Loading...
HomeMy WebLinkAboutProduct approvals, Metal ApprovHI BSI la�ti,� ■usinessi Professional # # ♦ Regulation-� BCIS Home Log In User Registration ! Hot Topics i Submit Surcharge Stats & Facts ? Publications Contact Us BCIS Site Map Links S Product Approval USER: Public User Produce Approval Menu > Product or Application Search > Application List > Application Detail FL # FL21082 R2®� Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772)872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Profes Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A. Turner, P.E., MBA Validation Checklist - Hardcopy Received Certificate of Independence FL21082 R2 COI Dyn COI.%f Referenced Standard and Year (of Standard) Standard UL 580 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/20/2018 Date Validated 06/20/2018 Date Pending FBC Approval 06/27/2018 Date Approved 08/15/2018 Year 2006 of { FL # Model, Number or Name Description 21082.1 F+ Dynamic Metals 1"' Nailstrip Aluminum 1" Nail strip, .032 Aluminum, non-structural roof panel Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: Fasteners at 6" OC and 6" from ends. !75 (:: Installation Instructions FL21082 R2 II 210821D,pdf Verified By: Scott Wolters 62354 Created by Independent Third Party: Yes Evaluation Reports FL21082 R2 AE 210821E.pdf r'reated by indanandant Third E�'t... Voe- 21082.2 Dynamic Metals 1,5" Mech Seam 24g 1.5" Mechanical Seam, 24 gauge Galvalume coated steel, non-s uct Galvalume roof panel Limits of Use Insta Approved for use in HVHZ: No FL21082 R2 II 210822D p f Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A ` F �� Created by Independent Third Party: Yes Design Pressure: +NA/ 19 Evaluation Reports Other: Field Install Uplift DP 16"OC, 4"ends, eg�uals�1685�(includes FL21082 R2 AE 2I0822E.pFS=2) Corner Install Uplift DP''8" C, 4 en s, equals �'�Hicludes Created by Independent Third Party: Yes FS=2) 21082.3 Dynamic Metals 1.5" Mech Seam Aluminum 1.5" Mechanical Seam, .032 Aluminum, non-structural Limits of Use Installation Instructions Approved for use in HVHZ: No FL21082 R2 II 210823D.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-213,5 Evaluation Reports Other: Field Install Uplift DP: 16"OC, 4" ends, equals 131psf (includes FL21082 R2 AE 210823E.pdf FS=2) Corner Install Uplift DP: 8"OC, 4" ends, equals 213.5 psf (includes Created by Independent Third Party: Yes FS=2) 21082.4 Dynamic Metals 5V Crimp 26 ga Steel 5V Crimp, 26 ga Steel, Galvalume, non-structural Limits of Use Installation Instructions Approved for use in HVHZ: No FL21082 R2 II 210824D.pdf Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-206 Evaluation Reports f Other: Field Installation Uplift DP: 16" OC, 4" ends, equals 101 psf FL21082 R2 AE 210824E.pdf (Includes FS=2) Corner Installation Uplift DP: 8" OC, 4" ends, equals 206 Created by Independent Third Party: Yes psf (includes FS=2) Contact Us ;: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not se electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuai Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email add they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wi: supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a license Chapter 455, F.S., please click here . Product Approval Accepts: r_E Credit Card Safe WOLTERS ENGINEERING ENGINEERING, DRAFTING, CONSULTING 15211 97ffi Road N! West Palm Beach, FL 33412 Ph/Fx: (561) 225-1982 PRODUCT EVALUATION PRODUCT: DYNAMIC 11/2" MECHANICAL SEAM 24 GAUGE STEEL ROOF PANEL (FLPA# 21082.2) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD ST L_ 1 PALM BEACH WE , FL 3341 'It To all concerned, The Dynamic I V2" Mechanical Seam 24 Ga. Steel Roof Panel, manufactured by Dynamic Metals LLC, is a non-structural galvalume coated steel roof panel (50 ksi min) that meets the requirements of Section 1507,4.3 of the 6th Edition (2017) Florida Building Code. The panel has been tested per UL580-06 Architectural Testing, Inc. with results shown in test report G1 195 ).04-450-4 Technical Documentation: 1, Drawing "15MSS1624", dated 6/18118, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Charles Anderson, PE. 3. Supplemental Calculations to support "15MSS1624" drawing, signed and sealed by Scott Wolters, PE, I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed below and those provided in the documents above, this product meets all the requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, for use outside of the HVHZ. Limitations: This panel is approved for use outside of the HVHZ. Overall Limitations: Maximum Panel Width: 161, Minimum Rib Height: 1 Y2" Clip Anchors: 26 Ga galvanized steel, 2" long Field Installation Maximum Design Pressure: 168.5 ps-f. Panel Clip Anchor Spacing: 4" from ends, 16" max. O.G. Min. Panel Fastener: (2) #10xV Pancake head fast's per clip Panels are seamed to 9011. C 3PPI-0 0FFi%1\ Corner installatior Maximum Design Pressure: 198.5 psf Panel Clip Anchor Spacing: 4` from ends, 8" max. O.C, Min. Panel Fastener: (2) #1 Ox1 " Pancake head fast's per clip Panels are seamed to F.", layer of 30 lb. organic felt paper with 4" overlaps M Fire Barrier- 1 layer of VersaShield with 4" overlaps (or) Any fire barrier with a valid FLPA or Miami -Dade NOA Minimum Substrate: W(15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max, O.C. with 8d ring -shank nails spaced 4® O.C. Other Limitations: Roof slope must meet requirements of F8C Section 1507A.2. Fire classification is not a part of this evaluation. Shear diaphragm values are not a part of this evaluation. Design of substrate is by others and is not a part of this evaluation. If you have any questions or need more information concerning this approval please contact me. Thank you, X 401t Wo ers FL PE 4 62354 JUN 19 MO PVA L 11111111111111t r" ONI"