Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENGINEERING (2)
DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5.1 ATTACHMENT PLAN 5.1 PV-5.2 ATTACHMENT PLAN 5.2 PV-5.3 ATTACHMENT PLAN 5.3 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN AP P E N D I X MODULE DATASHEET ARRAY WIRING BOX DATASHEET DISCONNECT DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 1703 CLASS A FIRE CERTIFICATION UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY ADDRESS 6804 WADSWORTH TERRACE, PORT ST. LUCIE, FL 34952 US ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1 OTHER BUILDING CODES 2017 FL BUILDING CODE CONTRACTOR INFORMATION COMPANY EFFICIENT HOME SERVICES ADDRESS 9416 INTERNATIONAL CT ST PETER, PALM BAY, FL 33716 PHONE NUMBER (844) 505-8144 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A PHOTOVOLTAIC POWER SYSTEM. SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 11.22KW AC RATING OF SYSTEM 9.57KW AC OUTPUT CURRENT 39.9A INVERTER(S)33 X ENPHASE IQ7PLUS-72-2-US MODULE Q-CELLS Q.PEAK DUO BLK-G6 340 ARRAY WIRING (1) BRANCH OF 7 IQ7PLUS-72-2-US MICROINVERTERS (2) BRANCH OF 13 IQ7PLUS-72-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.12(A) UTILITY SERVICE 120/240V 1Φ LOCATION INSIDE PANELBOARD, PROTECTED BY FUSED EATON DG222NRB , 2- POLE, 60A, 240VAC SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 160 MPH (ASCE7-10) RISK CATEGORY II WIND EXPOSURE CATEGORY B P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 PROJECT SUMMARY DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-1 I REYES M RUIZ DONATE PE# 88991 AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENTVERSION OF THE FLORIDA BUILDING CODE. This item has been signed and sealed byReyes Manuel Ruiz Donate, 88991PE on 7/16/2020using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 4 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 5:12 (23°) SLOPED ROOF, 22 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 297° AZIMUTH (N) VISIBLE, LOCKABLE, LABELED AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER (SW1), OUTDOOR (E) MAIN SERVICE PANEL (MSP), OUTDOOR (N) AC COMBINER (C1), OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (E) UTILITY METER, OUTDOOR (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 5:12 (23°) SLOPED ROOF, 7 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 117° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 5:12 (23°) SLOPED ROOF, 4 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 207° AZIMUTH ROADWAY P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 SITE PLAN DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-2 PV MODULE MICRO- INVERTER 7 IN BRANCH 13 IN BRANCH 13 IN BRANCH PM1-33 340W 1 2 3 4 5 6 AC COMBINER F3 20A 1 F1 20A F2 20A C1 AC GEC LOADS KWHRKWHR PV SYSTEM DISCONNECT UTILITY METER F4-5 50A SW1 60A (200A MSP W/200A MCB) 2 240/120V 1ɸ, 3W 7 8 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-33 33 Q-CELLS Q.PEAK DUO BLK-G6 340 340W 318W 10.52A 10.02A 40.7V 33.9V -0.11V/°C (-0.27%/°C)20A INVERTERS REF.QTY .MAKE AND MODEL AC VOLTAGE GROUND MAX OCPD RATING RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-33 33 ENPHASE IQ7PLUS-72-2-US 240V UNGROUNDED --290W 1.2A 15.0A 60V 97.0% PASS-THRU BOXES AND COMBINERS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE C1 1 ENPHASE Q AGGREGATOR OR EQUIV.48A 240VAC DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222NRB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE F1-3 3 20A 240VAC F4-5 2 50A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 BRANCH 3 INVERTERS PER BRANCH 13 13 7 MAX AC CURRENT 15.73A 15.73A 8.47A MAX AC OUTPUT 3,770W 3,770W 2,030W ARRAY STC POWER 11,220W ARRAY PTC POWER 10,505W MAX AC CURRENT 40A MAX AC POWER OUTPUT 9,570W DERATED AC POWER OUTPUT 9,570W NOTES THE DC AND AC CONNECTORS OF THE ENPHASE IQ7PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(A) AND NEC 690.17(E). 1 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703. THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. 