Loading...
HomeMy WebLinkAboutProduct approvals, FL251_R32_II_19-1126.03M IAM I-DADE MIAMI-DADE COUNTY • PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy PGT Industries, Inc. 1070 Technology Drive, North Venice, Fl. 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the Hiah Velocitv Hurricane Zone. DESCRIPTION: Series "SGD-770" Aluminum Sliding Glass Doors w/ 900 & 1350 corners —L.M.I APPROVAL DOCUMENT: Drawing No. PGTO130 Rev C, titled "Series 770 Alum. SGD - LM Impact', sheets 1 through 22 of 22, dated 10/10/14 and last revised on 11/22/19, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. Max eight (8) panels configuration unit is allowed, having max nominal panel size not to exceed tested height & width per tables 1 thru 3. See sheets 6, 7 and 8 for Design Pressures (DP), glass types, Sill type for Positive DP limits, applicable Standard or Heavy Duty parts and anchorage requirements. See Typ. Installation in sheet 10 for straight configured units, sheet 11 for corner units and sheet 14 for pocketed units. Pockets & Egress requirements to be reviewed by Building official. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 17-0420.12 and consists of this page 1 and evidence pages E-1, E-2 & E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq L Chanda, P.E. NOA No. 19-1126.03 MIAMI DADE COUNTY Expiration Date: February 17, 2025 Approval Date: January 09, 2020 Page 1 PGT Ind ustriea_ Ivc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitt¢d under previous approvals under Til¢ #15-101315 A. DRAWINGS 1. Manufacturer's die drawings and sections (submitted under files See below) 2_ Drawing No. PGT0130, titled "Series 770 Alum. SGD — LM Impact", sheets 1 through 22 of 22, dated 1 O!1 O/14, with revision A dated 1 O/OS/15, prepazed by manufacturer, signed and sealed by Lynn Miller, P.E_ B_ TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-7554, dated 11/Ol/13, signed and sealed by Marlin D_ Brinson, P_E.(Submitred under NOA No_ 74-OI23.I0) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FSC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 � Forced Entry Test, per FBC 24113.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum sliding glass door, prepazed by Fenestration Testing Laboratory, Inc., Test Reports No.: FTL-5980-A, FTL-6001-R and FTL-6015-R, which have been revised and reissued on 12/29/09, all signed and sealed by Julio Gonzales, P.E.(Subxtftled under NOA No_ 09-0826_IO) Along wish marked -up drawings and installation diagram of an aluminum sliding glass door, prepared by Fenestration Testing Laboratory, Inc., Test Reports No._ FTL-59S0, FTL-5993, FTL- 6036, FTL-6001, FTL-6014, FTL-6015, FTL-6017, FTL-6023, FTL-6024, FTL-6025, FTL-6028, FTL-6031, FTL-6033 and FTL-6036, all dated 08/30/09 and signed and sealed by Julio Gonzales, P.E. (Subntiaed under NOA No. 09-0826.IOf 3. Additional, Reference Fixed window test report FTL-7897 (cazdinal spacer) per TAS 201, 202 � 203-94, issued by Fenestration Testing lab (Test report submitted under file #15-0430.08) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-5"' Edition (2014), dated Ol/30/15, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2_ Glazing complies with ASTM EI300-04 D. QUALTTY ASSURANCE 1_ Miami -Dade Department of Regulatory and Economic Resources (R F..R). 