Loading...
HomeMy WebLinkAboutPermit WorksheetsA PERMIT NUMBER e Installer -e: Z-1�,4r�_ License Addressofhoms 7TA being Installed Manufacturer 4/'? S Length xwidth 7 �7 NOTE • if home Is a single wide fill out one hall of the biocklag plan If home [so triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on any home (new or used) More the sidewall ties exceed 5 ft 4 in. Installer's initials PERMIT WORKSHEET New Home . Q Used Home �- Page 1 of 2 Home Installed to the Manufacturer's Installation Manual ❑ Home is Installed in accordance with Rule 16•0 Single wide ❑ Wind Zone II Wind Zone III ❑ Double wide � Installation Decal TriplelOuad ❑ Serial eole J dOL PIER SPACING TABLE FOR USED HOMES Load Footer bearing size 166x16' IS I&x t8112' 201x20' 22'x22+ 24'XZ4' 26'%26' capwlty (sq In) (266 2 (400) (464)• (576)' (b76) 100 e 9 00 6 6 16 00 a 6 s 2 00 s 6 8 6 g s000 s 0 psi I e. 6 - PIER PAD SIZES I-beam pier pad size 12 Perimeter pier pad size /% �� X 2 2 r r Other pier pad sizes _ 7, r� x;? 2 rr • (required by the mfg.) MIDraw the approximate locations of marriage wall openings 4 toot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and .their pier pad sizes below. POP AR PAD SIZES ANCHORB 4 it FRAME TIES within 2' of end of home spaced at 5' 44 oo OTHER TIES LongRudlnal Sfablllzing Device (LSD Sidewall N ben Manufacturer We, Longitudinal Longitudinal StabillzingDevlce w/Larera/Arprs Marriage wall Manufaelurer 1n. u O. i F Opening Pier pad:size ri %f �1 of TIEDOWN COMPONENTS PERMIT WORKSHEET I Page 2of 2 PERMIT NUMBER `.....::::...:., POCKET PENETROMETER TES Thepbcket penetrometer tests are rounded �'to pat or check here -to declare 1000 lb. soil _f` without testing. X_ X_ X_ POCKET PENETROMETER TESTING METHOD i. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the footers S. Using 500 Ib. increments, take the lowest reading end round down to that increment. X X__ TORQ E. PROBE TEST - -. The results of the torque probe test Is :2 N '� Inch pounds or check here If you are declaring 5' anchors without testing - A test showing 275 inch pounds or less will require 5 foot anchors, Note: A state approved lateral arm system is being used and 4 It anchors are allowed atihe sidewall locations. 1 understand 5 it anchors are required at all centerline tie pointp where the torque test reading Is 275 or less and where the mobile home manufacturer may requires anchors with 4000 .ding capacity. Installer's Initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER //< ` Installer Name e %`•e• _�� e �p 1 ?14 Date Tested Fre�ulpal Ibnnect electrical conductors between multi -wide units, but not to the main power Durce. This-ingludes the bonding wire between mutt -wide units. Pg, - Plumb no lity, onnect all sewer drains to an existing sewer tap or septic tank Pp. onnect all potable water supply plPing to an existing water meter, water tap, or other idependent water supply systems. Pg. Site Preparation - Debris and organic material removed Water drainage: Natural _Swaie Pad Other Fastenlno mull' wide units Floor. Type Fastener Len rr Length: �a Spacing: 2 n Walls: Type Fastener. Length: � Spacing: J s •' Roof: Type Fastener, Length: �_ Spacing: t1 For.used homes asnin. 30 gauge, S' wide, galvanized metal strip will be centered "over the peak of theroof and fastened with galy, roofing nails at 20 on center on both sides of lha centerline. Gasket lwmlhemr fl ar.a I n I understand a property Installed gasket Is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly Installed or no gasket being installed, I understand a strip of tape will not serve as a gasket. Installer's initials Type gasket "4 _Installed: Pg. Between Floors Yes Between Walls Yes Bottom of of ridnebeam Yes r-- Wmtherprootlnn The bottomboard will be repaired and/or taped. Yes `' pp, Siding on units is installed to manufacturer's specifications. Yes Fireplace chimney Installed so as not to allow intrusion of rain water. Yes &/01 Mlaeellnnecus Skirting to be Installed Yes ---,?To Dryer vent Installed outside R skirting. Yes • � NIA Range downflow vent installed -outside of skirting. Yes WA A Drain lines supported at 4 foot intervals, Yes 4i Electrical crossovers protected. Yes Other: Is accurate and true based -on the Installer Signature Dat�1-/.1 -�ULG