorded in Plat Book -
11, Pages 9, Public Records of PVC m
St. Lucie County, Florida. wdlON2o Pact cane Pooi „ `- - -2s.e'----
I.
4'Motel Fence .�;>,;lEqu+pmentCA, q 32.5 t
LP Tank
SURVEYOR'S REPORT o 1 435' " C s 0--31c
1 This Survey shall not be valid unless sealed v$ I
with an i ry o c
embossed Surveyors Sea!
2 No underground improvements have been
located 09 O = j O'4• 356
port of this Survey. q I Concrete :y4 a ° a P m
3 The lost veld date of this Survey was ;, g Pool Deck. a o a
4 This 1 Survey was prepared using the Plot of rn 3 i tot 11, Block 39 4.0' ;� c
0 onerote?Wal` One Story Resldence n
Record only. t -13.6' o m t E
+• ,.•i 139 N. Naranjo Ave. 10 CAE r ,
No other documents were provided and no 3 a
search of the public records was 2 's I Concrote $
performed by this office. ai 4.4' Dnvaway uil
5 This Survey was prepared In accordance with
-- ------77,1'-- --�_---- -- 5.9' t F {}
the stnards for the practice of Surveying& -"- i Ccv a Conc.
Mopprng as defined in 5J-iZ050-052FAC. i one ? ^
6 By acceptance of this survey all parties agree 4'Metal fence a03 ` {{
that the signing surveyor's liability Is limited to t-10.4' --- -----41,2-------- rt. �.
the amount paid for said Survey. I cone, I {{ 1
7 Unless other wise noted all bearing and
distances are in accordance with the record plat nI
and have been verified by field measurements. b N Port SaintTc a` -I-
See map for bearing base. 6' Fence Sewer Monl�ple
Wyod �- pp _ F�7
8 Parcel/Lot line locations have been based on p 5' Choir_ ' Fenca
found survey control along the center and/or Lot
right of way line of N Naranjo Ave. — j- J.51' 18
9 Left Blank { Lot 12, Block 39E 180.00
10 The Legal Description shown hereon was
provided by the client and/or his/her rood Zone Data derived by such
I methods of the orfkol FEbW Maps and
representatives. limited to the accand AE of such mope.
P Fk+od Zone:X and AE with Base Flood Elevation 6 Canmudity j: 120285, w
11 No ownership of fence lines has been LEGEND rat-Fame 41.4Ya¢r t.Manwsmt Panel j:0281E ^I
determined as part of this Survey, c-_ca+ads nP-ra d i'to F,p. sutra:a,Dote:Z18.2012 I
12 Off set calls to found surveycontrol ore C/E 0'"ted Entry FM Fama�w.A0•7n COP a
Ca mo Poe w7h AV Cad.Pon V Fa-F..V svn Rae W
relative to the nearest property comer, ce-eaten an . g
ess-ea.er�Se ew,ex St.au a F=-r r4 0 Ir-Rae.an Cap PREPARED FOR,
intersection of lines, point of curvatures (PC), aW-CWr.;ded mdal Pqx sac-sat 15/W Roe.ah cw 1e/ruY -I
cat-cmcr. Pea n h Pool Eww+�+e ncc-roma 112 kon Pipe-a cv ' Robert C Adams and Denise Patricia Adams
point of 'reverse curvatures (PRC) or other cry_c:u.ry&. 1u-rawa7�q ua
identifiable Dint ry-Warr roe vehe nm-ra.d rr•9 waa.rtn ff.,r Branch Banking and Trust Company, its successors and or pRC n
P in-Fm tq=m ni-rbuM Nei =
13 Compliance with local zoning requirements oR-aahe.d UW4 u.. nm-Poud Naa Wh n.Fab assigns, as their Interrest may appear Mitchell
and or with requirements set forth by other PP-Pr,pow WX-rcwd PX hWsoar-5a.a.7 saw Nam* nWD-Famd PK W-M diet+ Christopher J. Twohey, P.A. Mitchell
State, Public; and/or Private entilies has not w=ray�`°"'"""`ccu" a. n?ICO��.�caoa a°i" Old Republic Notional Title Insurance Company
been verified as port of this Survey, i1v-water Mma aAcancan EhQdma
Prepared By: Regina C. Kamer, PSM#4363
Kamer Surve in Inc. LB 7357
ar.+nu.,
Prepared For: KARNER SURVEYING, INC. *= er �'"="�°" —' �Boandory Survey
Residential & Commercial Surveying Services
Robert C & Denise P Adams
2740 S °v"°j=aroma°=isse-rn "'�
R Martin Downs Blvd.,g333 �`` ��;
Palm City, Florida 34990 tto
St. Lucie Count Florid PHONE: 1-772-288 7208 FAX: 1-772-223 8181o.w►ir."u proj: SLC_RiverPork/RivPark4-37-O96S,
IYk