HomeMy WebLinkAboutOC Rhino Underlayment14
BCIS Home Log In User Registration Hot Topics Submit Surcharge Siats & Facts Publications Contact Us BCIS Site Map Links Search
dbpr(L-go
Product Approval
USER: Public User
Product Aooroval Menu > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL15216-R7
Revision
2017
Approved
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43645
.(740) 321-6345
Greg. Keeler@owenscorning.com
Keeler Greg
Greg.Keeler@owenscorning.com
Greg Keeler
2790 Columbus Road
Granville, OH 43023
�]�Q) 321-6345
greg.keeler@owenscorning.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert Nieminen
PE -59166
Intertek Testing Services NA, Inc. - QA Entity
12/31/2020
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL15216 $Z COI 2924 U -COI NIEMINEN.odf
Standard
ASTM D1970 (tear)
ASTM D226 (physicals)
ASTM D4533 (tear)
ASTM D4798
Year
2015
2009
2015
2011
https://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGE...VVKJZlQRAdhy12u8kQGBluXH3UJw7iV8%2f6fWNGQlQ%3d%3d 5/13/20, 1007 AM
Page 1 of 2
TAS 117(B)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
02/12/2020
Date Validated
02/13/2020
Date Pending FBC Approval
02/14/2020
Date Approved
04/07/2020
Summary of Products
FL # Model, Number or Name Description
15216.1 RhinoRoof U20, ABC Pro Guard 20 Synthetic roof underlayments
and SRS TopShield TS20 Roof
Underlayments
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See ER Section 5 for Limits of Use.
1995
Installation Instructions
FL1521 _92_11_ZQ2Q_U _13_EIIYAL ER GLEN.
CORNING RHINOROOF FL15216-R7.Ddf
Verified By: Robert Nieminen PE -59166
Created by Independent Third Party: Yes
Evaluation Reports
FL1521_37_AE_2024_4Z-13-FINAL ER—QAEK
CORNING RHINOROOF_FL15216-R7.pdf
Created by Independent Third Party: Yes
imom
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 .1
The State of Florida is an AA/EEO employer. Cop n ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
n Cl � El
Credit Card
Safe
https:/iwww.floridabuilding.org/pr/pr app dtl.aspx?param=wGE... VVKJZ1QRAdhyl2u8kQGB1uXH3UJw7iV8%2f6fWNGQ1Q%3d%3d 5/13/20, 10:08 AM
Page 2 of 2
ENGINEER EVALUATE
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43659
(740) 321-6345
TEST
NEW I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
CONSULT CERTIFY
Evaluation Report 140510.02.12-118
FL15216-R7
Date of Issuance: 02/17/2012
Revision 8: 02/13/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
OF
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 02/13/2020. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02019 NEMO ETC, LLC
ONEMOletc.
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments, as
produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections
of the 61 Edition (2017) Florida Building Code through testing in accordance with applicable sections of the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
2. STANDARDS:
Section Properties Standard Year
1507.1.1, R905.1.1 Exception, Unrolling, Breaking Strength, Pliability ASTM D226 2009
1518.4
Product
Specification
Plant(s)
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D1970
2015
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D4533
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
TAS 110
Pull-through resistance
TAS 117(B)
1995
3. REFERENCES:
Product
Specification
Plant(s)
Entity
Examination
Reference
Date
ITS (TST1509)
Physical Properties
100539395COQ-006
10/27/2011
ITS (TST1509)
Physical Properties
100539395COQ-002
10/27/2011
ITS (TST1509)
Physical Properties
100539395COQ-006
03/14/2014
PRI (TST5878)
Physical Properties
OCF-330-02-01
09/20/2017
PRI (TST5878)
ASTM D1970; Tear strength (Qingdao)
OCF-330-02-02
10/03/2017
PRI (TST5878)
TAS 117(B); Pull-through
OCF-422-02-01
04/03/2018
PRI (TST5878)
ASTM D226, ASTM D4533 (Tear strength)
OCF-464-02-02
12/10/2019
PRI (TST5878)
Physicals Properties & AW (Silvassa)
OCF-394-02-07.4
01/06/2020
PRI (TST5878)
Accelerated Weathering (Qingdao)
OCF-464-02-02.2
01/06/2020
ITS (QUA1673)
Quality Control
Service Confirmation
0g9/30/2017
4
4.1
4.2
43
PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
RhinoRoof U20
FBC 1507.1.1 & R905.1.1
(Exception)
Qingdao, China
Silvassa, India
Multilayered polymer woven
coated synthetic roof underlayment
ABC Pro Guard 20
FBC 1507.1.1 & R905.1.1
(Exception)
Qingdao, China
Silvassa, India
Multilayered polymer woven
coated synthetic roof underlayment
SRS TopShield TS20 J
FBC 1507.1.1 & R905.1.1
(Exception)
Qingdao, China
Silvassa, India
Multilayered polymer woven
coated synthetic roof underlayment
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments may be used with any prepared
roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request
may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting
data for the prepared roof covering.
