Loading...
HomeMy WebLinkAboutLarry Gerardi Engineering0 0 I n r ----------------- i i 35'-0 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON -HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBG APPROVED PRODUCTS LIST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C101.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15. 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF -DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF -DRILLING SCREWS_ 8. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED_ NO WELDING ONSITE. ALL WELDING DONE IN SHOP BY A CERTIFIED WELDER. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,50OLB TENSILE STRENGTH. 10. 12 GA. FRAMING IS 2.5"x2.5" TUBE STEEL. NIPPLES ARE 2.25"x2.25" TUBE STEEL. SUB -GRADE SOILS: -TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION CONCRETE: -MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS -ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE REINFORCING STEEL (REBAR) REQUIREMENTS: -MINIMUM GRADE 40 STEEL -REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: -THE REBAR IS BENT COLD -THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BARDIAMETERS: AND -REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. -COVER: -2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 14" ELSEWHERE, REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF }" FOR FINE GROUT, AND 4" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN •2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 1j" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. GALVANIZATION: -METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED_ L -MIN. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER j MESH) AND 12"x12" REINFORCED FOOTER PERIMETER -----------------------------f R0jZL__6p ----------------------------------------------------- DOOR I- -2'—O" I —0„ J"x54" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END -WALL POST 2" MIN. --I I+ ABASE RAIL G II— —III -=11 a Iq2,500 PSI 4" —� I CONCRETE SLAB WITH ~12" W.W.F. OR FIBER MES1 MINIMUM SOIL BEARING CO)NTIINUOUSA WITH MINIMUM CAPACITY 2,000 PSF(TYP.) 12" OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL 2 5" PLAN VIEW DOOR FRAMING 1 if J" RECESS 4 OOR WIDTI I ELEVATION VIEW DOOR FRAMING " RECESS .75"T 4,. ---DOOR WIDTH - OPTIONAL ROLL—UP DOOR CONCRETE SPLASH—GUARD RECESS 12"02" REINFORCED FOOTER 0 I SWINGING o DOOR 10 ROLL -*UP I I 1 (CODE VERSION IFBC 2017 6th Edition�l ecrr_7_1n BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II -B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph ENCLOSURE JENCLOSED INTERNAL PRESSURE COEFF. +/- 0.18 IMPORTANCE FACTOR 11.0 ROOF DEAD LOAD 11OPSF FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE INO SQUARE FOOTAGE 11,050 SQ. FT. DATE MTB 6/20/20 2805 Grove Dr., St. Lucie ISIZE 351 X 30'W X 9'H II z Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA -1 OF 4 > z Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA -1 OF 4 N 3 12 ��3 " 3'–"T'6� 3'-4�" 10'-0" ROLL–UP i DOOR 0 I o 2'-0" ,0" D.C. 10'0" 3'-4 SWINGING m DOOR 1•_D^ - 6 I CA95ANWH CODE INFORMATION CODE VERSION FBC 2017 6th Edition ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II–B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph EXPOSURE B ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF, +/– 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 10PSF –0' 30'-0" FRONT END WALL 3'-5" 3'-5j" 3'-5" 3'-5 - �3._0"" Vtb 3'-8�-1" 3'–e 3'–e 3'–s�1" 3'–e1" 30'-0" REAR END WALL 3'–a�-1" 3'-61"� ROOF LIVE LOAD OPSF OR 3001b P.L. FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS, FLOOR, ROOF N/A O.C. MAX. 0 I MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,050 SQ. FT. REVISIONS 3'-1OJ" 11 3'-101" 3'-10j" REV DESCRIPTON DATE BY 2'-0" –0" 0 i ROLL–UP DOOR DRAWN BY: MTB DATE: 6/20/20 LOCATION: 2805 Grove Dr., St. Lucie SIZE: 35'L X 30'W X 9'H LEFT SIDE WALL 3'-10j" 35'-0" D.C. MAX. Li Ld �Jrq� zi 1 —3'– 10" 3'-101" 3'-101" 3'-101" RIGHT SIDE 3'-101" WALL 3'-1a1" 35'-0" 3'-101" 3'-1G1" 3'-1D1" W F 0 Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA—'Z OF 4 �► RTS ANYWHERE CODE INFOR ATION CODE VERSION FBC 2017 6th Edition ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CO STRUCTIO TYPE II -B SWINGING DOOR RISK CATEGORY I - BeOR FIRE PROTECTION NONE -""--'- —""""-'-- FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U o WIND SPEED Vult-165mph EXPOSURE B -....