1st+--� 1- CG-�-L- lahaq I. Chavda, P_E. Product Covtrol IIvit Sup¢rvisor NOA No_ 19-1126.113 Expiration Date: February 17, 2025 Approval Date: Sanuary OR 202a E-1 PGT Industries. Ivc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1, Notice of Acceptance No_ 14-0916.10 issued to Kuraray America, Inc_ for their `Butacite® PVB Glass Interlayer" dated 04/25/15, expiting on 12/11/16_ 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and Wbite) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. F_ STATEMENTS 1. Statement letter of conformance, complying with FBC-5`^ Edition (2014), dated October 8, 2015, issued by manufacturer, signed and sealed by Anthony Lynn Millet,. P.E. G. OTHERS 1. Notice of Acceptance No. 14-0128_l 1, issued to PGT Industries, Inc. For their Series "SGD-770" Aluminum Sliding Glass Doors w/90� &c735^ corners -L.M.I. expiring on 02/1720_ 2. Evidence submitted under previous approvals under t'ile #16-2609_D6 A. DRAWINGS 1. Drawing No. PGT0130, titled "Series 770 Alum_ SGD — LM Impact", sheets 1 through 22 of 22, dated 10/10/14, with revision B dated OS/OS/16, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P_E. B. TESTS 1. Reference Test report on 1) Uniform Static Air Pressure Test, per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with marked -up drawings and installation diagram of Aluminum Sliding Glass Doors (w/ PS, Super, Cardinal 8c Duraseal Spacers), prepared by Fenestration Testing Laboratory, Inc., Test Reports No(s) FTL-8717, FTL-8970 and FTL-8968, dated 02/15/16, 06/07/16 and 06/20/16, all signed a4c sealed by Idalmis Ortega, P_E_ C_ CALCULATIONS (Submitted under previous NOA) 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of conformance, complying with FBC-5`* Edition (2014), dated October 8, 2015, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Test proposal No. 16-0152 dated 03/09/16 approved by RER. G. OTHERS 1_ Notice of Acceptance No. 15-1013.15, issued to PGT Industries, Inc. for ibeir Series "SGD-77D" Aluminum Sliding Glass Doors w/90' 8c135� corners - L_M.L, expiring on 02/17/2D. \St..� � . LI,.....�- Iahaq I. Chanda, P.E. Product Control Uni[ Supervisor NOA No. 19-1126.03 Expiration Date: February 17, 2a25 Approval Date: January 09, 2020 E-2 PGT Industries. Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. Evidence submitted under previous approvals under frle #17-042012 A. DRAWINGS 1. Drawing No. PGT013Q titled "Series 770 Alum. SGD — LM Impact", sheets 1 thrcugh 22 of 22, dated 30/30/14, with revision C dated 04/OS/17, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-6t° Edition (1017), dated 04/18/17 and revised on OS/30/17, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Glazing complies with ASTM EI300-09 D_ QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Ecoaoaaic Resources (RER). E_ MATERIAL. CERTIFICATIONS I. Notice of Acceptance No. 16-1117.01 issued to Knraray America, Inc_ for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated Ol/19/17, expiring on 07/OS/19. F_ STATEMENTS 3. Statement letter of conformance with FBC-6'� Edition (2017), dated 08/30/37, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. G. OTHERS 1. Notice of Acceptance No. 16-0629.06, issued to PGT Industries, Inc. for their Series "SGD-770" Aluminum Sliding Glass Doors w/90� 8c135� comers - L.M.L, expiring on 02/17/20_ 4. New Evidence submiH¢d A. DRAWINGS 1. Drawing No. PGT012S Rev C, titled "Series 670 Alum SGD-Non-Impact", sheets 1 through 22 of22, prepared by manufacturer, dated 02-02-14 and last revised on 11/22/19,. signed and sealed by Lynn Miller, P.E. C. CALCULATIONS (submitted under Sle #17-0420_72) ]. None D. QUALITY ASSURANCE I. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305A2 issued to Knraray America, Inc. for (heir "Trosifol® Ultrscl¢aq Clear and Color PVB Glass Interlayers", expiring on 07/08/24. 2. Notice o{Acceptance No. 17-OSOS.02 issued to Kuraray America, Inc_ for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/23. F. STATEMENTS 1. Statement letter of conformance to FBC 2017 (6°i Edition) and letter of no financial interest, prepared by PGT, dated 7 122/19, signed and sealed by Lynn Miller, P.E. G. OTI-IER I. This NOA renews NOA # 17-042012, expiring April 07, 2025. Is�G. \ `�� `..�_ Lhaq L Chanda, P_E. Product Control Unit Supervisor NOA No. 19-1126.03 Expiration Data: February 19, 2025 Approval Date. January 09, 2D20 E-3