2 UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) 3 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45(A). THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47 AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 4 AN ADDITIONAL ARRAY GROUNDING ELECTRODE SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTIONS 250.52 AND 250.54 UNLESS THE ARRAY STRUCTURE IS SUITABLE TO SERVE AS A GROUNDING ELECTRODE AS PER NEC SECTION 250.2, THE LOAD SERVED BY THE ARRAY IS INTEGRAL WITH THE ARRAY, OR THE PREMISE'S EXISTING WIRING ELECTRODE IS LOCATED WITHIN 6FT, AS PER NEC SECTION 690.47(D) 5 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 43.4V AT 0°C (0°C - 25°C) X -0.11V/C + 40.66V = 43.4V).6 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. 7 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER LOCALLY-APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.12(A). 8 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT / CABLE OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING 1 1 6 AWG THWN-2, COPPER 0.75" DIA. EMT 2 N/A 8 AWG THWN-2, COPPER 0.76 (55°C)1.0 39.93A 49.91A 75A 57A 75°C 65A 2 1 8 AWG THWN-2, COPPER 0.75" DIA. EMT 2 50A X 2 10 AWG THWN-2, COPPER 0.96 (33°C)1.0 39.93A 49.91A 55A 52.8A 75°C 50A REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE: GR I D - T I E D S O L A R P O W E R S Y S T E M PO R T S T . L U C I E , F L 3 4 9 5 2 68 0 4 W A D S W O R T H T E R PV-3 P-140417 07/16/20 SDT 140417 SINGLE-LINE DIAGRAM 1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE 5 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 6 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 7 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 8 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 4 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). SW1 - DISCONNECT (EATON DG222NRB ) MSP - MAIN SERVICE PANEL EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC 690.17(E) AC SOLAR DISCONNECT (SW1) PHOTOVOLTAIC AC DISCONNECT NEC 690.13(B) SEE NOTE NO. 4 (SW1) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN NEC 690.56(C) AND IFC 605.11.1 AC DISCONNECT (SW1) MAXIMUM AC OPERATING CURRENT: 39.9A MAXIMUM AC OPERATING VOLTAGE: 240V NEC 690.54 ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. NEC 705.12(D)(3) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN," SHALL BE LOCATED AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 3/8” TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 SAFETY LABELS DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-4 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 5/12 (22.6°) MEAN ROOF HEIGHT 13.7FT DECK SHEATHING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK-G6 340 DIMENSIONS (AREA)68.5IN X 40.6IN X 1.3IN (19.3 SQ FT) WEIGHT 43.9LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL QUICK MOUNT PV QMLM (FLASHED), 1.0IN AIR GAP FASTENING METHOD 3.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 23.8IN (ZONE 1) 15.8IN (ZONE 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 22 43.9 965.7 MICROINVERTERS 22 1.1 23.8 LINEAR FEET OF RAIL 259 FT 0.5 129.6 ANCHORS 96 1.0 98.0 MISC. HARDWARE 26.6 26.6 TOTAL ARRAY WEIGHT 1243.6 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 22 19.3 424.6 POINT LOAD (1243.6 LBS / 96 ATTACHMENTS)13.0 LBS DIST. LOAD (1243.6 LBS / 424.6 SQFT)2.93 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.5 FT = MAX(MIN(0.4 * 13.7 FT, 0.1 * 55.4 FT), 0.04 * 55.4 FT, 3 FT) P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 ATTACHMENT PLAN DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-5.1 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 5/12 (22.6°) MEAN ROOF HEIGHT 13.7FT DECK SHEATHING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK-G6 340 DIMENSIONS (AREA)68.5IN X 40.6IN X 1.3IN (19.3 SQ FT) WEIGHT 43.9LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL QUICK MOUNT PV QMLM (FLASHED), 1.0IN AIR GAP FASTENING METHOD 3.