HomeMy WebLinkAboutNOA DutcherMIAMI MIAMI-DADE COUNTY
IAM PRODUCT CONTROL SECTION
Eon11805 SW 26 Sheet, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-259D F(786) 315-2599
NOTICE OF ACCEPTANCE (NOA) wwrv.miamidadc.eov/cconomv
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Cade
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD°, Timberline' Natural Shadow', Timberline' American Harvest', and
FortitudeTM Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the pser by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
MIAMI DADECOUPRY
,...,
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category
Roofing
Sub -Category:
Asphalt Shingles
Materials:
Laminate
Deck Type:
Wood
SCOPE
This approves GAF Timberline HD®, Timberline® Natural Shadow', Timberline American® Harvest°, and
FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product
GAF Timberline HD°
Manufacturing
Locations #1, 2, 3, 4, 5, 6,7
GAF Timberline Natural
Shadow'
Manufacturing
Locations #1, 2, 3, 4, 5, 6,7
GAF Timberline° American
Harvest®
Manufacturing
Locations #2, 4, 5, 6
GAF FortitudeT^r
Manufacturing
Locations 01, 4
Dimensions Test Product Description
Specifications
13'/4"x393/8' TAS 110 Fiberglass reinforced heavyweight asphalt
roof shingle, with a laminate profile
13'/4"x 39 3/s"
131/4"x 39 3/s"
131/4"x 39*3/s"
MANUFACTURING LOCATION
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown, PA
5. Ennis, TX
6. Tuscaloosa, AL
7. Dallas, TX
TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
NOA No.: 16-0811.11
MIAMI•I)ADECOUMiY
...., , Expiration Date:02/21/22
Approval Date: 02/09/17
Page 2 of 6
EVIDENCE SUBMITTED
Test Aeencv
Test Identifier
Test Name/Report
Date
Underwriters Laboratories,LLC
ASTM D3462
4787344101
07/25/16
Underwriters Laboratories, Inc.
ASTM D3462
11CA48924
10/24/11
Underwriters Laboratories, Inc
ASTM D3462
1 OCA21994
04/22/11
Underwriters Laboratories, Inc
ASTM D3462
IOCA28717
07/26/11
Underwriters Laboratories, Inc.
ASTM D3462
05CA47541
11/10/06
Underwriters Laboratories, Inc.
ASTM D3462
06CA31580
11/30/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-101-02-02
11/02/05
Underwriters Laboratories, Inc.
ASTM D3462
06NK05159
08/09/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-098-02-02
11/08/05
Underwriters Laboratories, Inc.
ASTM D3462
02NK41809
08/11/02
Underwriters Laboratories, Inc.
ASTM D3462
03NK26444
10/17/03
Center for Applied Engineering
ASTM D3462
257989
05/13/97
Underwriters Laboratories, Inc.
TAS 107
01NK45803
04/13/94
Underwriters Laboratories, Inc.
TAS 107
06NK05159
08/09/06
Underwriters Laboratories, Inc.
TAS 107
04NK04273
02/20/04
Underwriters Laboratories, Inc.
TAS 107
05CA42840
11/11/05
Underwriters Laboratories, Inc.
TAS 107
02NK41811
11/11/02
Underwriters Laboratories, Inc.
TAS 107
03CA35209
10/17/03
Underwriters Laboratories, Inc.
TAS 107
04CA13850
08/30/04
Center for Applied Engineering
TAS 100
257989
04/01/97
PRI Asphalt Technologies, Inc.
TAS 100
GAF-044-02-01
01/13/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF-098-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-101-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-116-02-02
03/23/06
PRI Asphalt Technologies, Inc.
TAS-100
ELK 083-02-01
10/16/02
ELK-084-02-01
10/15/02
ELK-085-02-01
10/14/02
ELK-086-02-01
10/24/02
ELK-087-02-01
1O/21/02
ELK-088-02-01
10/16/02
ELK-107-02-01
10/09/03
ELK-108-02-01
10/09/03
ELK-109-02-01
10/09/03
LIIVIITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 16-0811.11
MIAM4DADE000Ntt Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS
I. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
MIAMECOUNTY NOA No.: 16-081111
4DAD
...., , Expiration Date-02121122
Approval Date: 02/09/17
Page 4 of 6
DETAIL A
COURSE LAYOUT
MIMt[•DADECOUNTY
NOA No.: 16-0811.11
• • • • � � Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 5 of 6
1
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/811
(1m)
T 14-1/2"-17-1/2 III III— 14-1/2"-17-12"
(368-445mm) I I �(30-445mm)
S-1/411 6-1f2"-9-1/2" Ilj�— I I 6-1/2"-g-1i2"
f337mm) --e- �.
'1rr-am•
APPROVED
ENHANCED NAILING PATTERN - six nails per shingle*
' required by some local codes and required for enhanced vrind coverage on certain products.
See firriled warranty for delails.
These shingles MUST be nailed a nominal 6" (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
Nail guide line
5J14'-6.114-
(146mm•159mm)
from Wom of shingle
adhesive
on back
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date:02/09117
Page 6 of 6