HomeMy WebLinkAboutPlans3
Egress4
2
1
0
Main Door
6
Egress
5
Egress
PAGE:
1
OF
1
PAGE DESCRIPTION:
Site Plan
DATE:
Jul 10, 2020
SCALE:
NOT TO SCALE
COPYRIGHT E-TEMPEST.COM
Re
g
i
n
a
M
u
r
r
a
y
12
1
R
i
o
m
a
r
C
o
u
r
t
Po
r
t
S
t
L
u
c
i
e
,
F
L
3
4
9
5
2
Opening Size
(W x H)
0. Omit
(Not Replacing)
1.96 x 63XOX Horizontal Rolling Window
(Series 120)
17-0918.09
2.33 x 43XO Horizontal Rolling Window
(Series 120)
17-0918.09
3.96 x 48XOX Horizontal Rolling Window
(Series 120)
17-0918.09
4.48 x 24OX Horizontal Rolling Window
(Series 120)
17-0918.09
5.80 x 48OX Horizontal Rolling Window
(Series 375)
18-1001.11
6.96 x 63XOX Horizontal Rolling Window
(Series 120)
17-0918.09
MRH 20'1st Floor
Garage
Living Room
BedroomBathRoom
Bedroom BathRoom
Bedroom
Kitchen DiningRoom Stairs
Property Information
Owner:Regina Murray
Address:121 Riomar Court
Port St Lucie, FL 34952
Building Information
Wind Zone:160 MPH.
Exposure Category:C
Minimum Building Dimension:30 ft.
Mean Roof Height:20 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 End 96 63 7 32.3 -41.0
2 End 33 43 7 35.6 -47.6
3 End 96 48 7 32.9 -42.2
4 End 48 24 7 35.6 -47.6
5 End 80 48 7 33.3 -43.1
6 End 96 63 7 32.3 -41.0
Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code.