HomeMy WebLinkAboutPlans.pdf7 6
5
Egress
4
3
2
1
Main Door, Egress
12
11
10
Egress
9
8
Egress
PAGE:
1
OF
1
PAGE DESCRIPTION:
Site Plan
DATE:
Jul 20, 2020
SCALE:
NOT TO SCALE
COPYRIGHT E-TEMPEST.COM
Li
n
d
a
M
i
n
t
o
n
24
5
1
S
F
F
A
R
o
a
d
Fo
r
t
P
i
e
r
c
e
,
F
L
3
4
9
4
5
Opening Size
(W x H)
1.37 x 81X Outswing Door
(Series 160)
17-1226.05
2.74 x 63OX Horizontal Rolling Window
(Series 120)
17-0918.09
3.74 x 63XO Horizontal Rolling Window
(Series 120)
17-0918.09
4.26 x 50Single Hung Window
(Series 110)
17-1018.08
5.74 x 63OX Horizontal Rollling Window
(Series 120)
17-0918.09
6.96 x 80XO Sliding Glass Door
(Series 4130)
FL29078.2
7.37 x 63Single Hung Window
(Series 110)
17-1018.08
8.74 x 38OX Horizontal Rolling Window
(Series 120)
17-0918.09
9.37 x 38OX Horizontal Rolling Window
(Series 120)
17-0918.09
10.74 x 38XO Horizontal Rolling Window
(Series 120)
17-0918.09
11.53 x 63Single Hung Window
(Series 110)
17-1018.08
12.74 x 63OX Horizontal Rolling Window
(Series 120)
17-0918.09
MRH 14'
Bedroom
BathRoom
LaundryRoom
Garage
Bedroom
Bedroom
BathRoom
KitchenLivingRoom
Den
DiningRoom
Property Information
Owner:Linda Minton
Address:2451 S FFA Road
Fort Pierce, FL 34945
Building Information
Wind Zone:160 MPH.
Exposure Category:C
Minimum Building Dimension:40 ft.
Mean Roof Height:14 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 End 37 81 7 31.9 -41.6
2 End 74 63 7 30.9 -39.7
3 End 74 63 7 30.9 -39.7
4 End 26 50 7 33.5 -44.8
5 End 74 63 7 30.9 -39.7
6 End 96 80 7 29.8 -37.5
7 End 37 63 7 32.4 -42.7
8 End 74 38 7 32.0 -41.9
9 End 37 38 7 33.5 -44.8
10 End 74 38 7 32.0 -41.9
11 End 53 63 7 31.6 -41.2
12 End 74 63 7 30.9 -39.7
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code.
Page 1 of 1