Loading...
HomeMy WebLinkAboutPermit Revision Form 7.28.20EXHIBIT “A” – Detailed Description of Project Revisions Permit 2002-0417 • Women's restroom renovations removed from scope of work (existing restroom to remain, we are only updating finishes at this time). • Men's existing restroom layout revised to match existing conditions; new layout has been modified. • One unisex restroom has been added to the scope of work. • Emergency lighting added to men's and unisex restroom per code. • One 35' sidewalk added to concrete scope. • Concrete ramp at front of the building has been modified. ADA ramp has been reconfigured to accommodate handicap spaces accordingly. F9 F1 NE W D O O R 6'-0" 8' - 4 " 8'-012" 11 ' - 8 1 2 " 7' - 0 " 14'-418" FLOOR DRAIN TO REPAIR DRYWALL PARTITIONF4 F7 30"30" 5' - 0 " E- LIGHT E- LIGHT 8' - 4 3 4 " 36"36" UNISEX 8'-1" NEW EXHAUST FAN NE W D O O R LVQD1 LVQD2 E01 30"30" E- LIGHT E- LIGHT 8'-1" 8' - 4 3 4 " 36"36" 5' - 0 " UNISEX R-13 BATT INSULATION. 5/8" GYP. BD. TP X TWO SIDES W/ 1 1/2" LONG SELF DRILLING SCREWS @ 4" O.C. EDGES AND 12" O.C. FIELD. JOINT COMPOUND TO BE VINYL, DRY OR PRE MIXED APPLIED IN TWO COATS TO JOINTS AND SCREWS. PAPER TAPE TO BE 2" WIDE EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS. ATTACH BOTTOM TRAC TO SLAB WITH 'HILTI' OR EQ. 7/32"Ø POWER DRIVEN ANCHORS @ 16" O.C. ( W/ 17/32" EMBED. FASTEN TRAC TO VERTICAL STUD W/ SHEET METAL SCREWS @ 24" OC EACH SIDE. EXISTING CONC. SLAB 18 GA. MTL. STUDS @16" OC MAX ACOUSTICAL CEILING TILE (SEE RCP) BASE ROOFING TOP TRAC JOINED TO GRID WITH #8 PAN HEAD ZIP SCREWS 12' OC HO S A N N A B U I L D I N G C O N T R A C T O R S 27 8 S E M O R A N C O M M E R C E P L A C E AP O P K A 3 2 7 0 3 40 7 . 4 8 2 . 8 3 3 2 A1 COCA-COLA Ft. Pierce ADA Restroom Renovation BUILDING CODE REFERENCE FLORIDA BUILDING CODE- 2O17 6th Edition INFORMATION ON DRAWINGS SECTION 1606.1.7 FBC SECTION 1606 1.BASIC WIND SPEED FLORIDA 170 MPH- 3 SECOND GUST 2.WIND IMPORTANCE FACTOR 11 BUSINESS OCCUPANCY 3.WIND EXPOSURE FLORIDA WIND EXPOSURE B 4.INTERNAL PRESSURE COEFFICIENT BUILDING SIMPLE DIAPHRAGM MEETING THE 7 SHAPE CRITERIA 5.COMPONENTS & CLADDING INTERNAL PRESSURE COEFFICIENT= 0.18 DESIGN WIND PRESSURE 32 PSF FOR COMPONENTS CLADDING DESIGN WIND PRESSURE FOR OPENINGS: +29.4 PSF / -34.7 PSF FOR 36" WIDTH OPENING STREET ADDRESS 3939 ST LUCIE BLV. FORT PIERCE, FL 34946 PARCEL NUMBER 1432-222-0001-000-9 PARCEL ZONING INDUSTRIAL JURISDICTION: CITY of FORT PIERCE, ST LUCIE COUNTRY, FLORIDA PROJECT DESCRIPTION: INTERIOR DEMOLITION of EXISTING, NEW TENANT IMPROVEMENTS BUILDING OCCUPANCY GROUP 41 MANUFACTURING PARCEL DESCRIPTION COCA-COLA PLAT 162-21 B PARCEL A ADOPTED CODES FLORIDA BUILDING CODE- 2017 6th Edition CODE INFORMATION BUILDING: FLORIDA BUILDING CODE- 2017, EXISTING BUILDING FIRE: FLORIDA PREVENTION CODE- 2017 PLUMBING: FLORIDA BUILDING CODE, PLUMBING- 2017 MECHANICAL: FLORIDA BUILDING CODE, MECHANICAL- 2017 ELECTRICAL: NATIONAL ELECTRIC CODE, 2014 ENERGY : FBC 2017 ENERGY EFFICIENCY FOR BLDG CONSTRUCTION ACCESSIBILITY : 2017 FLORIDA ACCESSIBILITY CODE FOR BLDG CONSTRUCTION NORTH F1 - Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the face of the door, measured perpendicular to the face of the door or gate. ( 3068 solid core birch door) F2 - ADA ground and floor surfaces along accessible routes must be stable, firm and slip-resistant F3 - One piece plated stainless steel WashBar includes touch-free soap, water and hand dryer - ADA COMPLY Specification: Verge with washbar - LVQ-Series ( LVQD1) F4 -Waterless Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (430 mm) maximum above the finish floor or ground. Urinals shall be 13 1/2 inches (345 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture. F5 -The sink high forward reach shall be 48 inches (1220 mm) maximum where the reach depth is 20 inches (510 mm) maximum. Where the reach depth exceeds 20 inches (510 mm), the high forward reach shall be 44 inches (1120 mm) maximum and the reach depth shall be 25 inches (635 mm) maximum. F6 -The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 F7 -The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. F8 -Rab Bars. Grab bars for water closets shall comply with 609. Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. F9 -Pictograms shall have a field height of 6 inches (150 mm) minimum. Characters and braille shall not be located in the pictogram field. F10 -ADA mirror on each sink F3.1 - One piece plated stainless steel WashBar includes touch-free soap, water and hand dryer - ADA COMPLY Specification: Verge with washbar - LVQ-Series ( LVQD2) E1 -ELECTRICAL OUTLETS FOR THE SINK SYSTEM FINISH PLAN KEY NOTES ELECTRICAL PLAN KEY NOTES 3/8" = 1' MEN'S RESTROOM2 EXISTING BUILDING SITE PLAN 3/8" = 1' NON RATED WALL1 Gr e g o r y D . G a i n e r , P . E . FL P E 7 0 8 8 5 53 8 7 A l h a m b r a W a y S o u t h St . P e t e r b u r g , F L 3 3 7 1 2 CO C A - C O L A F T . P I E R C E 39 3 9 S T L U C I E B L V . F O R T P I E R C E , F L 3 4 9 4 6 ELECTRICAL 3/8" = 1' DATE: 07/21/2020 EXISTING EXHAUST FAN TO REMAIN Gr e g o r y D . G a i n e r , P . E . FL P E 7 0 8 8 5 53 8 7 A l h a m b r a W a y S o u t h St . P e t e r b u r g , F L 3 3 7 1 2 HO S A N N A B U I L D I N G C O N T R A C T O R S 27 8 S E M O R A N C O M M E R C E P L A C E AP O P K A 3 2 7 0 3 40 7 . 4 8 2 . 8 3 3 2 A2 CO C A - C O L A F T . P I E R C E 39 3 9 S T L U C I E B L V . F O R T P I E R C E , F L 3 4 9 4 6 3/4" = 1'-0" EXISTING MEN FLOOR PLAN1 DATE: 07/21/2020 NEW SIDEWALK 20'x5' CURB CUT CURB CUT EXISTING BUILDING DELIVERY RAMP ONLY SIDEWALK TYP. 5' WIDE 5'x5' LEVEL LANDING GR A S S HE D G E S GRASS AREA GR A S S 5'x5' LEVEL LANDING LEVEL W/ ASPHALT 35 ' - 0 " ADA RAMP GLASS GLASS DOOR 6"RAMP TO EDGE BLDG Gr e g o r y D . G a i n e r , P . E . FL P E 7 0 8 8 5 53 8 7 A l h a m b r a W a y S o u t h St . P e t e r b u r g , F L 3 3 7 1 2 HO S A N N A B U I L D I N G C O N T R A C T O R S 27 8 S E M O R A N C O M M E R C E P L A C E AP O P K A 3 2 7 0 3 40 7 . 4 8 2 . 8 3 3 2 3/16" = 1' FLOOR PLAN1 1/2" = 1' RAMP ELEVATION2 S1 CO C A - C O L A F T . P I E R C E 39 3 9 S T L U C I E B L V . F O R T P I E R C E , F L 3 4 9 4 6 DATE: 07/21/2020 DELIVERY RAMP ONLY SIDEWALK TYP. 5' WIDE TRUCK PARKING STOP BUILDING 2 BUILDING 1 VISITOR'S PARKING LOT RAMP PROPOSED WORK AREA IN AND OUT ACCESS Gr e g o r y D . G a i n e r , P . E . FL P E 7 0 8 8 5 53 8 7 A l h a m b r a W a y S o u t h St . P e t e r b u r g , F L 3 3 7 1 2 HO S A N N A B U I L D I N G C O N T R A C T O R S 27 8 S E M O R A N C O M M E R C E P L A C E AP O P K A 3 2 7 0 3 40 7 . 4 8 2 . 8 3 3 2 1/32" = 1'1 SITE PLAN - AREA OF WORK S2 CO C A - C O L A F T . P I E R C E 39 3 9 S T L U C I E B L V . F O R T P I E R C E , F L 3 4 9 4 6 DATE: 07/21/2020 OFFICE USE ONLY: DATE FILED: _____________________________ PERMIT # _______________________________ REVISION FEE: ___________________________ RECEIPT # ______________________________ ______________________________________________________________________________________________ PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: ___________________________________________________________________________________ ___________________________________________________________________________________ DETAILED DESCRIPTION OF PROJECT REVISIONS: ___________________________________________________________________________________ ___________________________________________________________________________________ CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ______________________ ST. LUCIE CO CERT. #: ____________ BUSINESS NAME: _________________________________________________________________ QUALIFIERS NAME: ________________________________________________________________ ADDRESS: _______________________________________________________________________ CITY: _______________________ STATE: _______________ ZIP: _______________________ PHONE (DAYTIME): ________________________ FAX: _____________________________ OWNER/BUILDER INFORMATION: NAME: ____________________________________________________________________________ ADDRESS:__________________________________________________________________________ CITY: _____________________________ STATE: __________ ZIP: __________________ PHONE (DAYTIME: ___________________________ FAX: _____________________________ ARCHITECT/ENGINEER INFORMATION: NAME: ____________________________________________________________________________ ADDRESS: _________________________________________________________________________ CITY: _____________________________ STATE: ____________ ZIP: ___________________ PHONE (DAYTIME): ___________________________ FAX: ____________________________ SLCCC: 9/23/09 Revised 06/30/17