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 23.8IN (ZONE 1) 15.8IN (ZONE 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 4 43.9 175.6 MICROINVERTERS 4 1.1 4.3 LINEAR FEET OF RAIL 28 FT 0.5 14.1 ANCHORS 11 1.0 11.2 MISC. HARDWARE 4.7 4.7 TOTAL ARRAY WEIGHT 210.0 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 4 19.3 77.2 POINT LOAD (210.0 LBS / 11 ATTACHMENTS)19.1 LBS DIST. LOAD (210.0 LBS / 77.2 SQFT)2.72 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 5.5 FT = MAX(MIN(0.4 * 13.7 FT, 0.1 * 55.4 FT), 0.04 * 55.4 FT, 3 FT) P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 ATTACHMENT PLAN DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-5.2 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 5/12 (22.6°) MEAN ROOF HEIGHT 12.4FT DECK SHEATHING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK-G6 340 DIMENSIONS (AREA)68.5IN X 40.6IN X 1.3IN (19.3 SQ FT) WEIGHT 43.9LB MOUNTING SYSTEM PROPERTIES RAIL MODEL QUICK MOUNT PV QRAIL QMR-RL ANCHOR MODEL QUICK MOUNT PV QMLM (FLASHED), 1.0IN AIR GAP FASTENING METHOD 3.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. MOUNT SPACING 72.0IN (ZONE 1) 48.0IN (ZONE 2) 24.0IN (ZONE 3) MAX. ALLOW. CANTILEVER 23.8IN (ZONE 1) 15.8IN (ZONE 2) 7.9IN (ZONE 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 7 43.9 307.3 MICROINVERTERS 7 1.1 7.6 LINEAR FEET OF RAIL 85 FT 0.5 42.7 ANCHORS 39 1.0 39.8 MISC. HARDWARE 10.1 10.1 TOTAL ARRAY WEIGHT 407.5 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 7 19.3 135.1 POINT LOAD (407.5 LBS / 39 ATTACHMENTS)10.4 LBS DIST. LOAD (407.5 LBS / 135.1 SQFT)3.02 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7- 10). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.9 FT = MAX(MIN(0.4 * 12.4 FT, 0.1 * 55.4 FT), 0.04 * 55.4 FT, 3 FT) P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 ATTACHMENT PLAN DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-5.3 P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 ATTACHMENT DETAILS DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-6 GENERAL NOTES 1 ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS (WINDOWS OR DOORS), ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION, AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS (TREE LIMBS, WIRES, OR SIGNS). (NFPA 1 11.12.2.2.1.3) 2 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO CLOSER THAN 1-1/2 FEET TO A HIP OR VALLEY IF MODULES ARE TO BE PLACED ON BOTH SIDES OF THE HIP OR VALLEY. WHERE MODULES ARE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO BE PLACED DIRECTLY ADJACENT TO THE HIP OR VALLEY. (NFPA 1 11.10.2.2.2.1.3) 3 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS THAN 3 FT BELOW THE RIDGE. (NFPA 1 11.10.2.2.2.2) 2.0 FT. WIDE SMOKE-VENTILATION SETBACK 3.0 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.10.2.2.2.1.1 1.5 FT. WIDE FIRE ACCESS PATHWAY 0.5 FT. WIDE FIRE ACCESS PATHWAY 1.5 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.10.2.2.2.1.3 3.0 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.10.2.2.2.2 PV MODULES INSTALLED ON ROOF WITH QUICK MOUNT PV QRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 5/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1 OR 2 MODULES. THE Q-CELLS Q.PEAK DUO BLK-G6 340 IS TYPE 2. ROOF ACCESS POINT 1.5 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.10.2.2.2.1.3 AND NFPA 1 11.10.2.2.2.1.2 ROADWAY TOTAL PLAN VIEW ARRAY AREA IS 603.5 SQ.FT, WHICH REPRESENTS 22.4% OF TOTAL PLAN VIEW ROOF AREA (2695.6 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. P-140417 GR I D - T I E D S O L A R P O W E R S Y S T E M 68 0 4 W A D S W O R T H T E R PO R T S T . L U C I E , F L 3 4 9 5 2 FIRE SAFETY PLAN DOC ID:140417-173758-1 DATE:7/16/20 CREATOR: REVIEWER: REVISIONS PV-7 YI E L D S E C U R I T Y AN T I P I D T E C H N O L O G Y (A P T ) HO T - S P O T P R O T E C T (H S P ) TR A C E A B L E Q U A L I T Y (T R A . Q TM ) AN T I L I D T E C H N O L O G Y (A L T ) ww w . V D E i n f o . c o m I D . 4 0 0 3 2 5 8 7 Qu a l i t y T e s t e d hi g h r e l i a b i l i t y lo w d e g r a d a t i o n op t i m i z e d d u r a b i l i t y co n t i n o u s l i n e m o n i t o r i n g 11 / 2 0 1 6 EN Q. A N T U M T E C H N O L O G Y : L O W L E V E L I Z E D C O S T O F E L E C T R I C I T Y Hi g h e r y i e l d p e r s u r f a c e a r e a , l o w e r B O S c o s t s , h i g h e r po w e r c l a s s e s , a n d a n e f f i c i e n c y r a t e o f u p t o 1 9 . 