--------- ..-.—...—_...— --- ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. +/- 0-18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF I` 30'-0" FRONT END WALL I 30'-0" I REAR END WALL ROOFLIVELOAD 20PSFOR 3O01b P.L. FLOOR 1OPSF FLOOR LIVE LOAD 50PSF "R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,050 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 0 I BY: MTB ROM-upDRAWN -- DATE: 6/20/20 ----- — I.00AMON: 2805 Grove Dr., St. Lucie --- SIZE 35'L X 30'W X 9'H 36._0" LEFT SIDE WALL Cn W LLI llC J + £syr 3 7_ r _ - o 35'-0" RIGHT SIDE WALL W w 0 F Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA -3 OF4 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SCREWS #12-14xi- SELF—DRILLING NIPPLE TO `r \ BASE RAIL NIPPLE T BASE RAI POST TO BASE RAIL CONNECTION 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14)1- SELF—DRILLING SCREWS NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL INTERIOR #12-14x1" SELF—DRILLING SCREWS ® 10" O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM CORNERS VERTICALL' EXTERIOR DOOR FRAME TO POST CONNECTION MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12 14x1" SELF—DRILLING SCREW2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14x1" SELF—DRILLING SCREWS It 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14)j- SELF—DRILLING SCREWS 2"x2"x2" 16 GA, ANGLE CLIP SECURED WITH (4) #12-14)1- SELF—DRILLING SCREWS SINGLE OR DOUBLETS HEADER INTERMEDIATE POST TO END POST TO BASE RAIL HEADER -/BASE RAIL-/ OR HEADER CONNECTION CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 2"x2"x2" 16 GA. ANGLE CLIP SECURED WITH CREWS ) #12-14x1" SELF—DRILLING F ES 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14x1" SELF—DRILLING SCREWS ® NIPPLE\ NG 2-1-2-1' (6" O.C. (9" O.C. MAX.)) TO TRUSS/ TO. MA�3" MN .. 1i" MAX. SP*CING VARIES SIDE WALL ROLL—UP DOOR/FRAME OUT HEADER DETAIL INSTALL PER MANUFACTURERS INSTRUCTIONS #140" SELF—DRILLING SCREWS ® 6" 0_C_ MAX. & 6" MAX. FROM CORNE ROLL—UP DOOR TO POST CONNECTION DESIGN PRESSURES — 165 Mph ROOF +23.3/-51.6 FL27402.1 —R1 WALLS +25.4/-28.6 II—B DOORS +25.4/-28.6 FL27403.1 WINDOWS +25.4/-28.6 NONE SWINGING DOOR 1 2 3 407 STEEL DOOR 4 5 ZONE +12.0 —26.8 +14.9 —40.7 +23.3 —51.6 +24.2 —25.9 +25.4 —28.6 1" 16 GAUGE FURRING CHANNEL 48" O.C. MAX. SECURED WITH (2)#12-140" SELF—DRILLING SCREWS TO EACH RAFTER. ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION TO 1 "x2j" 16 GA. U—CHANNEL BRACE, MIN. 24" UP TO 7' POST, M$ 48" OVER 7' POST. MIN. 45' TO MAX. 60' FROM HORIZ. (EXCLUDE END—WALLS). SECURED WITH (4)#12-14x1" SELF—DRILLING SCREWS. MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH SC)REWS 14x1" SELF—DRILLING BOX EAVE RAFTER TO POST CONNECTION DETAIL RAI MINIMUM 6" TS NIPPLE. NIPPLE SCRSECURED TO WALL POST WITH CAMAMM� EWS 14x1" SELF—DRILLING SINGLE OR DOUBLETS HEADER HEADER CONNECTION DETAIL OPTION 2 MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14)j- SELF—DRILLING SCREWS POST TO TRUSS CONNECTION NIPPLE TRUSSED RAFTER CONNECTION DETAIL APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1 —R1 UTILITY STRUCTURE Hampton Rib Robf Panel II—B WALL SHEATHING Carports Anywhere FL27403.1 NONE Hampton Rib Wall Panel NONE SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 Vult-165mph 407 STEEL DOOR ROLL—UP DOOR JANUS INTERNATIONAL CORPORATION FL21450.3 SERIES 3100 CODE VERSION FBC 2017 6th Edition ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE ,FIRE SUPPRESSION SYSTEM NONE OCCUPANCY JUTILITY, U WIND SPEED Vult-165mph INTERNAL PRESSURE COEFF. +/— 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 3001b P.L. FLOOR DEAD LOAD 1OPSF FLOOR LIVE LOAD 50PSF -R-RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1,050 SQ. FT. DATE MTB 6/20/20 2805 Grove Dr., St. Lucie I- 35'L X 30'W X 9'H II zt ` J 3� s, MattheW T. BOIdWin P.E. Q Florida License #64608 C) Sheet: CA -4 OF 4