Loading...
HomeMy WebLinkAboutPlans3 Egress4 2 1 0 Main Door 6 Egress 5 Egress PAGE: 1 OF 1 PAGE DESCRIPTION: Site Plan DATE: Jul 10, 2020 SCALE: NOT TO SCALE COPYRIGHT E-TEMPEST.COM Re g i n a M u r r a y 12 1 R i o m a r C o u r t Po r t S t L u c i e , F L 3 4 9 5 2 Opening Size (W x H) 0. Omit (Not Replacing) 1.96 x 63XOX Horizontal Rolling Window (Series 120) 17-0918.09 2.33 x 43XO Horizontal Rolling Window (Series 120) 17-0918.09 3.96 x 48XOX Horizontal Rolling Window (Series 120) 17-0918.09 4.48 x 24OX Horizontal Rolling Window (Series 120) 17-0918.09 5.80 x 48OX Horizontal Rolling Window (Series 375) 18-1001.11 6.96 x 63XOX Horizontal Rolling Window (Series 120) 17-0918.09 MRH 20'1st Floor Garage Living Room BedroomBathRoom Bedroom BathRoom Bedroom Kitchen DiningRoom Stairs Property Information Owner:Regina Murray Address:121 Riomar Court Port St Lucie, FL 34952 Building Information Wind Zone:160 MPH. Exposure Category:C Minimum Building Dimension:30 ft. Mean Roof Height:20 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 96 63 7 32.3 -41.0 2 End 33 43 7 35.6 -47.6 3 End 96 48 7 32.9 -42.2 4 End 48 24 7 35.6 -47.6 5 End 80 48 7 33.3 -43.1 6 End 96 63 7 32.3 -41.0 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1