HomeMy WebLinkAboutEnergy CodeFORM R405-2017 • FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: OS-22 BUCHANAN. MARLIN 4 Builder Name: GHO HOMES Street 5816 BUCHANAN DR Permit Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34982 Permit Number. Owner. Jurisdiction: Design Location: FL, ST LUCIE_CO INTL County: St Lucie (Florida Climate Zone 2 ) 1. New construction or exlating New (From Plans) 9. Wall Types (2138.9 sqf .) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1858.90 ft, b. Frame - Wood, Adjacent R=11.0 280.00ft2 3. Number of units, if multiple family 1 a NIA R= fta 4. Number of Bedrooms 4 d, NIA R= ft' 5. Is this a worst case? No 10. Gelling Types (2120.0 sgft.) Insulation Area a. Under Attic (Vented) R=40.0 2120.00 ft 6. Conditioned floor area above grade (W) 2120 b, NIA R= ft2 Conditioned floor area below grade (ft) 0 c. NIA R= IN 11. Ducts R ft' 7. Windows(235.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Mein 6 623 a. U-Factor. Dbl, U=0.62 235.00 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A IF 12. Cooling systems kBtulhr Efficiency SHGC: a. Central Unit 39.0 SEER:16.00 c. U-Factor. N/A ft2 SHGC: 1. 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A ft a. Electric Strip Heat 21.2 COP:1.00 SHGC: S.r-2 n,�.tis�d4ii!@t� Area Weighted Average Overhang Depth: 3A13 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems+ R.,'. r- i,..C.A DOE 8. Floor Types (2120.0 sqa.) Insulation Area a. Electric F' a6 0 allons S p , LUCK C��J "�j'Wo a. Slab -On -Grade Edge Insulation R=0.0 2120.00 82 b. Conservation features ®y.> y,"C BOC b. WA R= ft- None c. N/A R= ft2 15. Credits Patel Glass/Floor Area: 0.111 Total Proposed Modified Loads: 66.73 PASS Total Baseline Loads: 70.57 FILE C I hereby certify that the plans and specifications covered by Review of the plans and 14 ST4r this calculation are in compliance with the Florida Energy specifications covered by thisOo s , BOA Code. ^ v ( >f calculation indicates compliance 7 with the Florida Energy Code. nn,: •, :-r .• � PREPARED BY: _______ --- Before construction Is completed � C DATE: -.. _. _._.__. _-_ _. 3/27/2020 this building will be Inspected for compliance with Section 553.908 I hereby cerli that ui as designed, is in compliance Flodda Statutes. !,), with the Florida ergy o e. COD {y>;'C�J OWNER/AGENT:._.1 _ - _ _- BUILDING OFFICIAL: DATE: -:_._ O DATE: --- - - _-._-- - Compliance requires certI1194 ion by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/26/2020 2:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: • Owner Name: # of Units: Bullder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: OS-22 BUCHANAN MARLIN Bedrooms: 4 User - Conditioned Area: 2120 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # BlocIdSubdivision: PlalBook: Street: 5816 BUCHANAN DR County. St. Lucie City, State, Zip: FORT PIERCE, FL, 34982 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE CO_INTL FL_VERO BEACH MUNI 39 90 70 75 299 58 Medium BLOCKS Number 1 Name Blockl Area Volume 2120 19716 SPACES Number Name Area Volume [Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2120 19716 Yes 5 4 1 Yes Yes Yes FLOORS # FloerType Space Perimeter R-Value Area Tile Wood Carpet _ 1 Siab-On•Grade Edge Insulatio Main 196.3 0 2120 ft' _ 0 0 _ 1 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emilt Emitt Deck Pitch Bare Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2371112 0 ft' Medium N 0.4 N 0.9 No 0 26.6 ATTIC If Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2120 tN N N CEILING Ceiling Type Space R-Value Ins Type Area _ Framing Free Truss Type 1 Under Attic (Vented) _ _ Main 40 Blown 2120 ft' 0.1 Wood 3/2612020 2:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software • Page 2 of 4 �r FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Speoe Cavity Width