Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KEY LARGO MODEL Builder Name: PACE 2000, INC. Street: 2351 S BROCKSMITH ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT STLUCIE , FL, Permit Number: Owner: ERNEST AND CAROLINE RODRIQUEZ Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or eAsting. New (From Plans) 9. Wall Types (2400.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a Concrete Block - Ext Insul, Exterior R=4.1 2154.70 ft2 b. Frame - Wood, Adjacent R=11.0 246.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this aworst case? No 10. Ceiling Types (2308.0 sgfQ Insulation Area a Roof Deck (Unvented) R=20.0 2308.00 t12 6. Conditioned floor area above grade (112) 2308 b. NIA R= ft2 Conditioned floor area below grade (112) 0 c. N/A R= ft2 11. Ducts R f12 7. Windows(409.0 sgft.) Description Area a. Sup: Attic, Ret: Attic,AH: Attic 6 175 a U-Factor: Sgl, U=0.56 132.00 ft2 SHGC: SHGC-0.24 b. U-Factor: Sgl, U=0.69 96.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.22 a Central Unit 41.0 SEER:16.00 c. U-Factor: Sgl, U=0.30 78.00 ft2 , SHGC: SHGC=0.28 13. Healing systems kBtu/hr Efficiency d. U-Factor: other (see details) 103.00 ft2 a Electric Strip Heat 27.0 COPA.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 5.202 ft. Area Weighted Average SHGC: 0.240 14. Hot water systems 8. Floor Types (2308.0 sgtL) Insulation Area a. Electric Cap: 50 gallons EF: 0.980 a Slab -On -Grade Edge Insulation R=0.0 2308.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Total Proposed Modified Loads: 76.94 Glass/Floor Area: 0.177 PASS Total Baseline Loads: 77.58 1 hereby certify that the plans and specifications covered by Review of the plans and IT STq� this calculation are in compliance with the Florida Energy specifications covered by this y , _ P O� Cade. calculation indicates compliance ; with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 10-18-19 this building will be inspected for compliance with Section 553.908 0 31 i I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Cc COD W6 OWNER/AGENT- - BUILDING OFFICIAL: DATE: 11 /19/19 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (13402.4.1.2). File Copy 10/17/2019 12:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1),- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KEY LARGO MODEL Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2308 Lot # Owner Name: ERNEST AND CAROLINE R Total Stories: 1 BlocklSubdivlsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: PACE 2000, INC. Rotate Angle: 0 Street: 2351 S BROCKSMITH Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 / 2.5 / Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2308 20827.