Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
wrightsoft° Load Short Form Entire House Project Information BUCHANAN DR, FORT PIERCE, FL 34982 Job: Date: Nov 13, 2019 By: Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (OF) 70 72 Construction quality Semi -tight Design TD (OF) 27 19 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 6.2 kW 21237 Btuh 15 OF 1300 cfm 0.049 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Lennox Trade 14ACX SERIES Cord 14ACX-041-230` Coil CBX27UH-048-230`++TDR AHRI ref 3869097 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.0 EER, 16 SEER 27300 Btuh 11700 Btuh 39000 Btuh 1300 cfm 0.045 cfm/Btuh 0 in H2O 0.72 ROOM NAME Area (fF) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) DINING 139 4273 4622 211 210 KITCHEN 192 1862 2328 92 106 GREAT RM 456 3603 4183 178 190 PANTRY 31 26 165 1 7 BATH2 63 1066 580 53 26 UTILITY 57 48 662 2 30 BEDHALL 39 33 64 2 3 BED 2 175 3194 3753 158 170 BED 3 175 2407 3453 119 157 FOYER 92 1244 1562 62 71 MASTER SUITE 254 4605 4032 228 183 HER WIC 57 48 208 2 9 MASTER BATH 129 870 593 43 27 HIS WIC 39 505 245 25 11 BED 4 160 2204 1994 109 90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Nov-1814:41:46 wrightsoft' Right -Suite® Universal 201212.1.05 RSU02818 Page AC;..rsVesonTocuments\Wnghtsoft HVACQS-22 BUCHANAN MARLIN 4.mp Colo= MJ8 Front Door faces: Entire House 2118 26267 28681 1300 1300 Other equip loads 0 0 Equip. @ 0.96 RSM 27390 Latent cooling 11167 I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsOft 201&Nov-Novt4Pag41 e 9 Right-Suite®Universa1207212.1.05 RSU02878 PaAe2 ...rsVason\0ocuments\Wrightsoft HVAC\0S-22 BUCHANAN MARLIN 4.rup Calc= MJB Fmnt 0corfaces: + wrightsoft' Project Summary Entire House For: Notes: OS-22 BUCHANAN DR, FORT PIERCE, FL 34982 Job: Date: Nov 13, 2019 By: Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TO 27 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure Ducts Central vent (0 cfm) Humidification Piping Equipment load Method Construction quality Fireplaces Infiltration 21847 Btuh 4420 Btuh 0 Btuh 0 Btuh 0 Btuh 26267 Btuh Simplified Semi -tight 0 Heating Cooling Area (fta) 2118 2118 Volume (ft� 20334 20334 Air changes/hour 0.22 0.11 Equiv. AVF (cfm) 75 37 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 6.2 kW 21237 Btuh 15 OF 1300 cfm 0.049 cfm/Btuh 0 in H2O Structure 23738 Btuh Ducts 4943 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 27390 Btuh Latent Cooling Equipment Load Sizing Structure 9599 Btuh Ducts 1568 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 11167 Btuh Equipment total load 38557 Btuh Req. total capacity at 0.70 SHR 3.3 ton Cooling Equipment Summary Make Lennox Trade 14ACX SERIES Cond 14ACX-041-230' Coil CBX27UH-048-230'++TDR AHRI ref 3869097 Efficiency 13.0 EER, 16 SEER Sensible cooling 27300 Btuh Latent cooling 11700 Btuh Total cooling 39000 Btuh Actual air flow 1300 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.72 Calculations approved by ACCA to meet all of Manual J 8th Ed. El Iwrl htSOft' 201&Nov-Nov g Right-8uile®Universe1201212.1.05 RSU02818 Pagel ACCA._rsUascn\Oocuments\Wnghlsoft HVAC\OS-22 BUCHANAN MARLIN 4.rup Calc=MJ8 Fmnt Doortaces: