Loading...
HomeMy WebLinkAbout7982 steeplechase ct final approSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: John Fogleman AGENT: Oakmont Custom Homes, LLC PROPERTY ADDRESS: 7982 Steeplechase Ct Port Saint Lucie, FL 34986 LOT: 118 BLOCK: APPLICATION # : AP 1368770 PERMIT #: 56-SF-1 884557 DOCUMENT #:F11453049 DATE PAID.10/15/2018 FEE PAID:515.00 RECEIPT #:56-PID-3770380 SUBDIVISION: Sabal Creek II ID#: 3321-502-0067-000-3 CHECKED [X) ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [01) TANK SIZE [11 1090.00 [2) 483.00 [02) TANK MATERIAL Polypropylene [03) OUTLET DEVICE [04) MULTI -CHAMBERED [LZJ N ) [05) OUTLET FILTER Polylok PL-68 [06) LEGEND 1, 70-143-11SC4 [07) WATERTIGHT [08) LEVEL [09) DEPTH TO LID DRAINFIELD INSTALLATION [10) AREA [1) 769.76 [21 [11) DISTRIBUTION BOX [12) NUMBER OF DRAINLINES [13) DRAINLINE SEPARATION [14) DRAINLINE SLOPE [15) DEPTH OF COVER [16) ELEVATION [ ABOVE / [17) SYSTEM LOCATION (18) DOSING PUMPS [19) AGGREGATE SIZE [20) AGGREGATE EXCESSIVE FINE! [211 AGGREGATE DEPTH FILL / EXCAVATION MATERIAL [ ) [22) FILL AMOUNT [ ) [23) FILL TEXTURE [ ) [24) EXCAVATION DEPTH [ ) [25) AREA REPLACED [ ) [26) REPLACEMENT MATERIAL Comments: Comments are on naae 2. 2. 70-143-54SC4 SQFT HEADER X 1. 6.00 2. BELOW IBM 2.00 1.00 CONSTRUCTION [ APPROVED / DISAPPROVED ): SETBACKS [ ) [27) SURFACE WATER FT [ ) [28) DITCHES FT [ ) [291 PRIVATE WELLS 100 FT [ ) [30) PUBLIC WELLS FT [ ) [31) IRRIGATION WELLS FT [ ) [32) POTABLE WATER 100 FT [ ) [33) BUILDING FOUNDATIONS 21 FT [ ) [34) PROPERTY LINES 43 FT [ ) [35) OTHER FT FILLED / MOUND SYSTEM [ ) [36) DRAINFIELD COVER [ ) [37) SHOULDERS [ ) [38) SLOPES [ ) [39) STABILIZATION 07/28/2020 ADDITIONAL, INFORMATION [ ) [40) UNOBSTRUCTED AREA [ ) (41) STORMWATER RUNOFF [ ) [421 ALARMS [ ) [43) MAINTENANCE AGREEMENT [ ) [44) BUILDING AREA [ ) [45) LOCATION CONFORMS WITH SITE PLAN [ ) [461 FINAL SITE GRADING [ ) [471 CONTRACTOR Brian Davis (Brian Davis Sept [ ) [48) OTHER INFILTRATOR Quick4 Plus EQ36 LP ABANDONMENT [ ) [49) TANK PUMPED [ ) [50) TANK CRUSHED & FILLED ..�.�_ St. Lucie CHD J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED 7: St. Lucie CHD Environmental Specialist Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1368770 EID1884557 DATE: 01 /09/2020 DATE: 07/28/2020 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1368770 PERMIT #:56-SF-1884557 DOCUMENT #:F11453049 DATE PAID:10/15/2018 FEE PAID:515.00 RECEIPT #:56-PID-3770380 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 460 gpd. New 1090 ST and 483 ST installed in series. New filter, 483 DT(70-143-54SC4), liberty 1/3 hp pump, and 4x11+2x12 BED DF installed. No violations, system ok to cover. Contractor notified by email. Needs final inspection for mound system and final site grading. Well inspected at construction inspection. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1368770 EID1884557