5 %. IN N O V A T I V E A L L - W E A T H E R T E C H N O L O G Y Op t i m a l y i e l d s , w h a t e v e r t h e w e a t h e r w i t h ex c e l l e n t l o w - l i g h t a n d t e m p e r a t u r e b e h a v i o r . EN D U R I N G H I G H P E R F O R M A N C E Lo n g - t e r m y i e l d s e c u r i t y w i t h A n t i L I D a n d A n t i P I D T e c h n o l o g y 1 , Ho t - S p o t P r o t e c t a n d T r a c e a b l e Q u a l i t y T r a . Q ™ . E X T R E M E W E A T H E R R A T I N G Hi g h - t e c h a l u m i n u m a l l o y f r a m e , c e r t i f i e d f o r h i g h s n o w (5 4 0 0 Pa ) a n d w i n d l o a d s ( 4 0 0 0 Pa ) r e g a r d i n g I E C . A R E L I A B L E I N V E S T M E N T In c l u s i v e 1 2 - y e a r p r o d u c t w a r r a n t y a n d 2 5 - y e a r li n e a r p e r f o r m a n c e g u a r a n t e e 2 . ST A T E O F T H E A R T M O D U L E T E C H N O L O G Y Q. A N T U M D U O c o m b i n e s c u t t i n g e d g e c e l l s e p a r a t i o n an d i n n o v a t i v e w i r i n g w i t h Q . A N T U M T e c h n o l o g y . 1 A P T t e s t c o n d i t i o n s a c c o r d i n g t o I E C / T S 6 2 8 0 4 - 1 : 2 0 1 5 , m e t h o d B ( − 1 5 0 0 V, 1 6 8 h) 2 S e e d a t a s h e e t o n r e a r f o r f u r t h e r i n f o r m a t i o n TH E I D E A L S O L U T I O N F O R : Ro o f t o p a r r a y s o n re s i d e n t i a l b u i l d i n g s Q . P E A K D U O B L K - G 6 33 0 - 3 4 5 EN D U R I N G H I G H PE R F O R M A N C E α [% / K] + 0.04 β [% / K]− 0.27 γ [% / K] − 0.36 NMOT [°F]109 ± 5.4 (43 ± 3 °C)330 335 340 345 [W ] 330 335 340 345 [A ] 10.41 10.47 10.52 10.58 [V ] 40.15 40.41 40.66 40.92 [A ] 9.91 9.97 10.02 10.07 [V ] 33.29 33.62 33.94 34.25 [% ] ≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W ] 247.0 250.7 254.5 258.2 [A ] 8.39 8.43 8.48 8.52 [V ] 37.86 38.10 38.34 38.59 [A ] 7.80 7.84 7.89 7.93 [V ] 31.66 31.97 32.27 32.57 [V ] 1000 II [A D C ] 20 C (IEC) / TYPE 2 (UL) [l b s / ft 2 ] 75 ( 3 6 0 0 Pa ) / 55 ( 2 6 6 7 Pa) − 40 °F up to + 185 °F (− 40 °C up to + 85 °C) [l b s / ft 2 ] 11 3 ( 5 4 0 0 Pa ) / 84 ( 4 0 0 0 Pa) 3 S e e I n s t a l l a t i o n M a n u a l 32 28 24 71.5 × 45.3 × 46.9 in (1815 × 1150 × 1190 mm)1505 lbs (683 kg) Ce r t i f i e d UL 1 7 0 3 (2 5 4 1 4 1 ) Ha n w h a Q CE L L S A m e r i c a I n c . 40 0 S p e c t r u m C e n t e r D r i v e , S u i t e 1 4 0 0 , I r v i n e , C A 9 2 6 1 8 , U S A | TE L + 1 9 4 9 7 4 8 - 5 9 9 6 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.com/na ME C H A N I C A L S P E C I F I C A T I O N Fo r m a t 68 . 5 × 4 0 . 6 × 1 . 2 6 in ( i n c l u d i n g f r a m e ) (1 7 4 0 × 1 0 3 0 × 3 2 mm ) We i g h t 43 . 9 lb s ( 1 9 . 9 kg ) Fr o n t C o v e r 0. 1 3 in ( 3 . 2 mm ) t h e r m a l l y p r e - s t r e s s e d g l a s s wi t h a n t i - r e f l e c t i o n t e c h n o l o g y Ba c k C o v e r Co m p o s i t e f i l m Fr a m e Bl a c k a n o d i z e d a l u m i n u m Ce l l 6 × 2 0 m o n o c r y s t a l l i n e Q . A N T U M s o l a r h a l f c e l l s Ju n c t i o n B o x 2. 0 9 - 3 . 9 8 × 1 . 2 6 - 2 . 3 6 × 0 . 5 9 - 0 . 7 1 in ( 5 3 - 1 0 1 × 3 2 - 6 0 × 15 - 1 8 mm ) , P r o t e c t i o n c l a s s I P 6 7 , w i t h b y p a s s d i o d e s Ca b l e 4 mm ² S o l a r c a b l e ; ( + ) ≥ 45 . 3 in ( 1 1 5 0 mm ) , ( − ) ≥ 45 . 3 in ( 1 1 5 0 mm) Co n n e c t o r St ä u b l i M C 4 , A m p h e n o l U T X , R e n h e 0 5 - 6 , T o n g l i n g T L - C a b l e 0 1 S , JM T H Y J M 6 0 1 ; I P 6 8 o r F r i e n d s P V 2 e ; I P 6 7 No t e : I n s t a l l a t i o n i n s t r u c t i o n s m u s t b e f o l l o w e d . S e e t h e i n s t a l l a t i o n a n d o p e r a t i n g m a n u a l o r c o n t a c t o u r t e c h n i c a l s e r v i c e d e p a r t m e n t f o r f u r t h e r i n f o r m a t i o n o n a p p r o v e d i n s t a l l a t i o n a n d u s e of t h i s p r o d u c t . Specifications subject to technical changes © Q CELLS Q.PEAK DUO BLK-G6_330-345_2019-03_Rev01_NA EL E C T R I C A L C H A R A C T E R I S T I C S PO W E R C L A S S MI N I M U M P E R F O R M A N C E A T S T A N D A R D T E S T C O N D I T I O N S , S T C 1 ( P O W E R T O L E R A N C E + 5 W / −0 W) M i n i m u m Po w e r a t M P P 1 P MP P Sh o r t C i r c u i t C u r r e n t 1 I SC Op e n C i r c u i t V o l t a g e 1 V OC Cu r r e n t a t M P P I MP P Vo l t a g e a t M P P V MP P Ef f i c i e n c y 1 η MI N I M U M P E R F O R M A N C E A T N O R M A L O P E R A T I N G C O N D I T I O N S , N M O T 2 M i n i m u m Po w e r a t M P P P MP P Sh o r t C i r c u i t C u r r e n t I SC Op e n C i r c u i t V o l t a g e V OC Cu r r e n t a t M P P I MP P Vo l t a g e a t M P P V MP P 1 Me a s u r e m e n t t o l e r a n c e s P MP P ± 3 %; I SC ; V OC ± 5 % a t S T C : 1 0 0 0 W/ m 2 , 2 5 ± 2 °C , A M 1 . 