HomeMy WebLinkAboutHealth Department ApprovalSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: Wade Jurney Homes, LLC
AGENT: Wade Jurney Homes, LLC
PROPERTY ADDRESS: 7601 Miramar Ave Fort Pierce, FL 34951
LOT: 27
BLOCK: 5
APPLICATION #: AP 1413820
PERMIT #:56-SF-1948844
DOCUMENT #.F11453033
DATE PAID:05/13/2019
FEE PAID:515.00
RECEIPT #:56-PID-3939637
SUBDIVISION: Lakewood Park ID#: 1301-601-0073-000-4
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [1] 1050.00 [2] [
]
[27]
SURFACE WATER
FT
[ ] [021
TANK MATERIAL Concrete [
]
[281
DITCHES
FT
[ ] [03]
OUTLET DEVICE (
]
[29]
PRIVATE WELLS 100
FT
[ ] [04]
MULTI -CHAMBERED [ Y N ] [
]
[30]
PUBLIC WELLS
FT
( ] [05]
OUTLET FILTER Polylok PL-68 [
]
[311
IRRIGATION WELLS
FT
[ ] [06]
LEGEND 1. 28-015-03DC4 2. [
]
[321
POTABLE WATER 29
FT
[ ] [07]
WATERTIGHT [
]
[33]
BUILDING FOUNDATIONS
6 FT
[ ] [08]
LEVEL [
]
[34]
PROPERTY LINES 9
FT
[ ] [09]
DEPTH TO LID [
]
[35]
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] (10]
AREA (1] 501 [2] SQFT [
]
[361
DRAINFIELD COVER
] (11]
DISTRIBUTION BOX HEADER X [
]
[37]
SHOULDERS
[ ] [121
NUMBER OF DRAINLINES 1. 6.00 2. (
]
[38]
SLOPES
[ ] [13]
DRAINLINE SEPARATION [
]
[391
STABILIZATION 07/27/2020
[ ] [14]
DRAINLINE SLOPE
[ ] (151
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [16]
ELEVATION [ ABOVE / BELOW ]BM 1.00 [
]
[401
UNOBSTRUCTED AREA
[ ] [17]
SYSTEM LOCATION [
]
[41]
STORMWATER RUNOFF
[ ] [181
DOSING PUMPS (
]
[42]
ALARMS
[ ] [19]
AGGREGATE SIZE [
]
[431
MAINTENANCE AGREEMENT
[ ] [20]
AGGREGATE EXCESSIVE FINES [
]
[44]
BUILDING AREA
[ ] [21]
AGGREGATE DEPTH [
]
[45]
LOCATION CONFORMS WITH SITE
PLAN
[
]
[461
FINAL SITE GRADING
FILL /
EXCAVATION MATERIAL
[ ] [22]
FILL AMOUNT [
]
[47]
CONTRACTOR Bruce T Mc Cullers (Reliable T
[ ] [23]
FILL TEXTURE [
]
[48]
OTHER ADS MPS-9 (9 pipes
- 2 tier)
[ ] [24]
EXCAVATION DEPTH
ABANDONMENT
[ ] [25]
AREA REPLACED [
]
[49]
TANK PUMPED
[ ] [261
REPLACEMENT MATERIAL [
]
[50]
TANK CRUSHED & FILLED
Comments: Comments
are on page 2.
CONSTRUCTION
( APPROVED /
St. Lucie CHD DATE: 05/27/2020
DISAPPROVED Enviro ental Specialist II
J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM
( APPROVED / DISAPPROVED ] :
St. Lucie CHD DATE: 07/27/2020
ErWironmental Specialist
rian J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of
Violations on following page)
DH 4016, 08/09
(Obsoletes all previous editions which may not
be used)
Incorporated:
64E-6.003, FAC
Page
2 of 3
EH Database v 1.0.1 AP1413820
EID1948844
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION # : AP 1413820
PERMIT #:56-SF-1948844
DOCUMENT #: F11453033
DATE PAID - 05/13/2019
FEE PAID:515.00
RECEIPT #:56-PID-3939637
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, filter, and 4x26'+2x33' long TRENCH DF installed. No violations, system ok to cover. Contractor notified by phone.
Needs final inspection for mound system, gutters, and final site grading.
Final system approved. Contractor, building department, and builder emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1413820 EID1948844