Loading...
HomeMy WebLinkAboutOC Rhino Underlayment14 BCIS Home Log In User Registration Hot Topics Submit Surcharge Siats & Facts Publications Contact Us BCIS Site Map Links Search dbpr(L-go Product Approval USER: Public User Product Aooroval Menu > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL15216-R7 Revision 2017 Approved Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43645 .(740) 321-6345 Greg. Keeler@owenscorning.com Keeler Greg Greg.Keeler@owenscorning.com Greg Keeler 2790 Columbus Road Granville, OH 43023 �]�Q) 321-6345 greg.keeler@owenscorning.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE -59166 Intertek Testing Services NA, Inc. - QA Entity 12/31/2020 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL15216 $Z COI 2924 U -COI NIEMINEN.odf Standard ASTM D1970 (tear) ASTM D226 (physicals) ASTM D4533 (tear) ASTM D4798 Year 2015 2009 2015 2011 https://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGE...VVKJZlQRAdhy12u8kQGBluXH3UJw7iV8%2f6fWNGQlQ%3d%3d 5/13/20, 1007 AM Page 1 of 2 TAS 117(B) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/12/2020 Date Validated 02/13/2020 Date Pending FBC Approval 02/14/2020 Date Approved 04/07/2020 Summary of Products FL # Model, Number or Name Description 15216.1 RhinoRoof U20, ABC Pro Guard 20 Synthetic roof underlayments and SRS TopShield TS20 Roof Underlayments Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See ER Section 5 for Limits of Use. 1995 Installation Instructions FL1521 _92_11_ZQ2Q_U _13_EIIYAL ER GLEN. CORNING RHINOROOF FL15216-R7.Ddf Verified By: Robert Nieminen PE -59166 Created by Independent Third Party: Yes Evaluation Reports FL1521_37_AE_2024_4Z-13-FINAL ER—QAEK CORNING RHINOROOF_FL15216-R7.pdf Created by Independent Third Party: Yes imom Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 .1 The State of Florida is an AA/EEO employer. Cop n ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: n Cl � El Credit Card Safe https:/iwww.floridabuilding.org/pr/pr app dtl.aspx?param=wGE... VVKJZ1QRAdhyl2u8kQGB1uXH3UJw7iV8%2f6fWNGQ1Q%3d%3d 5/13/20, 10:08 AM Page 2 of 2 ENGINEER EVALUATE Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 (740) 321-6345 TEST NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 CONSULT CERTIFY Evaluation Report 140510.02.12-118 FL15216-R7 Date of Issuance: 02/17/2012 Revision 8: 02/13/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 OF The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/13/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC, LLC ONEMOletc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections of the 61 Edition (2017) Florida Building Code through testing in accordance with applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Properties Standard Year 1507.1.1, R905.1.1 Exception, Unrolling, Breaking Strength, Pliability ASTM D226 2009 1518.4 Product Specification Plant(s) 1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, R905.1.1 Exception Tear Strength ASTM D4533 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull-through resistance TAS 117(B) 1995 3. REFERENCES: Product Specification Plant(s) Entity Examination Reference Date ITS (TST1509) Physical Properties 100539395COQ-006 10/27/2011 ITS (TST1509) Physical Properties 100539395COQ-002 10/27/2011 ITS (TST1509) Physical Properties 100539395COQ-006 03/14/2014 PRI (TST5878) Physical Properties OCF-330-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength (Qingdao) OCF-330-02-02 10/03/2017 PRI (TST5878) TAS 117(B); Pull-through OCF-422-02-01 04/03/2018 PRI (TST5878) ASTM D226, ASTM D4533 (Tear strength) OCF-464-02-02 12/10/2019 PRI (TST5878) Physicals Properties & AW (Silvassa) OCF-394-02-07.4 01/06/2020 PRI (TST5878) Accelerated Weathering (Qingdao) OCF-464-02-02.2 01/06/2020 ITS (QUA1673) Quality Control Service Confirmation 0g9/30/2017 4 4.1 4.2 43 PRODUCT DESCRIPTION: Product Specification Plant(s) Description RhinoRoof U20 FBC 1507.1.1 & R905.1.1 (Exception) Qingdao, China Silvassa, India Multilayered polymer woven coated synthetic roof underlayment ABC Pro Guard 20 FBC 1507.1.1 & R905.1.1 (Exception) Qingdao, China Silvassa, India Multilayered polymer woven coated synthetic roof underlayment SRS TopShield TS20 J FBC 1507.1.1 & R905.1.1 (Exception) Qingdao, China Silvassa, India Multilayered polymer woven coated synthetic roof underlayment S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC, LLC Evaluation Report 140510.02.12-118 Certificate of Au#horization #32455 6'" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020 Page 2 of 4 f&4� �0'%s 4: , MEMO I etc. 5.4 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Tile Wood Shakes & Slate or Metal Shingles Simulated Slate RhinoRoof U20 Yes No Yes Yes No ABC Pro Guard 20 Yes No Yes Yes No SRS TopShield TS20 Yes No Yes Yes No 5.5 Exposure Limitations: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 shall not be left exposed for longer than 90 -days after installation. 6. INSTALLATION: 6.1 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments shall be installed in accordance with the manufacturer's published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 1 6.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20: 6.3.1 1 NON-HVHZ Jurisdictions: 6.3.1.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for double -layer applications. 6.3.1.2 Fasteners: For exposure up to maximum 24 hours, corrosion resistant fasteners may be 1 -inch roofing nails with a 3/8 -inch diameter head, minimum 1 -inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up). The use of staples is prohibited. For exposure beyond 24 hours up to maximum 30 days, corrosion resistant fasteners shall b� minimum 1 -inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up). The use of staples is prohibited. Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall be required where the ultimate design wind speed, V„it, equals or exceeds 150 mph." Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1 -inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the RhinoRoof U20, ABC Pro Guard 20 or SRS TopShield TS20 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.1.3 Slopes of 4:12 or greater: End (vertical) laps shall be minimum 6 -inches and side (horizontal) laps shall be minimum 4 -inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4 -inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.1.4 Slopes of 2:12 to less than 4:12: End (vertical) laps shall be minimum 12 -inches and side (horizontal) laps shall be minimum 22 -inches. End (vertical) laps shall be offset from course to course not less than 6 feet. NEMO ETC, LLC Evaluation Report 140510.02.12-118 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020 Page 3 of 4 ONEMOjetc- Begin by fastening a 22 -inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 22 -inch side (horizontal) laps, resulting in a double -layer application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4 -inch o.c. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.2 HVHZ Jurisdictions: 6.3.2.1 Shall be installed in a shingle fashion with minimum 4 -inch wide side (horizontal) laps and minimum 6 -inch wide end laps. 6.3.2.2 Shall be fastened with FBC HVHZ approved corrosion resistant, 1-5/8" diameter tin -caps and 12 gauge 1.25" long annular ring -shank nails (FBC 1517.5) spaced max. 6 -inch o.c. at all laps and 12 -inch o.c. at three (3) equally spaced rows in the field of the sheet. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. H. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. 9. QUALITY ASSURANCE ENTITY: . Intertek Testing Services NA Inc. — ETL/Warnock Hersey— QUA1673; (604) 520-3321; peter.gildenstern@intertek.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 140510.02.12-R8 Certificate of Autoorization #32455 6T" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020 Page 4 of 4