Loading...
HomeMy WebLinkAboutProduct approvals, Underlayment Approv:.. . .• BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links S b a _ p Product Approval d r 't +R `USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail - FL # FL11602-R10 Application Type Revision 72 Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740)321-6345 Greg. Keeler@owenscorning.com Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Keeler Greg Greg. Keeler@owenscorning.com Greg Keeler 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Profes Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Intertek Testing Services NA, Inc. - QA Entity 12/31/2020 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL11602 R10 COI 2019 01 COI NIEMINEN.pdf Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4798 2011 FRSA/TRI April 2012 2012 TAS 117(B) 1995 UL1897 2012 Product Approval Method Method 1 Option D Date Submitted 10/17/2019 Date Validated 10/17/2019 Date Pending FBC Approval 10/20/2019 Date Approved 12/10/2019 FL # Model, Number or Name $ Description i1602.1 Titanium Roof Underlayments Synthetic sheet -type roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL11602 RIO II 2019 10 FINAL ER FL11602-R1O.pdf Approved for use outside HVHZ: Yes Verified By: Robert Nieminen PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-45 Evaluation Reports Other: 1.) The design pressure noted herein pertains to use of a specific FL11602 RIO AE 2019 10 FINAL ER FL11602-R O.pdf underlayment system beneath foam -on tile sytsems. Refer to ER Section Created by Independent Third Party: Yes 5.6.3 for details. 2.) Refer to ER Sections 5 and 6 for other Limits of Use. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. (pyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not se electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuat Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email add they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wi: supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a license Chapter 455, F.S., please click here . Product Approval Accepts: W 99 Credit Card Safe NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 ut4 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740) 321-6345 Evaluation Report 111980.11.08-R11 FL11602-R10 Date of Issuance: 11/03/2008 Revision 11: 10/17/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titanium"' Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. ' ^ <; rr ;" The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCAANE1983 _1.,.,,,. Nieminen, P.E. on 10/17/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 92018 NEMO ETC, LLC ONEMO I etl ROOFING COMPONENT EVALUATION: 1. SCOPE. Product Category: Roofing Sub -Category: U nde rlayment Compliance Statement: TitaniumT"' Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. -STAN.,R. Section Property Standard Year 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull -through resistance TAS 117(B) 1995 3. REFERENCES Examination Entity Reference Date ERD (TST6049) Physical Properties 115010.04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520.06.11 06/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520.08.11-1 08/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS(TST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS(TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 ERD (TST6049) Physical Properties (NH) 4j-OC-19-SSUDL-01.A 06/14/2019 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI(TST5878) ASTM D1970; Tear strength OCF-332-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-343-02-01 11/09/2017 PRI (TST5878) ASTM D4798 OCF-341-02-01 11/27/2017 PRI (TST5878) TAS 117(B); Pull -through OCF-422-02-02 04/03/2018 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-425-02-01 08/13/2018 PRI (TST5878) ASTM D226/ ASTM D4798 OCF-331-02-01 R1 05/07/2019 PRI (TST5878) ASTM D226 / ASTM D4798 OCF-332-02-01 R1 05/07/2019 PRI (TST5878) ASTM D226 / ASTM D4798 OCF-334-02-01 R1 05/07/2019 PRI(TST5878) UL1897 1378TO02 07/10/2019 PRI (TST5878) Tensile adhesion OCF-507-02-01 08/13/2019 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 MEMO ETC, LLC Evaluation Report 111980.11.08-R11 Certificate of Authorization #32455 6�" EDITION (2017) FBC NON-€ VHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 2 of 8 Product Specification 4.1 Titanium"' PSU-30 ASTM D1970 Dubai, AE & ­b�inreinforced polymer modified bitumen material ad red and FRSA/TRI Bren ood, NH to the underside of apolymer-coated, synthetic wove April 2012 sheet. The underside is backed with a release film. nit ht 24 Ibs/square 4.2 TitaniumTM UDL-25 FBC 1507.1.1 Qingdao, China synthetic sheet -type un comprised of a woven & R905.1.1 core coated on one side with a polymer coating. Unit (Exception) weight 2.5 Ibs./square 4.3 TitaniumT1 UDL-30 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven & R905.1.1 Canada & core coated on both sides with a polymer coating. Unit (Exception) Qingdao, China weight 4.0 Ibs./square 4.4 TitaniumT" UDL-50 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven & R905.1.1 Canada & core coated on both sides with a polymer coating. Unit (Exception) Qingdao, China weight 4.7 Ibs./square LIMITATIONS:5. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 TitaniUMT" Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: C TA13LE 1: ROOF COVER OPTIONS - halt —` Asp— z Wood Shakes derl nayment. Shingles NaI n Tile Foam -On Tile Metal & Shingles Slate Titanium PSU-30 Yes es Yes Yes Yes Yes (See 5.5.1) Titanium - Yes No No Yes Yes Yes Yes Yes Titanium UDL-30 Yes (Base Sheet in 2-ply (Base Sheet in 2-ply Yes Yes Yes system) system) Titanium UDL-50 Yes No No Yes Yes Yes NEMO ETC, LLC Evaluation Report 111980.11.08-Rll Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-FHVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 3 of 8 NEMO I etc. 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlavment combinations 5.6 c 5.6.1 TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive Florida Product Approval Titanium PSU-30 DUPONT Tile Bond"" FL22525 ICP Adhesives Polyset® AH-160 FL6332 ICP Adhesives Polyset® RTA-1 FL6276 Allowable Substrates (for self -adhering): TABLE 2: SUBSTRATE OPTIONS Underlayment Primer Substrates Titanium PSU 30 (Optional) ASTM D41 plywood None ASTM D226 felt TM D41 Titanium UDL-30 None Titanium UDL-30 (inverted) #1 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies, Titanium PSU-30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #2 Maximum Design Pressure = -30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 1 Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance NEMO ETC` LLC Evaluation Report 111980.11.08-R11 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-RID Titanium Roof Underlayments Revision 11: 10/17/2019 Page 4 of 8 ONEMO I etc. #3 Maximum Design Pressure = -30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #4 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #5 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Titanium UDL-25, Titanium UDL-30, Titanium UDL-50 or Titanium PSU-30 shall not be left exposed for longer than 180-days. NEMO ETC, LLC Evaluation Report 111980.11.08-R11 Certificate of Authorization #32455 6;" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 5 of 8 ONEMO etc. 5.8 Tile Slippage Limitations (per FRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 3: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Titanium PSU-30 Flat Max. 10-tile stack 5:12 Flat Max 5-tile stack 6:12 Lugged Max. 10-tile stack 4:12 Lugged Max. 5-tile stack 5:12 Lugged Max. 10-tile stack (5 over 5) 5:12 INSTALLATION: NEMO ETC, LLC Evaluation Report 111980.11.08-R11 Certificate of Authorization #32455 6T" EDITION (2017) FEC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 6 of 8 6.3.3 6.3.4 Slopes of 4:12 or greater: fONEMOleti End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 25-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 25-inch side (horizontal) laps, resulting in a double -layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. TitaniurnT"" PSU-30: 6.4.1 Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. Titanium'" PSU-30 shall be back -nailed in accordance with Owens Corning published installation requirements. 6.4.2 Nail -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. Titanium" PSU-30 shall be back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Section 5.8 for tile staging limitations. 6.4.3 Foam -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April 2012 (04-12), and Owens Corning published requirements. TitaniumTM PSU-30 shall be back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer to Table 1A for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. 6.5 Titanium 2-Ply System: 6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. NEMO ETC, LLC Evaluation Report 111980.11.08-R31 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 7 of 8 6.5.3 6.5.4 UN Nail -On Tile Applications: For nail -on tile installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. Refer to Section 5.8 for tile staging limitations. Foam -On Tile Applications: For foam -on the installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6.4 Refer to Table 1A for allowable tile adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for tile staging limitations. 7-7-71 As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS - Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980.11.08-R11 certificate of Authorization #32455 67H EDITION (2017) FDC NON-HVHZ EVALUATION FL11602-R10 Titanium Roof Underlayments Revision 11: 10/17/2019 Page 8 of 8