HomeMy WebLinkAboutCertificate for Design Load Compliancecomply with the applicable structural
Project Name:
Project Address:
Permit
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553
Certification for Design Load CompliandaEVIEWED FOR
cmon 22- CODE COMPLIANCE
DV.
Si. LU
Type: SF-V-- Construction Type:
INSTRUCTIONS FOR USE:
* This certification must be completed, signed, and sealed by the design professional of record.
Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family) C111= #%®V
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 BUilding Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category:_I X II _III_IV Exposure Category:_B X C D
4. Design Wind Velocity 160 mph__X ASD LRFD End Zone Width: 6 ft
S. Mean Roof Height 18 ft Roof Pitch: 6 12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +19.9, -31.7 Zone 2: +19.9, -55.1 Zone 3: +19.9, -81.5 Zone 4: +34.6, -37.5 Zone 5: +34.6, 46.3 Garage: +28.4, -34.7
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? —Yes X Not Applicable Explain Why Not:
Aspect Ratio <4:1
9. Is A Continuous Load Path Provided? X Yes_Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
portions of the building codes currently adopted and enforced by St. Lucie
!ments depicted on these plans provide adequate resistance to the design
Donald J. Nuelle P.E. 52046
Print Name Cert # & Co. Cert Auth.
Nuelle Engineering
11634 SW Rowena Street Port St. Lucie, FL 34987
Company Name & Address
Revised 12/07/2018