5 G according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 G Q CE L L S P E R F O R M A N C E W A R R A N T Y PERFORMANCE AT LOW IRRADIANCE At l e a s t 9 8 % o f n o m i n a l p o w e r d u r i n g fi r s t y e a r . T h e r e a f t e r m a x . 0 . 5 4 % de g r a d a t i o n p e r y e a r . A t l e a s t 9 3 . 1 % of n o m i n a l p o w e r u p t o 1 0 y e a r s . A t le a s t 8 5 % o f n o m i n a l p o w e r u p t o 25 y e a r s . Al l d a t a w i t h i n m e a s u r e m e n t t o l e r a n c - es . F u l l w a r r a n t i e s i n a c c o r d a n c e w i t h th e w a r r a n t y t e r m s o f t h e Q CELLS sa l e s o r g a n i z a t i o n o f y o u r r e s p e c t i v e co u n t r y . Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TE M P E R A T U R E C O E F F I C I E N T S Te m p e r a t u r e C o e f f i c i e n t o f I SC Temperature Coefficient of V OC Te m p e r a t u r e C o e f f i c i e n t o f P MP P Normal Module Operating Temperature PR O P E R T I E S F O R S Y S T E M D E S I G N Ma x i m u m S y s t e m V o l t a g e V SY S Safety Class Ma x i m u m S e r i e s F u s e R a t i n g Fire Rating Ma x . D e s i g n L o a d , P u s h / Pu l l 3 Permitted Module Temperature on Continuous Duty Ma x . T e s t L o a d , P u s h / Pu l l 3 QU A L I F I C A T I O N S A N D C E R T I F I C A T E S PACKAGING INFORMATION UL 1 7 0 3 , V D E Q u a l i t y T e s t e d , C E - c o m p l i a n t , I E C 6 1 2 1 5 : 2 0 1 6 , I E C 6 1 7 3 0 : 2 0 1 6 , Ap p l i c a t i o n C l a s s I I , U . S . P a t e n t N o . 9 , 8 9 3 , 2 1 5 ( s o l a r c e l l s ) Number of Modules per Pallet Number of Pallets per 53' Trailer Number of Pallets per 40' HC-Container Pallet Dimensions (L × W × H)Pallet Weight 200 400 600 800 10001101009080RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²] EN R E L A T I V E E F F I C I E N C Y C O M P A R E D T O N O M I N A L P O W E R [ % ] 10 0 95 90 85 80 75 15 5 25 20 0 10 YE A R S 98 Q C E L L S In d u s t r y s t a n d a r d f o r t i e r e d w a r r a n t i e s * In d u s t r y s t a n d a r d f o r l i n e a r w a r r a n t i e s * *St a n d a r d t e r m s o f g u a r a n t e e f o r t h e 1 0 P V c o m p a n i e s wi t h t h e h i g h e s t p r o d u c t i o n c a p a c i t y i n 2 0 1 4 ( a s a t : S e p t e m b e r 2 0 1 4 ) NA DETAIL A 0.630" (16 mm)0.335" (8.5 mm)0.965" (24.5 mm)38.58" (980 mm)68.5" (1740 mm) 4 × Mounting slots (DETAIL A)Frame 40.5" (1030 mm)38.62" (981 mm)1.26" (32 mm)8 × Drainage holes15.0“ (380 mm)4 × Grounding points ø 0.177" (4.5 mm)Label≥45.3 " (1150 mm)≥45.3 " (1150 mm) Th e h i g h - p o w e r e d s m a r t g r i d - r e a d y En p h a s e I Q 7 M i c r o ™ a n d En p h a s e IQ 7 + M i c r o ™ dr a m a t i c a l l y s i m p l i f y t h e i n s t a l l a t i o n p r o c e s s w h i l e ac h i e v i n g t h e h i g h e s t s y s t e m e f f i c i e n c y . Pa r t o f t h e E n p h a s e I Q S y s t e m , t h e I Q 7 a n d IQ 7 + M i c r o i n v e r t e r s i n t e g r a t e w i t h t h e E n p h a s e IQ E n v o y ™ , E n p h a s e I Q B a t t e r y ™ , a n d t h e E n p h a s e En l i g h t e n ™ m o n i t o r i n g a n d a n a l y s i s s o f t w a r e . IQ S e r i e s M i c r o i n v e r t e r s e x t e n d t h e r e l i a b i l i t y st a n d a r d s s e t f o r t h b y p r e v i o u s g e n e r a t i o n s a n d un d e r g o o v e r a m i l l i o n h o u r s o f p o w e r - o n t e s t i n g , en a b l i n g E n p h a s e t o p r o v i d e a n i n d u s t r y - l e a d i n g wa r r a n t y o f u p t o 2 5 y e a r s . En p h a s e IQ 7 a n d I Q 7 + Mi c r o i n v e r t e r s To l e a r n m o r e a b o u t E n p h a s e o f f e r i n g s , v i s i t en p h a s e . c o m Da t a S h e e t En p h a s e M i c r o i n v e r t e r s Re g i o n : A M E R I C A S Ea s y t o I n s t a l l • Li g h t w