Loading...
HomeMy WebLinkAbout30x60 Life Safety PlanU TYPICAL DOOR FRAMING HEADER STRAP i— EQUAL TO HUGHES HLSTA 24 (1260# UPLIFT) swm - X O 16 4 O.C. STUD HURRICANE ANCHOR EQUAL (1250# UPLIFT) TYPICAL FRAMING SCALE: 3/8" = P-O" III MAX � vlhqh \ ( -LX4 111f2 2 -2X4 SYPf2 2 -2X4 SYPf2 O f6' O.C. TYPICAL WINDOW FRAMING FLOOR PLAN SCALE: 1 /4" = F-0" LAV LAV SUPPLY LINE IS BASED ON AN ASSUMED AVAILABLE PRESSURE OF 46 TO 60 PSI AT MAIN INLET. ALL STUB -UPS 1/2' SUPPLY COLUMN STRAPPING SCHEDULE A INDICATES TYPE OF STUD TI INDICATES TYPE OF TIE DOWN STRAP INDICATES WITH RIDGE BEAM BEARING ■ STIFFENER ( SEE RIDGE BEAM NOTES FOR SPECIFICATIONS) COLUMN STRAPPING SCHEDULE 0(2) 2x4 SPF #2 THIS HALF O(2) 2x4 SPF #2 EACH HALF 0(3) 2x4 SPF #2 THIS HALF &3) 2x4 SPF #2 EACH HALF 0(4) 2x4 SPF #2 THIS HALF F&4) 2x4 SPF #2 EACH HALF (0, (5) 2x4 SPF #2 THIS HALF D(5> 2x4 SPF #2 EACH HALF (6> 2x4 SPF #2 THIS HALF 0(6> 2x4 SPF #2 EACH HALF 0(7) 2x4 SPF #2 THIS HALF L&7) 2x4 SPF #2 EACH HALF M (8) 2x4 SPF #2 THIS HALF N&8) 2x4 SPF #2 EACH HALF NOTES - I, ALL COLUMN STUDS SHALL BE NAILED TOGETHER PER NDS AND FASTENED TOGETHER WITH 100% PVA GLUE COVERAGE. 2. COLUMN STUDS SHALL NOT BE NOTCHED OR BORED. 3. INSTALL ONE TIE DOWN STRAP FROM RIDGE BEAM TO COLUMN AND FROM COLUMN TO FLOOR RIM JOIST FOR EACH STUD OF COLUMNS. (le- 3 STUD COLUMN WILL REQUIRE 4 TIE DOWN STRAPS) 4. STRAPS SHALL NOT BE OVERLAPPED OR DOUBLED UNLESS SPECIFIE OTHERWISE. TIE DOWN STRAP DESCRIPTION TI 20 GA. X I - 1/2' GALV. STEEL STRAP WITH (7) 0.148'OX3' NAILS EACH END. TWO 26 GA. X 1.5' GALV. STEEL STRAPS MAY BE SUBSTITUTED FOR ONE 20 GA. X I - 1/2' STRAP. NAILS MUST PENETRATE 2' MININUM INTO ALL MEMBERS. PENETRATION MAY BE REDUCED TO I - 1/2' IF 8 NAILS ARE USED IN LIEU OF 7. IN NO CASE SHALL SPLITTING OF WOOD BE PERMITTED. 2' VTR 1 SINK 3, INSTALL e FACTORY 3' 3' TO WASTE 3' TO WASTE 3' TO WASTE TERMINAL TERMINAL TERMINAL AALLLL SINK 6 LAV'S PROVIDEED WITH 1 1/2' TRAPS WITH SLIP JOINT CONNECTIONS. DWV PLUMBING RISER SCALE: 3/8" = F-0" e " NOTICE " THESE DOCUMENTS WILL NO LONGER BE VALID 21 DAYS AFTER THE DATE SIGNED VALID THIRD: JULY 14TH, 2020 IY O LL LNU of o D D co V °E�sEP°so= Julio Orbegoso J - No.38769 / ) 1 co 2020.06.23 V/ J ! �� STATE of TF OP 16:11:08-04'00' Q �'s`SfONAL J THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY JULIO ORBEGOSO, P.E. ON THE DATE AND/OR TIME STAMP SHOWN USING A 0 DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENTARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURES MUST BE O VERIFIED ON ANY ELECTRONIC COPIES. CONSULTING ENGINEER JULIO ORBEGOSO 202 DORIS DR. LAKELAND, FL 33813 PE LICENSE #38769 REVISION DATE: DATE: 05-20-2O19 DRAWN: R.L.G. JOB #. CPX-114722 0 SHEET NO. Al