Loading...
HomeMy WebLinkAboutGardner - FL26581_R1_II_No. 30 ASTM GGI-207-02-01 ASTM D226 T2� _. 0 gem 0) �r/ Lgaawr__ _�00� CONSTRUCTION MATERIALS LABORATORY TEST RESULTS TECHNOLOGIES Report for: Gardner Gibson Attention: Matt Mullins 4146 E. 7t" Avenue Tampa, FL 33605 Product Name(s): NO. 30 ASTM Manufacturer: Gardner Gibson PRI -CMT Project No.: GGI-207-02-01 Source: Gardner Gibson Date Received: January 31, 2018 Dates Tested: Feb. 26, 2018 — Mar. 5, 2018 Purpose: Evaluate NO. 30 ASTM for compliance with the physical properties of ASTM D 226 Asphalt -Saturated Felt Used in Roofing and Waterproofing, Type II. Test Methods: Testing was completed as described in ASTM D 226-09: Standard Specification for Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing. Test methods assigned or referenced include ASTM D 70: Standard Test Method for Density of Semi -Solid Bituminous Materials (Pycnometer Method); ASTM D 146: Standard Test Methods for Sampling and Testing Bitumen -Saturated Felts and Woven Fabrics for Roofing and Waterproofing; and ASTM D 6136: Standard Test Method for Kerosine Number of Unsaturated (Dry) Felt by Vacuum Method. Sampling: Product samples were provided by Gardner Gibson in Tampa, FL GGI-207-02-04 The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Construction Materials Technologies LLC 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materialstesting@pricmt.com WebSite: http://www.pricmt.com Gardner Gibson ASTM D 226 for NO. 30 ASTM Page 2 of 3 Results: ASTM D 226 Requirement Property Test Method Result Type I Type 11 Physical Requirements Breaking Strength (Ibf/in-width) 20 specimens; 1" x 6" x thickness; ASTM D 146 Cond. 2h @ 73.4±3.6°F & 50±5%RH; Test 73.4±3.6'F- Rate=2 i n/m i n Longitudinal (with fiber grain) 69 >_ 30 >_ 40 Transverse (across fiber grain) 32 _> 15 >_ 20 Pliability [Pass/Fail] 10 specimens; 1" x 8" x thickness -,3 D 146 �/" radius 3/" radius Cond. 10-15min in water @ 77±1.8°F; Test 90° around 1/2" radius in 2s Longitudinal (with fiber grain) Pass No Failures No Failures Transverse (across fiber grain) Pass No Failures No Failures Loss on Heating (weight %) 2 specimens; 12" x 6" x thickness; ASTM D 146 1 <_ 4 <_ 4 Test Cond. 221±5°F for 5h±3min Dimensions and Masses Width of Roll (in) ASTM D 146 36 36±1/4 36±1/4 Area, min (ft2) ASTM D 146 217 432 216 Moisture at Point of Manufacture (%) ASTM D 146 NT <_ 4.3 <_ 4.1 As Received' 1.0 <_ 4.3 <_ 4.1 Net Mass of Saturated Felt (Ib/100ft2) ASTM D 146 26 _> 11.5 >_ 26 Mass of Saturant (Ib/100ft2) ASTM D 146 15.0 >_ 6.2 >_ 15.0 Mass Ratio of Saturant to Desaturated Felt ASTM D 226 1.5 >_ 1.2 _> 1.5 Saturation Efficiency (%) ASTM D 226 71 ? 70 . . . Mass of Desaturated Felt (Ib/100ft2) ASTM D 146 10.0 ? 5.2 _> 10.0 Ash (%) ASTM D146 9.0 <_10.0 <_10.0 Continued on Following Page GG I-207-02-04 The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Construction Materials Technologies LLC 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materialstesting@pricmt.com WebSite: http://www.pricmt.com Gardner Gibson ASTM D 226 for NO. 30 ASTM Page 3 of 3 Note(s): 1- Moisture (As Received) was utilized in lieu of Moisture at Point of Manufacture; NT- Not Tested; NA- Not Applicable Statement of Compliance: The product was tested has demonstrated compliance with the physical requirements of Type II prescribed in ASTM D 226-09: Standard Specification for Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing. END OF REPORT GGI-207-02-04 The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Construction Materials Technologies LLC 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materialstesting@pricmt.com WebSite: http://www.pricmt.com Signed: Signed: Jason immons Duc T. Nguyen Director Florida Registered Professional Engineer PE No.: 65034 Date: Date.:_�t Q l 9 4 ^.� �w� ams G E N �a`,�� No 65434®� d-3 Report Issue History:spa 'ar. �, Issue # Date Pages Revision Description if applicablet "0 �o ��.� Original 03/08/2018 3 NA o,so 4QJ��r eel 1011�1 ?4� END OF REPORT GGI-207-02-04 The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Construction Materials Technologies LLC 6412 Badger Drive Tampa, FL 33610 Tel: 813-621-5777 Fax: 813-621-5840 e-mail: materialstesting@pricmt.com WebSite: http://www.pricmt.com