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 322 2898 No 0 1 1 Yes Yes Yes 2 WIC 63 567 No 0 1 Yes Yes Yes 3 MASTER BATH 187 1683 No 0 1 Yes Yes Yes 4 TOILET 28 252 No 0 1 Yes Yes Yes 5 LINEN 12 110.3 No 0 1 No Yes Yes 6 FOYER 56 515.2 No 0 1 Yes Yes Yes 7 OFFICE 128 1177.6 No 0 1 Yes Yes Yes 8 LIVING ROOM 285 2565 No 0 1 Yes Yes Yes 9 KITCHEN 255 2302.6 Yes 0 1 Yes Yes Yes 10 HALLWAY 42 378 No 0 1 No Yes Yes 11 UTILITYROOM 68 612 No 0 1 No Yes Yes 12 CLST 2 14 126 No 0 1 No Yes Yes 13 BEDROOM 2 153 1377 No 0 1 1 Yes Yes Yes 14 BATH 2 68 612 No 0 1 Yes Yes Yes 15 CLST 3 16 144 No 0 1 Yes Yes Yes 16 BEDROOM 3 132 1188 No 0 1 1 Yes Yes Yes 17 FAMILY ROOM 250 2250 No 0 1 Yes Yes Yes 18 NOOK 171 1539 No 0 1 Yes Yes Yes 19 CLST 4 36 No 0 1 No Yes Yes 20 CABANA 44 404.4 No 0 1 Yes Yes Yes 21 OFFICE CLST 10 90 No 0 0 1 Yes Yes Yes 10/17/201912:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPART FLOORS >t Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 29 It 0 322 ft2 0 1 0 2Siab-On-Grade Edge Insulation WIC 7 ft 0 63 ft2 __ 0 1 0 3SIab-On-Grade Edge Insulation MASTER BATH 28.4 ft ' 0 187 ft2 0 1 0 4 Slab -On -Grade Edge Insulation TOILET 6 it 0 28 ft2 __-- 0 1 0 5SIab-On-Grade Edge Insulation LINEN 1 ft 0 12 ft2 ____ 0 1 0 6SIab-On-Grade Edge Insulation FOYER 7 ft 0 56 ft2. 0 1 0 7 Slab -On Grade Edge Insulation OFFICE 13 ft 0 128 ft2 0 1 0 SSlab-On-Grade Edge Insulation LIVING ROOM 15ft 0 285ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulation KITCHEN 2it -'.` 0 .255fn ____ 0 1 0 10Slab-On-Grade Edge Insulation HALLWAY 1 ft _ 0 42ft2 ___ 0 1 0 11SIab-OnGrade Edge Insulation UT1U' Y ROOM 1 it - 0 68 ft2 0 1 0 72SIab-On-Grade Edge Insulation CLST 2 1 ft 0 14 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulation BEDROOM 2 11 ft 0 153 ft2 ____ 0 1 0 14SIab-On-Grade Edge Insulation BATH 2 5 ft 0 68 ft2 0 1 0 15SIab-On-Grade Edge Insulation CLST 3 2 it 0 16 IF ___ 0 1 0 76SIab-On-Grade Edge Insulation BEDROOM 11 ft 0 132 ft2 ___ 0 1 0 17SIab-On-Grade Edge Insulation FAMILY ROOM 45 ft 0 250 ft2 ___- 0 1 0 18SIab-On-Grade Edge Insulation NOOK 21 ft 0 171 ft2 ___ 0 1 0 19SIab-On-Grade Edge Insulation CLST 1 it 0 4 f12 ____ 0 1 0 20SIab-On-Grade Edge Insulation CABANA 21 ft 0 44 ft2 ____ 0 1 0 21SIab-On-Grade Edge insulation OFFICE CLST 2 ft ., 0 10 ft2 ____ 0 1 0 ROOF Roof Gable Roof Rad Solar SA Em!U Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2581 ft2 0ft2 Light N 0.4 No 0.9 No 20 26.6 ATTIC k Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Unvented 0 2308IF N N 10117=19 12:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes20;17. FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING >k Ceiling Type Space R-Value. - Ins Type Area Framing Free Truss Type 1 Under Attic(Unvented) MASTER BEDRO 0 . Blown 322ft2 0.1 Wood 2 Under Attic (Unvented) ,. WIC -, ,0 _ Blown 63 ft2 0.1 Wood 3 Under Attic (Unvented) MASTER BATH %0 ' Blown 187 ft2 0.1 Wood 4 Under Attic (Unvented) TOILET .0 Blown 0.1 Wood 5 Under Attic (Unvented) LINEN 0 Blown 12 ft2 0.1 Wood 6 Under Attic (Unvented) FOYER 0 Blown 56 f12 0.1 Wood 7 Under Attic (Unvented) OFFICE 0.. Blown .126 ft2 0.1 Wood 8 Under Attic (Unvented) LIVING ROOM 0 Blown 285 IF 0.1 Wood 9 Under Attic (Unvented) KITCHEN 0 , Blown 255 ft2 0.1 Wood 70 Under Attic (Unvented) HALLWAY 0 Blown 42ft2 0.1 Wood 11 Under Attic (Unvented) UTILITYROOM 0 Blown 68 ft2 0.1 Wood 12 Under Attic (Unvented) CLST 2 0 Blown 14 ft2 0.1 Wood 13 Under Attic (Unvemed) ., _BEDROOM2 _ = 0 Blown 1531? 