Height Sheathing Framing Solar Below Ome To WaILType-. _. a-velus F1 In R In Area a_Value-Fiactlon Ahsor-GradaY _ 1 N Exterior Concrete Block - Ext Insul Main 4.1 60 10 9 4 567.8 ft' 0 0 0.3 0 -2 E Exterior Concrete Block - Ext Insul Main 4.1 52 10 9 4 493.1 ft' 0 0 0.3 0 -3 S Exterior Concrete Block- Ext Insul Mein 4.1 56 2 9 4 524.2 ft' 0 0 0.3 0 -4 W Exterior Concrete Block- Ext Insul Main 4.1 29 4 9 4 273.8 ft' 0 0 0.3 0 5 - Garage Frame - Wood Main 11 30 0 9 4 280.0 ft' 0 0.25 0.3 0 DOORS # Omit Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Main None .39 3 8 24 ft WINDOWS Orientation shown is the entered. Proposed orientation. JWell Overhang _ # Omt ID Frame Panes_ U-Factor SHGC Imp Area Depth Separation_ Int Shade Screening 1 _ _NF_RC N 1 Metal Double (Clear) Yes 0.62 025 N _ 6.5 f11 It0 in 1 ft O In None _ None _ 2 E 2 Metal Double (Clear) Yes 0.62 025 N 52.0 ft' 1 it 0 in 1 it 0 In None None _ 3 E 2 Metal Double (Clear) Yes 0.62 025 N 64.0 IF 8 It 10 in 0 ft 4 in None None _ 4 E 2 Metal Double (Clear) Yes 0.62 025 N 21.7 IF 1 R 0 In 1 ft 0 in None None _ 5 S 3 Metal Double (Clear) Yes 0.62 025 N 6.5 IF 1 it 0 In 1 ft 0 in None None _ 6 S 3 Metal Double (Clear) Yes 0.62 025 N 21.7 ft' 1 ft 01n 1 ft 0 in None None _ 7 W 4 Metal Double (Clear) Yes 0.62 025 N 52.0 ft' 1 ft O in 1 ft 0 in None None 8 W 4 Metal Double (Clear) Yes 0.62 0.25 N 10.7 ft 7 It 21n 0 It 6 in None None GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 457 ft' 457 IF 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 2300.2 126.28 237.48 .1522 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity __ Block Duds 1 _ _ Electric Strip Heat/ None COPA 21.24 kBtulhr 1 sys#1 3/26/2020 2:30 PM EnergyGatigeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 39 kBtulhr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt .Conservation 1 Electric None Main 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Cool 1 Attic 8 623 ft' Attic 448 f12 Default Leakage Main. (Default) (Default) 1 1 TEMPERATURES Programeblfe TJhermosta((t:��Y Ceiling Fans: Heating Jan f>n Feb [[ ]] [)n Mar [ ] L 1 Apr € MayI►X]] Jul fD01 Aug tAugD01 S fSepf 11OctfX11 OctOcct Nov Nov Doc Dec Venting I 1 Jan O.Feb l J lRl Mar lxl May (] Jun [ ] [ ] p [X] [XJ Thermostat Schedule: HERS 2008 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Coating(WEH) AM 78 78' 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 ' PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 '68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .fL _ 0 g' Oft 0.3 _ Main 3126/2020 2:30 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location $ insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-famlly b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 39.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2120 d) Room unidPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 235.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior. 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and Insulation level a) Under attic b) Single assembly c) Knee walls/skyllght walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 21.2 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 0 Other 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other 10B1. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 40.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complieEnAnstalled th the Florida Building Code, Energy Conservation, through the above energy saving features which will be Installoexceeded) in this home before final Inspection. Otherwise, a now EPL display card will be completed bascode compliant features. Address of New Home: Date: 3 JSa ) t-e2u Clly/FL Zip: FORT PIERCE, FL 34982 3/26/2020 2:30:57 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 r GHO HOMES 05-22 6UCHANAN DR. FORT PIERCE, FL 54982