HomeMy WebLinkAboutEngineering ST�
_ 500 SW 12th Ave
-- Deeffield Beach,FL 33442
WI
� t� UV
Ph.561-922-6747
Fax.561-292-3562
Property Information Building Information
Owner: t)wul to 1{,MCELANEY Wind Zone: 170 MPH.
Address: 288 OLD KEY WEST PL Exposure Category: C
FORT PEIRCE,FL 34982 Minimum Building Dimension: 41 ft.
Mean Roof Height: 12 ft.
JUL Risk Category: II
I
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 End 29 39 7 37.8 -50.6
12 Int 29 12 7 37.8 -41.0
13 Int 29 12 7 37.8 -41.0
14 Int 29 39 7 37.8 -41.0
I5 Int 29 39 7 37.8 -41.0
6 Int 13 67 7 37.7 -40.9
I
i
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code.
Page 1 of 1
i
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A GLAZING PRODUCT APPROVED PRESSURE RATING DESIGN PRESSURE M ROUGH WINDOW ARE
LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS
NUMBER or Interior OR DOOR TYPE NUMBER (+)PSF (-)PSF (+)PSF (-)PSF SIZE TESTED DIMENSIONS MULLION REQ Y/NMA REQ Y/N
1 End Window 11/16"Lami FL14604.7 75 75 37.8 -50.6 48 X 72 29x39 No No
2 Int Window 7/8"Lam' FL17162.1 85 90 37.8 1 -41.0 48 x 54 29x12 No No
3 Int Window 7/8"Lami FL17162.1 85 90 37.8 -41.0 48 X 54 29x12 No No
4 Int Window 11/16"Lami FL14604.7 75 75 37.8 -41.0 48 x 72 29x39 No No
5 Int Window 11/16"Lami FL14604.7 75 75 37.8 -41..0 48 X 72 2909 No No
6 Int Window 15116"Lami FL11409.2 55 55 37.7 -40.9 72 x 72 13x67 No No