NEMO ETC, LLC Evaluation Report 140510.02.12-118
Certificate of Au#horization #32455 6'" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020
Page 2 of 4
f&4�
�0'%s
4: ,
MEMO I etc.
5.4 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Shingles
Tile
Wood Shakes & Slate or
Metal Shingles Simulated Slate
RhinoRoof U20
Yes
No
Yes Yes No
ABC Pro Guard 20
Yes
No
Yes Yes No
SRS TopShield TS20
Yes
No
Yes Yes No
5.5 Exposure Limitations:
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 shall not be left exposed for longer than 90 -days after
installation.
6. INSTALLATION:
6.1 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments shall be installed in accordance
with the manufacturer's published installation instructions subject to the Limitations set forth in Section 5 herein
and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application.
1 6.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20:
6.3.1 1 NON-HVHZ Jurisdictions:
6.3.1.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for
double -layer applications.
6.3.1.2 Fasteners:
For exposure up to maximum 24 hours, corrosion resistant fasteners may be 1 -inch roofing nails with a 3/8 -inch
diameter head, minimum 1 -inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps
(with the rough edge facing up). The use of staples is prohibited.
For exposure beyond 24 hours up to maximum 30 days, corrosion resistant fasteners shall b� minimum 1 -inch
diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up).
The use of staples is prohibited.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall
be required where the ultimate design wind speed, V„it, equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1 -inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the RhinoRoof U20, ABC Pro Guard 20 or SRS TopShield TS20
underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1
or R905.1.1.
6.3.1.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 4 -inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4 -inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.3.1.4 Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 12 -inches and side (horizontal) laps shall be minimum 22 -inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
NEMO ETC, LLC Evaluation Report 140510.02.12-118
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020
Page 3 of 4
ONEMOjetc-
Begin
by fastening a 22 -inch wide strip along the eaves. Place a full -width sheet over the starter, completely
overlapping the starter course. Continue upslope, maintaining minimum 22 -inch side (horizontal) laps, resulting in
a double -layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4 -inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.3.2 HVHZ Jurisdictions:
6.3.2.1 Shall be installed in a shingle fashion with minimum 4 -inch wide side (horizontal) laps and minimum 6 -inch wide
end laps.
6.3.2.2 Shall be fastened with FBC HVHZ approved corrosion resistant, 1-5/8" diameter tin -caps and 12 gauge 1.25" long
annular ring -shank nails (FBC 1517.5) spaced max. 6 -inch o.c. at all laps and 12 -inch o.c. at three (3) equally spaced
rows in the field of the sheet.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
H. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer
to Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY: .
Intertek Testing Services NA Inc. — ETL/Warnock Hersey— QUA1673; (604) 520-3321;
peter.gildenstern@intertek.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 140510.02.12-R8
Certificate of Autoorization #32455 6T" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020
Page 4 of 4