HomeMy WebLinkAboutDrawing, layoutDifrancesco Construction, Inc.CourseBeam with (1) #5 RebarFilled with Grout eachTwo Course PerimeterEnergy CodeBoardover 3/4" Insul.1'-6"Trusses under LathLayer of #15 Felt onTrusses, Provide (1)Lath Fastened toTypical Wall SectionTreated FillCompacted, TermiteVisquine on Clean,on .0064" 3000# Fibermix conc.Varies0.00'6"6122'-0"T.O.B.F.F.E.4"Concrete Block.Stucco Finish overCMU Typ.8 x 16 x 8 GradeRebar In CellsLap. Tie to Vert.10" Hook and 30"#5 Vert. Rebar with30" Lap for LocationsSee Floor Plangrout filled cell#5 vert. rebar in1/2" d.w.strips 24"o.c.1 x 2 p.t. furringFirestop1 x 4 p.t.1/2" d.w.High Ribbed WireStucco Soffit overPine Fascia2 x 8 R.S.Insulation perSpray FoamOthersShop Drawings byRoof Trusses 24"o.c.Pre Engineered WoodScheduleSee Connectorper nailing schedulec.d.x. plywood fastened asunderlayment on 19/32"over "Peel and Stick"Metal Roofing Panelsover 1 x 2 p.t.Galv. Drip EdgeIcynene18" x 16" 3000# Cont.Conc. Mono. Footing with(2) #5 rebars cont.1'-0"
4"Min.F.F.E.F-12011 National Electrical Code: NFPA 70Single Family residenceStructure Designed: Enclosed2017 Florida Building Code: ResidentialNew One level CBSBuilding CodeScope of WorkProject DataProject Name: Rosen ResidenceStreet Address: XXXX Laurels PlaceCity: Port St. LucieCounty: St. LucieState: FloridaSoil bearing capacity: 2000 p.s.f.Internal Pressure Coefficent: .18Wind Exposure: BDesign LoadsRoof Live Load: 20.0 p.s.f.Wind Speed: 160 MPHWind Importance Factor: 1.0Building Category: IIProject Area: 5.223 s.f.Number of Stories: OneConstruction Type: VOccupancy Type: Group RBuilding DataInsulation Smoke Developed Index: Not to exceed 450Ceiling Finishes: Not greater than 200Wall Finishes: Not greater than 200Insulation Flame Spread: Not to exceed 25 Flame Spread Index & Smoke Developed IndexTermite Area: Very HeavyClimatic & Geographic Design CriteriaWeathering: NegligibleA L L E N & K I M R O S E NA-1daterevisionsheetjob numberscaledatecheckeddrawn1089Aas noted1/21/18s.l.s.l.Steve LiCausi Design Group, Inc.
R E S I D E N T I A L D E S I G N E R S
4240 Gator Trace Ave. Unit A, Ft. Pierce, FL, 34982
Office: (772) 785-6465
C U S T O M R E S I D E N C E B Y :Subdivision: P.G.A. Villagescale: 3/16" = 1'-0"Floor Plan9060 H.R.Egress14s.h.(2) 28" x 28"Fixed GlassSafety Glass(2) H36 s.h.with 24" TallFixed GlassTransomsTransomsFixed Glasswith 24" Tall(2) H36 s.h.60100Arch Top16080 Overhead10080 Overhead(2) H36s.h.3080 26 s.h.Egress26 s.h.Egress26 s.h.Egress9060 H.R.Egress2880
French
French30809080S.G.D.6080S.G.D.4'-6"4'-2"160100PocketS.G.D.16'-2"2'-2"5'-6"2'-2"a.h.Pool EquipmwntLocationL.L.a.h.PantryGarageFrzr.Ref.Softnr.WaterLnd.a.h.Bdrm. 3ClosetClosetL.KitchenSummerBarWetCigar RoomPorchBdrm. 4ClosetPorchDiningKitchenClosetGarageMaster Bdrm.Living RoomGreat RoomLiving 3621Porch 538Area TabulationGarage 975Entry 89Total 5223 s.f.Bdrm. 2W.H withRecerc. PumpPoolDeskAttic Access
with Ladder
with Ladder
Attic Access 18'-0"49'-4"1'-4"12"2'-4"19'-4"14'-8"2'-0"34'-5"14'-11"19'-8"8"6'-8 1/2"5"5'-2"5"2'-4"8"8'-4"4'-3 1/2"10'-4"8"8"22'-0 1/2"3'-0"13'-11 1/2"18'-0"19'-8"8'-8"1'-4"12"4'-5"10'-0"3'-0 1/2"2'-7"12"12"3'-0"5'-7 1/2"8"8"16'-0"2'-8"7'-8"2'-4"2'-0"10'-0"2'-8"1'-4"2'-6"11'-10"4'-0"2'-7"2'-4"6'-2"12"2'-8"2'-0"6'-0"7'-4"4'-8"5'-5"7'-10 1/2"3'-0"2'-6"12'-0"2'-11"2'-7"1'-11"2'-6"5'-7"3'-6"3'-7"3'-7"6"4'-5 1/2"21'-4"16'-4"108'-0"64'-4"43'-8"3'-11"23'-7"27'-3"9'-7"6'-0"37'-8"74'-8"
24'-0"
14'-8"6'-8"2'-8"
7'-4"7'-4"
35'-0"15'-8"
8"2'-0"8"
8"13'-2"8"13'-7"8'-0"13'-5"3'-0"8'-8"4'-0"
5'-9 1/2"5'-9 1/2"2'-0"4'-0"4'-0"2'-0"5'-8 1/2"5'-8 1/2"4'-4"4'-4"
8"10'-7"3'-8"2'-4"1'-4"2'-4"13'-0"8'-8"9'-10"2'-3"14"12"3'-8"3'-8"3'-8"8"12"14"
2'-3"3'-1"3'-0"3'-4"3'-8"1'-8"12"22'-0"6'-6"3'-8"5'-10"8"
3'-0"
8"9'-0"1'-8"1'-4"2'-0"
2'-3"
10'-2"3'-6"8"2'-3"3'-0"
8"3'-3"4'-9"8"
15'-8"
8"16'-0"8"
33'-0"39'-4"
17'-0"16'-0"22'-0"17'-4"
8'-6"8'-6"4'-0"1'-4"10'-8"
6'-0"4'-8"
2'-0"16'-0"4'-0"8'-8"8'-8"Cantilever Trusses6'-10"2'-8"11'-4" Clng. & !2" Coffer11'-4"Clng.Clng.11'-4"11'-4"Clng.11'-4" Clng.11'-4" Clng.14'-0" Clng.14'-0" Clng. & !2" Coffer14'-0" Clng.& 12" Coffer11'-4" Clng.11'-4" Clng.11'-4" Clng.from F.F.E.14'-0" Clng.11'-4"Clng.11'-4" Ceilingfrom F.F.E.from F.F.E.11'-4" Ceiling10'-0" Clng. & !2" Coffer10'-0"Clng.10'-0" Ceiling10'-0" Ceiling10'-0Clng.10'-0" Ceilingfrom F.F.E.10'-0" Ceilingfrom F.F.E.PDF created with pdfFactory trial version www.pdffactory.com
ONE UNIT TO BE REMOVED AND
REPLACED/WARRANTY REPLACEMENT