0.1 Wood 14 Under Attic (Unvented) BATH ',q,±�, .- Blown 68 IF 0.1 Wood 15 Under Attic (Unvented) CLST 3 ' '0 - ^ '-' Blown 16 IF 0.1 Wood 16 Under Attic (Unvented) BEDROOM3 0 Blown 132 IF 0.1 Wood 17 Under Attic(Unvented) FAMILYROOM 0 Blown 250 ftz 0.1 Wood 18 Under Attic (Unvented) NOOK 0 . "" Blown 171 ft2 0.1 Wood 19 Under Attic (Unvented) CLST 0 Blown 4 f12 . 0.1 Wood 20 Under Attic (Unvented) CABANA 0 Blown 44IF 0.1 Wood 21 Under Attic(Unvented) OFFICECLST 0 Blown 10 ftz 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block- Ext InsdMASTER BE 4.1 5 0 10 4 51.7 fn 0 0 0.4 0 2 ,S Exterior Concrete Block- Ext InstMASTER BE 4.1 : 17 0 10 4 175.7 ftz 0 0 0.4 0 3 W Exterior Concrete Block- Ext InstMASTER BE 4.1 7 0 10 4 72.3 ft2 0 0 0.4 0 _ 4 S Exterior Concrete Black -Ext Insul . WIC 4.1 ..,`7 0 9 4 65.31? 0 0 0.4 0 5 N Exterior Concrete Block - Ext InsNASTER BA 4.1 , „1 0 9 4 9.3 ft2 0 0 0.4 0 6 NE Exterior Concrete Block- Ext InstMASTER BA 4.1 ,. -,4-,- 3 9 4 39.7 ft= 0 0 0.4 0 7 E Exterior Concrete Block- Ext InsXASTER BA 4.1 •. ' 8 0 9 4 74.7 fri 0 0 0.4 0 8 BE Exterior Concrete Block- Ext InstMASTER BA 4.1 :• 4 3 9 4 39.7 W 0 0 0.4 0 _ 9 S Exterior Concrete Block - Ext InsdMASTER BA 4.1 "11 0 9 4 102.7 ft2 0 0 0.4 0 10 N Exterior Concrete Block - Ext Insul TOILET 4.1 2 0 9 4 18.7 ft= 0 0 0.4 0 11 E Exterior Concrete Block - Ext Insul TOILET 4.1 4 0 9 4 37.3IF 0 0 0.4 0 12 E Exterior Concrete Block- Ext Insul FOYER 4.1 7 0 10 0 70.0 ft2 0 0 0.4 0 _ 13 E Exterior Concrete Block- Ext Insul OFFICE 4.1 11 0 10 0 110.0 ft2 - 0 0 0.4 0 14, S Exterior Concrete Block- Ext Insul OFFICE 4.1 "2 0 10 0 20.01? 0 0 0.4 0 _15 N Garage Frame - Wood OFFICE CLS 11 5, 0 10 .G 50.0 ft2 0 0.1 0.4 0 16 W Exterior Concrete Block- ExtInsd11VING ROO 4.1 - . 15 0 11 '0 165.0 frz 0 0 0.4 0 17 S Exterior Concrete Block - Ext Insul KITCHEN 4.1 2 0 10 0 20.0 ftz 0 0 0.4 0 _18 E Garage Frame - Wood UTILITYROO 11 5 0 9 4 56.0ft2 0 0.1 0.4 0 _19 E Garage Frame - Wood CLST2 11 2 0 9 4 16.7ft' 0 0.1 0.4 0 10117201912:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R4(M-9017 INPIIT SIIMMARY'CI4FrICI LCT RFPART WALLS Adjacent Space Cavity le Width Pt In .:HeigR-VA11 Ft Iht Sheathing Framing Solar Below _20 N Exterior Concrete Block -Ext lnsiBEDROOM2 4.1 11 0 9 4- 102.7 ft2 0 0 0.4 0 _21 E Garage Frame - Wood BEDROOM2 11 13 0 9 4 121.3 ft2 0 0.1 0.4 0 22 N Exterior Concrete Block- Ext Insul BATH 2 4.1 5 0 9 4 46.7 ft2 0 0 0.4 0 _23 N Exterior Concrete Block -Ext Insul CLST3 4.1 2 0 9 4 18.7fV 0 0 0.4 0 24 N Exterior Concrete Block - Ext InsMEDROOM3 4.1 11 0 9 4 102.7ft' 0 0 0.4 0 _25 N Exterior Concrete Block- Ext lnsddAMILYROO 4.1 16 0 9 4 149.3ft2 0 0 0.4 0 26 S Exterior Concrete Block- Ext Ins61AMl LY ROO 4.1 11 0 9 4 102.7ft2 0 0 0.4 0 27 W Exterior Concrete Block - Ext Ins51AMILY ROO 4.1 -18 0 9 4 168.0 ft2 0 0 0.4 0 _28 S Exterior