e i g h t a n d s i m p l e • Fa s t e r i n s t a l l a t i o n w i t h i m p r o v e d , l i g h t e r t w o - w i r e c a b l i n g • Bu i l t - i n r a p i d s h u t d o w n c o m p l i a n t ( N E C 2 0 1 4 & 2 0 1 7 ) Pr o d u c t i v e a n d R e l i a b l e • Op t i m i z e d f o r h i g h p o w e r e d 6 0 - c e l l a n d 7 2 - c e l l * m o d u l e s • Mo r e t h a n a m i l l i o n h o u r s o f t e s t i n g • Cl a s s I I d o u b l e - i n s u l a t e d e n c l o s u r e • UL l i s t e d Sm a r t G r i d R e a d y • Co m p l i e s w i t h a d v a n c e d g r i d s u p p o r t , v o l t a g e a n d fr e q u e n c y r i d e - t h r o u g h r e q u i r e m e n t s • Re m o t e l y u p d a t e s t o r e s p o n d t o c h a n g i n g gr i d r e q u i r e m e n t s • C o n f i g u r a b l e fo r va r y i n g gr i d pr o f i l e s • Me e t s C A R u l e 2 1 ( U L 1 7 4 1 - S A ) * T h e I Q 7 + M i c r o i s r e q u i r e d t o s u p p o r t 7 2 - c e l l m o d u l e s . 1. N o e n f o r c e d D C / A C r a t i o . S e e t h e c o m p a t i b i l i t y c a l c u l a t o r a t ht t p s : / / e n p h a s e . c o m / e n - u s / s u p p o r t / m o d u l e - c o m p a t i b i l i t y . 2. N o m i n a l v o l t a g e r a n g e c a n b e e x t e n d e d b e y o n d n o m i n a l i f r e q u i r e d b y t h e u t i l i t y . 3. L i m i t s m a y v a r y . R e f e r t o l o c a l r e q u i r e m e n t s t o d e f i n e t h e n u m b e r o f m i c r o i n v e r t e r s p e r b r a n c h i n y o u r a r e a . To l e a r n m o r e a b o u t E n p h a s e o f f e r i n g s , v i s i t en p h a s e . c o m © 2 0 1 8 E n p h a s e E n e r g y . A l l r i g h t s r e s e r v e d . A l l t r a d e m a r k s o r b r a n d s u s e d a r e t h e p r o p e r t y o f E n p h a s e E n e r g y , I n c . 20 1 8 - 1 1 - 1 9 I N P U T D A T A ( D C ) I Q 7 - 6 0 - 2 - U S / I Q 7 - 6 0 - B - U S IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Co m m o n l y u s e d m o d u l e p a i r i n g s ¹ 23 5 W - 3 5 0 W + 235 W - 440 W + Mo d u l e c o m p a t i b i l i t y 60 - c e l l P V m o d u l e s o n l y 60-cell and 72-cell PV modules Ma x i m u m i n p u t D C v o l t a g e 4 8 V 60 V Pe a k p o w e r t r a c k i n g v o l t a g e 27 V - 3 7 V 27 V - 45 V Op e r a t i n g r a n g e 16 V - 4 8 V 16 V - 60 V Mi n / M a x s t a r t v o l t a g e 22 V / 4 8 V 22 V / 60 V Ma x D C s h o r t c i r c u i t c u r r e n t ( m o d u l e I s c ) 15 A 15 A Ov e r v o l t a g e c l a s s D C p o r t II II DC p o r t b a c k f e e d c u r r e n t 0 A 0 A PV ar r a y co n f i g u r a t i o n 1 x 1 u n g r o u n d e d a r r a y ; N o a d d i t i o n a l D C s i d e p r o t e c t i o n r e q u i r e d ; AC s i d e p r o t e c t i o n r e q u i r e s m a x 2 0 A p e r b r a n c h c i r c u i t OU T P U T D A T A ( A C ) I Q 7 M i c r o i n v e r t e r IQ 7+ Microinverter Pe a k o u t p u t p o w e r 2 5 0 V A 295 VA Ma x i m u m c o n t i n u o u s o u t p u t p o w e r 2 4 0 V A 290 VA No m i n a l ( L - L ) v o l t a g e / r a n g e ² 24 0 V / 2 1 1 - 2 6 4 V 208 V / 183-229 V240 V / 211-264 V208 V / 183-229 V Ma x i m u m c o n t i n u o u s o u t p u t c u r r e n t 1. 0 A ( 2 4 0 V ) 1.15 A (208 V)1.21 A (240 V)1.39 A (208 V) No m i n a l f r e q u e n c y 60 H z 60 Hz Ex t e n d e d f r e q u e n c y r a n g e 47 - 6 8 H z 47 - 68 Hz AC s h o r t c i r c u i t f a u l t c u r r e n t o v e r 3 c y c l e s 5. 8 A r m s 5.8 Arms Ma x i m u m u n i t s p e r 2 0 A ( L - L ) b r a n c h c i r c u i t ³ 16 ( 2 4 0 V A C ) 13 (208 VAC)13 (240 VAC)11 (208 VAC) Ov e r v o l t a g e c l a s s A C p o r t II I III AC p o r t b a c k f e e d c u r r e n t 0 A 0 A Po w e r f a c t o r s e t t i n g 1. 0 1.0 Po w e r f a c t o r ( a d j u s t a b l e ) 0. 8 5 l e a d i n g . . . 0 . 8 5 l a g g i n g 0.85 leading ... 0.85 lagging EF F I C I E N C Y @2 4 0 V @208 V @240 V @208 V Pe a k ef f i c i e n c y 9 7 . 6 % 97.6 %97.5 %97.3 % CE C we i g h t e d ef f i c i e n c y 9 7 . 