FL # FL21082 R2®�
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamicmetal.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Profes
Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A. Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence FL21082 R2 COI Dyn COI.%f
Referenced Standard and Year (of Standard) Standard
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
06/20/2018
Date Validated
06/20/2018
Date Pending FBC Approval
06/27/2018
Date Approved
08/15/2018
Year
2006
of
{ FL # Model, Number or Name Description
21082.1 F+ Dynamic Metals 1"' Nailstrip Aluminum 1" Nail strip, .032 Aluminum, non-structural roof panel
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-168.5
Other: Fasteners at 6" OC and 6" from ends. !75
(::
Installation Instructions
FL21082 R2 II 210821D,pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL21082 R2 AE 210821E.pdf
r'reated by indanandant Third E�'t... Voe-
21082.2
Dynamic Metals 1,5" Mech Seam 24g
1.5" Mechanical Seam, 24 gauge Galvalume coated steel, non-s uct
Galvalume
roof panel
Limits of Use
Insta
Approved for use in HVHZ: No
FL21082 R2 II 210822D p f
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A `
F ��
Created by Independent Third Party: Yes
Design Pressure: +NA/ 19
Evaluation Reports
Other: Field Install Uplift DP 16"OC, 4"ends, eg�uals�1685�(includes
FL21082 R2 AE 2I0822E.pFS=2)
Corner Install Uplift DP''8" C, 4 en s, equals �'�Hicludes
Created by Independent Third Party: Yes
FS=2)
21082.3
Dynamic Metals 1.5" Mech Seam Aluminum
1.5" Mechanical Seam, .032 Aluminum, non-structural
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21082 R2 II 210823D.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-213,5
Evaluation Reports
Other: Field Install Uplift DP: 16"OC, 4" ends, equals 131psf (includes
FL21082 R2 AE 210823E.pdf
FS=2) Corner Install Uplift DP: 8"OC, 4" ends, equals 213.5 psf (includes
Created by Independent Third Party: Yes
FS=2)
21082.4
Dynamic Metals 5V Crimp 26 ga Steel
5V Crimp, 26 ga Steel, Galvalume, non-structural
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21082 R2 II 210824D.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-206
Evaluation Reports
f Other: Field Installation Uplift DP: 16" OC, 4" ends, equals 101 psf
FL21082 R2 AE 210824E.pdf
(Includes FS=2) Corner Installation Uplift DP: 8" OC, 4" ends, equals 206
Created by Independent Third Party: Yes
psf (includes FS=2)
Contact Us ;: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not se
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuai
Section 455.275(l), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email add
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wi:
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a license
Chapter 455, F.S., please click here .
Product Approval Accepts:
r_E
Credit Card
Safe
WOLTERS ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
15211 97ffi Road N!
West Palm Beach, FL 33412
Ph/Fx: (561) 225-1982
PRODUCT EVALUATION
PRODUCT: DYNAMIC 11/2" MECHANICAL SEAM 24 GAUGE STEEL ROOF PANEL (FLPA# 21082.2)
MANUFACTURER: DYNAMIC METALS, LLC
340 PIKE ROAD
ST
L_ 1 PALM BEACH
WE , FL 3341 'It
To all concerned,
The Dynamic I V2" Mechanical Seam 24 Ga. Steel Roof Panel, manufactured by Dynamic Metals LLC, is a
non-structural galvalume coated steel roof panel (50 ksi min) that meets the requirements of Section 1507,4.3 of the
6th Edition (2017) Florida Building Code. The panel has been tested per UL580-06 Architectural Testing, Inc. with
results shown in test report G1 195 ).04-450-4
Technical Documentation:
1, Drawing "15MSS1624", dated 6/18118, signed and sealed by Scott Wolters, PE.
2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Charles Anderson, PE.
3. Supplemental Calculations to support "15MSS1624" drawing, signed and sealed by Scott Wolters, PE,
I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements of the 6th Edition (2017) Florida Building Code generally, and chapter 15 specifically, for use outside
of the HVHZ.
Limitations: This panel is approved for use outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 161,
Minimum Rib Height: 1 Y2"
Clip Anchors: 26 Ga galvanized steel, 2" long
Field Installation
Maximum Design Pressure: 168.5 ps-f.
Panel Clip Anchor Spacing: 4" from ends, 16" max. O.G.
Min. Panel Fastener: (2) #10xV Pancake head fast's per clip
Panels are seamed to 9011.
C 3PPI-0
0FFi%1\
Corner installatior
Maximum Design Pressure: 198.5 psf
Panel Clip Anchor Spacing: 4` from ends, 8" max. O.C,
Min. Panel Fastener: (2) #1 Ox1 " Pancake head fast's per clip
Panels are seamed to F.",
layer of 30 lb. organic felt paper with 4" overlaps
M
Fire Barrier-
1 layer of VersaShield with 4" overlaps
(or)
Any fire barrier with a valid FLPA or Miami -Dade NOA
Minimum Substrate: W(15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max,
O.C. with 8d ring -shank nails spaced 4® O.C.
Other Limitations: Roof slope must meet requirements of F8C Section 1507A.2.
Fire classification is not a part of this evaluation.
Shear diaphragm values are not a part of this evaluation.
Design of substrate is by others and is not a part of this evaluation.