Concrete Block- Ext Insul NOOK 4.1 9 0 9 4 84.0112 0 0 0.4 0 _ 29 W Exterior Concrete Block- Ext Insul NOOK 4.1 12 0 9 4 112.0 ft2 0 0 0.4 0 30 N Exterior Concrete Block- Ext Insul CABANA 4.1 : 7 0 9 4 65.3 112 0 0 0.4 0 31 S Exterior Concrete Block- Ext Insul CABANA 4,1, .. ;� 7, 0 9 4 65.3 ft2 0 0 0.4 0 _32 W Exterior Concrete -Block- Ent Insul CABANA 471 " -'7-" 0 9 4 65.3 ft? 0 0 0.4 0 WINDOWS ' Orientation shown is the entered', Proposed orientation. Wall, Overhang V a# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Vinyl Low-E Single Yes 0.56 .0.24 N 20.0 ft2 1 ft 8 in 0 ft 7 in None None 2 W 3 Vinyl Low-E Single Yes 0.56 0.24 , N 20.0 ft2 1 ft 8 in 0 ft 7 in None None 3 NE 6 Vinyl Low-E Single Yes 0.39 0.25 N 5.0 ft2 1 ft 8 in 0 ft 7 in Drapesiblinds Exterior 5 4 E 7 Vinyl Low-E Single Yes 0.39 0.25 N 10.0 112 1 ft 81n 0 ft 7 in Drapes/blinds Exterior 5 5 BE 8 Vinyl Low-E Single Yes, 0.39 0.25 N 5.0 ft2 1 ft 8 in 0 ft 71n Drapes/blinds Exterior 5 6 S 9 Vinyl Low-E Single Yes 0.56 0.24 N 12.0 ft2 1 ft 8 in 0 it 7 in Drapesiblinds Exterior 5 7 E 12 Vinyl Low-E Single Yes 0.3 0.28 N 40.0 ft2 1 ft 8 in 0 ft 7 in None None 8 E 13 Vinyl Low-E Single Yes 0.56 0.24 N 36.0 ft2 1 It 8 in 0 ft 7 in None None 9 W 16 Vinyl Low-E Single Yes 0.69 0.22 N 96.0 W 14 ft 0 in 0 ft 7 in Drapesiblinds Exterior 5 10 N 20 Vinyl Low-E Single Yes 0.57 0.22 N 15.0 ft2 1 ft 8 in 0 ft 7 in None None 11 N 22 Vinyl Low-E Single Yes 0.99- 0:25 ' N 8.0 fP 1 ft 8 in 0 ft 7 in None None 12 N 24 Vinyl Low-E Single Yes 0.57 • 0.22 N 15.0 ft2 1 ft 81n 0 ft 7 in None None 13 N 25 Vinyl Low-E Single Yes 0.57 0.22, - N 15.0 ft2 1 ft 81n 0 It 7 in Drapesiblinds Exterior 1 14 - W 27 Vinyl Lav-E,Single Yes 0.56 '" 0.24. ,N -:'"24:0;ft?:.,,.1 ft 8 in .0ft7in Drapes/blinds Exterior 15 S 28 Vinyl Law-E Single Yes 0.56 0.24 N 20.0 ft2 8 ft 0 in 0 ft 7 in Drapesiblinds Exterior 1 16 S 28 Vinyl Low-E Single Yes 0.3 0.28 N 21.3 ft2 8 ft 0 in 0 it 71n Drapesiblinds Exterior 1 17 W 29 Vinyl Lev-E Single Yes 0.57 022 N 30.0 ft2 1 ft 8 in 0 ft 7 in Drapes/blinds Exterior 1 18 N 30 Vinyl Low-E Single Yes 0.3 0.28 N 16.7 ft2 1 ft 8 in 0 ft 7 in None None 10/17)201912:14 PM EnergyGaugela USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHFCKI LGT RFPnPT GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. WaII Height Exposed Wall Insulation 1 462 ft2 462 ft' .v, 26,ft; :,. 8ft 11 INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 1 Wholehouse Proposed ACH(50) .000401 2429.8 133.39 250.87 .1459 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtwhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 41 kBtwhr 1230 elm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF " "" "Cap Use SetPnt Conservation 1 Electric None Garage 0.98 ,; .�' ' 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model 9- Collector Model # Area Volume FEF None None q ' , �, . " ft2 DUCTS V # --- Supply---- Location R-Value Area ---- Return --- - ' _ Air CFM 25 CFN25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 175 ffz Attic 18 ft2 Default Leakage "' Atic' ' (Defauft) c(Default) c 1 1 10/17201912:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes20413C 6th Edition (2017) Compliant Software Page 6 of 7 TEMPERATURES Programable��xThermostat: C[[eilling Fans: Hang :XJan]]N J� Feb[`X]J Feb jMar] MaY [[XJ] Jun 4X]J Jul [[X]] Aug 4X]J �nl jjOct OctOctt Nov[X]J Dec Venting l 1 Jan l 1 Feb lXl Mar lxl Pr f 1 , l; l Jun ` l 1 Jul l 1 Aug l 1 SSepe Sep Nov l 1 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 .5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 '" 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78, 78 78' 78 80 80 80 80 PM 80 80 80 80 78 `• 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68, 68 68 68 68 68 Heaffng(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 MASS, Mass Type Area :Thickness-• .FumitureFraction Space Default(8 lbs/sq.ft. 0ft2 •^_.0It 0.3 MASTERBEDR00 Defau@(8 lbs/sq.ft. ft2 It, 0.3 WIC Default(8 lbs/sq.ft. ft2 it 0.3 MASTER BATH Default(81bs/sq.ft. - ft2 ft 0.3 TOILET Default(8 lbs/sq.ft. 'ft2 ft! _ 0.3 LINEN DefauH(81bs/sq.ft. 112 ft 0.3 FOYER Default(8lbs/sq.ft. IF _ Its ' 0.3 OFFICE Default(8 lbs/sq.ft. ft2 ft• 0.3 LIVING ROOM Default(8 lbs/sq.ft. ft2 ft �. � 0.3 KITCHEN Default(81bs/sq.ft. I? ft „'.0.3 HALLWAY - Default(Blbs/sq.ft. ft2 It ' • 0.3 UTILITY ROOM Default(8 lbs/sq.ft. f12 it 0.3 CLST2 Default(81bs/sq.ft. ft2 it%^ 0.3 BEDROOM2 Defauft(8lbs/sq.ft. f12 If 0.3 BATH 2 Default(8 lbs/sq.ft. fr2 ft.:•`+, •- - 0.3 CLST3 Defautt(8 lbs/sq.ft. ft2 It 0.3 BEDROOM3 Default(81bs/sq.ft. IF It 0.3 FAMILYROOM Default(8 lbs/sq.ft. ft2 It 0.3 NOOK Default(8lbs(sq.ft. - ft2 - It 0.3 CLST Default(8lbs/sq.ft. ft2 It;. 0.3 CABANA rldmdlnl IFc/m F n ft ., n ff - n 9 !'1FFIRF CI CT n 10/172019 12:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts 2. Single-family or multiple -family 2. Single-family b) Return ducts R�Q c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 41. a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2308 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-tactor:(weighted average) 7a. 0.531 b) Solar Heat Gain Coefficient (SHGC) , 7b. 0.240 14. Heating system: Capacity 27.0 C) Area 7c. 409.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights - " "' c) Electric resistance COP 1.0 a) U-tactor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 81b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: ' a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water Pealing system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) tOBi. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No C) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit I) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code; Energy Conservation, if not DEFAULT. ('certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. ' Builder Signature: Date: 11 /19/19 Address of New Home: 2351 S BROCKSMITH ROAD City/FL Zip: PORT ST LUCIE FL 10/172019 12:15:30 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1