0 % 97.0 %97.0 %97.0 % M E C H A N I C A L D A T A Am b i e n t t e m p e r a t u r e r a n g e -4 0 º C t o + 6 5 º C Re l a t i v e h u m i d i t y r a n g e 4% t o 1 0 0 % ( c o n d e n s i n g ) Co n n e c t o r t y p e ( I Q 7 - 6 0 - 2 - U S & I Q 7 P L U S - 7 2 - 2 - U S ) MC 4 ( o r A m p h e n o l H 4 U T X w i t h a d d i t i o n a l Q - D C C - 5 a d a p t e r ) Co n n e c t o r t y p e ( I Q 7 - 6 0 - B - U S & I Q 7 P L U S - 7 2 - B - U S ) Fr i e n d s P V 2 ( M C 4 i n t e r m a t e a b l e ) . Ad a p t o r s f o r m o d u l e s w i t h M C 4 o r U T X c o n n e c t o r s : - P V 2 t o M C 4 : o r d e r E C A - S 2 0 - S 2 2 - P V 2 t o U T X : o r d e r E C A - S 2 0 - S 2 5 Di m e n s i o n s ( W x H x D ) 21 2 m m x 1 7 5 m m x 3 0 . 2 m m ( w i t h o u t b r a c k e t ) We i g h t 1. 0 8 k g ( 2 . 3 8 l b s ) Co o l i n g Na t u r a l c o n v e c t i o n - N o f a n s Ap p r o v e d f o r w e t l o c a t i o n s Ye s Po l l u t i o n d e g r e e PD 3 En c l o s u r e Cl a s s I I d o u b l e - i n s u l a t e d , c o r r o s i o n r e s i s t a n t p o l y m e r i c e n c l o s u r e En v i r o n m e n t a l c a t e g o r y / U V e x p o s u r e r a t i n g NE M A T y p e 6 / o u t d o o r FE A T U R E S Co m m u n i c a t i o n Po w e r L i n e C o m m u n i c a t i o n ( P L C ) Mo n i t o r i n g En l i g h t e n M a n a g e r a n d M y E n l i g h t e n m o n i t o r i n g o p t i o n s . Bo t h o p t i o n s r e q u i r e i n s t a l l a t i o n o f a n E n p h a s e I Q E n v o y . Di s c o n n e c t i n g m e a n s Th e A C a n d D C c o n n e c t o r s h a v e b e e n e v a l u a t e d a n d a p p r o v e d b y U L f o r u s e a s t h e l o a d - b r e a k di s c o n n e c t r e q u i r e d b y N E C 6 9 0 . Co m p l i a n c e CA R u l e 2 1 ( U L 1 7 4 1 - S A ) UL 6 2 1 0 9 - 1 , U L 1 7 4 1 / I E E E 1 5 4 7 , F C C P a r t 1 5 C l a s s B , I C E S - 0 0 0 3 C l a s s B , CA N / C S A - C 2 2 . 2 N O . 1 0 7 . 1 - 0 1 Th i s p r o d u c t i s U L L i s t e d a s P V R a p i d S h u t D o w n E q u i p m e n t a n d c o n f o r m s w i t h N E C - 2 0 1 4 a n d NE C - 2 0 1 7 s e c t i o n 6 9 0 . 1 2 a n d C 2 2 . 1 - 2 0 1 5 R u l e 6 4 - 2 1 8 R a p i d S h u t d o w n o f P V S y s t e m s , f o r A C an d D C c o n d u c t o r s , w h e n i n s t a l l e d a c c o r d i n g m a n u f a c t u r e r ’ s i n s t r u c t i o n s . En p h a s e I Q 7 a n d I Q 7 + M i c r o i n v e r t e r s QR a i l — F u l l y I n t e g r a t e d M o u n t i n g a n d R a c k i n g S y s t e m Th e Q R a i l S e r i e s i s a s t r o n g a n d v e r s a t i l e s o l a r a r r a y m o u n t i n g s y s t e m t h a t p r o v i d e s u n r i v a l e d b e n e f i t s t o s o l a r de s i g n e r s a n d i n s t a l l e r s . C o m b i n e d w i t h Q u i c k M o u n t P V ’ s i n d u s t r y - l e a d i n g w a t e r p r o o f m o u n t s , Q R a i l o f f e r s a co m p l e t e r a c k i n g s o l u t i o n f o r m o u n t i n g s o l a r m o d u l e s o n a n y r o o f . QR a i l , t o g e t h e r w i t h Q u i c k M o u n t P V ’ s w a t e r p r o o f m o u n t i n g p r o d u c t s , p r o v i d e s t h e b e n e f i t o f a s i n g l e - s o u r c e d , se a m l e s s l y i n t e g r a t e d r o o f t o p i n s t a l l a t i o n t h a t w o r k s w i t h a l l r o o f t y p e s — c o m p o s i t i o n / a s p h a l t s h i n g l e s , fl a t o r c u r v e d t i l e , m e t a l s h i n g l e , s h a k e , s l a t e a n d l o w s l o p e r o o f s . T h e Q R a i l s y s t e m a l s o w o r k s w i t h a n y r o o f at t a c h m e n t s y s t e m f o r m a x i m u m f l e x i b i l i t y . Co m p r e h e n s i v e , O n e - S o u r c e S o l u t i o n Fa s t , S i m p l e I n s t a l l a t i o n : I t J u s t C l i c k s Th e Q R a i l s y s t e m p r o v i d e s a n i n t e g r a t e d e l e c t r i c a l b o n d i n g p a t h , e n s u r i n g t h a t a l l e x p o s e d m e t a l p a r t s a n d th e s o l a r m o d u l e f r a m e s a r e e l e c t r i c a l l y c o n n e c t e d . A l l e l e c t r i c a l b o n d s a r e c r e a t e d w h e n t h e c o m p o n e n t s a r e in s t a l l e d a n d t i g h t e n e d d o w n . Fu l l y I n t e g r a t e d E l e c t r i c a l B o n d i n g QC l i c k T e c h n o l o g y Th e u n i v e r s a l m i d a n d e n d c l a m p s u s e p a t e n t e d Q C l i c k te c h n o l o g y t o s i m p l y “ c l i c k ” i n t o t h e r a i l c h a n n e l a n d re m a i n u p r i g h t , r e a d y t o a c c e p t t h e m o d u l e . T h e pr e - a s s e m b l e d c l a m p s f i t v i r t u a l l y a l l m o d u l e f r a m e s a n d re q u i r e n o e x t r a h a r d w a r e , e l i m i n a t i n g p r e - l o a d i n g a n d re d u c i n g i n s t a l l a t i o n t i m e . Su p e r i o r S t r e n g t h a n d V e r s a t i l i t y QR a i l i s e n g i n e e r e d f o r o p t i m a l s t r u c t u r a l p e r f o r m a n c e . T h e s y s t e m i s c e r t i f i e d t o U L 2 7 0 3 , f u l l y c o d e c o m p l i a n t a n d b a c k e d b y a 2 5 - y e a r wa r r a n t y . Q R a i l i s a v a i l a b l e i n L i g h t , S t a n d a r d a n d H e a v y v e r s i o n s t o ma t c h a l l g e o g r a p h i c l o c a t i o n s . Q R a i l i s c o m p a t i b l e w i t h v i r t u a l l y a l l mo d u l e s a n d w o r k s o n a w i d e r a n g e o f p i t c h e d r o o f s u r f a c e s . M o d u l e s ca n b e m o u n t e d i n p o r t r a i t o r l a n d s c a p e o r i e n t a t i o n i n s t a n d a r d o r sh a r e d - r a i l c o n f i g u r a t i o n s . S TA N D A R D L IG H T 1 2 3 click !click!2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL E ND C L AMP 2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL B ONDED M ID C L AMP QR a i l ’ s i n n o v a t i v e i n t e r n a l Q S p l i c e i n s t a l l s i n s e c o n d s , r e q u i r i n g n o to o l s o r s c r e w s . S i m p l y i n s e r t Q S p l i c e i n t o t h e r a i l a n d s l i d e t h e o t h e r ra i l o n t o c r e a t e a f u l l y s t r u c t u r a l , b o n d e d s p l i c e . A n e x t e r n a l s p l i c e i s al s o a v a i l a b l e . QS p l i c e T e c h n o l o g y QS P L I C E H EA V Y QR a i l s c o m e i n t w o l e n g t h s — 16 8 i n c h e s ( 1 4 f t ) a n d 2 0 8 i n c h e s ( 1 7 . 3 f t ) ™ ™ 2 3 1 Mi l l a n d B l a c k F i n i s h In s t a l l s i n s e c o n d s — n o t o o l s o r h a r d w a r e r e q u i r e d In s t a l l i n g i s a s e a s y a s 1 - 2 - 3 Ea s i l y d e s i g n a r r a y c o n f i g u r a t i o n s w i t h t h e Q D e s i g n s o f t w a r e ap p l i c a t i o n . G e n e r a t e c o m p l e t e e n g i n e e r i n g r e p o r t s a n d c a l c u l a t e a p r e c i s e b i l l o f m a t e r i a l s f o r a l l t h e m o u n t i n g , r a c k i n g a n d ac c e s s o r i e s n e e d e d f o r a c o m p l e t e s o l a r a r r a y . ™ 1 AVAILABLE IN MILL, AND BLACK FINISHES 234 *5 * STRUCTURAL SCREW AVAILABLE ON QMLM-ST VERSIONS ONLY 3 . 3 0 . 0 4 0 3 . 5 4 2 . 0 0 . 9 0 2 . 5 0 .3 9 7 2 . 0 9 1 . 0 0 QM L M 3 . 0 0 4 . 5 0 9 . 0 0 1 2 . 0 0 4 . 2 0 TH I S E D G E T O W A R D S R O O F R I D G E 4 . 0 4 2 . 7 5 QM L M - S T IT E M NO . DE S C R I P T I O N QTY. 1 FL A S H I N G , R O U N D E D C O R N E R S , 9 " X 1 2 " X . 0 4 0 " , . 4 3 8 " H O L E , 5 0 5 2 , MI L L 1 2 L- F O O T , 2 " X 3 . 3 0 " F O R . 4 3 8 " O . D . F A S T E N E R , 2 - 1 / 1 6 " S L O T , 6 0 6 1 - T6 / 6 0 0 5 A - T 6 1 , M I L L 1 3 WA S H E R , S E A L I N G , 5 / 1 6 " I D X 3 / 4 " O D , E P D M B O N D E D S S 1 4 LA G S C R E W , H E X H E A D , 5 / 1 6 " x 4 " , 1 8 - 8 S S 1 *5 ST R U C T U R A L S C R E W , Q M P V , T - 3 0 H E X W A S H E R H E A D , 5 / 1 6 " X 4 - 1 / 2 " , 18 - 8 S S 1 9 DO N O T S C A L E D R A W I N G SHEET 1 OF 1RAD SCALE: 1:4 WEIGHT:REV ASIZE TI T L E : DATE:DRAWN BY: DI M E N S I O N S A R E I N I N C H E S TO L E R A N C E S : FR A C T I O N A L 1 / 8 TW O P L A C E D E C I M A L .1 9 TH R E E P L A C E D E C I M A L .0 9 4 PR O P R I E T A R Y A N D C O N F I D E N T I A L TH E I N F O R M A T I O N C O N T A I N E D I N T H I S D R A W I N G I S T H E S O L E P R O P E R T Y O F Q U I C K M O U N T P V . A N Y R E P R O D U C T I O N I N P A R T O R A S A W H O L E W I T H O U T T H E WR I T T E N P E R M I S S I O N O F Q U I C K M O U N T P V I S P R O H I B I T E D . CO P Y R I G H T © 2 0 1 6 Q U I C K M O U N T P V 5 4 3 2 1 UN L E S S O T H E R W I S E S P E C I F I E D : 1.0723 QM L M & Q M L M - S T : L - M O U N T , 2- 1 / 1 6 " S L O T 7/16/2018