HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KEY LARGO MODEL
Builder Name: PACE 2000, INC.
Street: 2351 S BROCKSMITH ROAD
Permit Office: ST LUCIE COUNTY
City, State, Zip: PORT STLUCIE , FL,
Permit Number:
Owner: ERNEST AND CAROLINE RODRIQUEZ
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or eAsting. New (From Plans)
9. Wall Types (2400.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a Concrete Block - Ext Insul, Exterior
R=4.1 2154.70 ft2
b. Frame - Wood, Adjacent
R=11.0 246.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this aworst case? No
10. Ceiling Types (2308.0 sgfQ
Insulation Area
a Roof Deck (Unvented)
R=20.0 2308.00 t12
6. Conditioned floor area above grade (112) 2308
b. NIA
R= ft2
Conditioned floor area below grade (112) 0
c. N/A
R= ft2
11. Ducts
R f12
7. Windows(409.0 sgft.) Description Area
a. Sup: Attic, Ret: Attic,AH: Attic
6 175
a U-Factor: Sgl, U=0.56 132.00 ft2
SHGC: SHGC-0.24
b. U-Factor: Sgl, U=0.69 96.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a Central Unit
41.0 SEER:16.00
c. U-Factor: Sgl, U=0.30 78.00 ft2
,
SHGC: SHGC=0.28
13. Healing systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 103.00 ft2
a Electric Strip Heat
27.0 COPA.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 5.202 ft.
Area Weighted Average SHGC: 0.240
14. Hot water systems
8. Floor Types (2308.0 sgtL) Insulation Area
a. Electric
Cap: 50 gallons
EF: 0.980
a Slab -On -Grade Edge Insulation R=0.0 2308.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 76.94
Glass/Floor Area: 0.177
PASS
Total Baseline Loads: 77.58
1 hereby certify that the plans and specifications covered by
Review of the plans and
IT STq�
this calculation are in compliance with the Florida Energy
specifications covered by this
y , _ P O�
Cade.
calculation indicates compliance
;
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: 10-18-19
this building will be inspected for
compliance with Section 553.908
0 31 i
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Cc
COD W6
OWNER/AGENT- -
BUILDING OFFICIAL:
DATE: 11 /19/19
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (13402.4.1.2).
File Copy
10/17/2019 12:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1),- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
KEY LARGO MODEL
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2308
Lot #
Owner Name:
ERNEST AND CAROLINE
R
Total Stories:
1
BlocklSubdivlsion:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
PACE 2000, INC.
Rotate Angle:
0
Street:
2351 S BROCKSMITH
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
PORT ST LUCIE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Int Design Temp
Heating
Design
Daily Temp
V Design Location
TMY Site
97.5 /
2.5 /
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2308
20827.1
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
MASTER BEDROO
322
2898 No
0
1
1
Yes
Yes
Yes
2
WIC
63
567 No
0
1
Yes
Yes
Yes
3
MASTER BATH
187
1683 No
0
1
Yes
Yes
Yes
4
TOILET
28
252 No
0
1
Yes
Yes
Yes
5
LINEN
12
110.3 No
0
1
No
Yes
Yes
6
FOYER
56
515.2 No
0
1
Yes
Yes
Yes
7
OFFICE
128
1177.6 No
0
1
Yes
Yes
Yes
8
LIVING ROOM
285
2565 No
0
1
Yes
Yes
Yes
9
KITCHEN
255
2302.6 Yes
0
1
Yes
Yes
Yes
10
HALLWAY
42
378 No
0
1
No
Yes
Yes
11
UTILITYROOM
68
612 No
0
1
No
Yes
Yes
12
CLST 2
14
126 No
0
1
No
Yes
Yes
13
BEDROOM 2
153
1377 No
0
1
1
Yes
Yes
Yes
14
BATH 2
68
612 No
0
1
Yes
Yes
Yes
15
CLST 3
16
144 No
0
1
Yes
Yes
Yes
16
BEDROOM 3
132
1188 No
0
1
1
Yes
Yes
Yes
17
FAMILY ROOM
250
2250 No
0
1
Yes
Yes
Yes
18
NOOK
171
1539 No
0
1
Yes
Yes
Yes
19
CLST
4
36 No
0
1
No
Yes
Yes
20
CABANA
44
404.4 No
0
1
Yes
Yes
Yes
21
OFFICE CLST
10
90 No
0
0
1
Yes
Yes
Yes
10/17/201912:14 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPART
FLOORS
>t Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
29 It
0
322 ft2
0
1 0
2Siab-On-Grade Edge Insulation
WIC
7 ft
0
63 ft2
__
0
1 0
3SIab-On-Grade Edge Insulation
MASTER BATH
28.4 ft
'
0
187 ft2
0
1 0
4 Slab -On -Grade Edge Insulation
TOILET
6 it
0
28 ft2
__--
0
1 0
5SIab-On-Grade Edge Insulation
LINEN
1 ft
0
12 ft2
____
0
1 0
6SIab-On-Grade Edge Insulation
FOYER
7 ft
0
56 ft2.
0
1 0
7 Slab -On Grade Edge Insulation
OFFICE
13 ft
0
128 ft2
0
1 0
SSlab-On-Grade Edge Insulation
LIVING ROOM
15ft
0
285ft2
____
0
1 0
9 Slab -On -Grade Edge Insulation
KITCHEN
2it
-'.`
0
.255fn
____
0
1 0
10Slab-On-Grade Edge Insulation
HALLWAY
1 ft
_
0
42ft2
___
0
1 0
11SIab-OnGrade Edge Insulation
UT1U' Y ROOM
1 it
-
0
68 ft2
0
1 0
72SIab-On-Grade Edge Insulation
CLST 2
1 ft
0
14 ft2
____
0
1 0
13SIab-On-Grade Edge Insulation
BEDROOM 2
11 ft
0
153 ft2
____
0
1 0
14SIab-On-Grade Edge Insulation
BATH 2
5 ft
0
68 ft2
0
1 0
15SIab-On-Grade Edge Insulation
CLST 3
2 it
0
16 IF
___
0
1 0
76SIab-On-Grade Edge Insulation
BEDROOM
11 ft
0
132 ft2
___
0
1 0
17SIab-On-Grade Edge Insulation
FAMILY ROOM
45 ft
0
250 ft2
___-
0
1 0
18SIab-On-Grade Edge Insulation
NOOK
21 ft
0
171 ft2
___
0
1 0
19SIab-On-Grade Edge Insulation
CLST
1 it
0
4 f12
____
0
1 0
20SIab-On-Grade Edge Insulation
CABANA
21 ft
0
44 ft2
____
0
1 0
21SIab-On-Grade Edge insulation
OFFICE CLST
2 ft
.,
0
10 ft2
____
0
1 0
ROOF
Roof
Gable
Roof
Rad
Solar SA Em!U
Emitt
Deck Pitch
V
# Type Materials Area
Area
Color
Barr
Absor. Tested
Tested
Insul. (deg)
1 Hip
Metal 2581 ft2
0ft2
Light
N
0.4 No 0.9
No
20 26.6
ATTIC
k Type
Ventilation
Vent Ratio (1 in)
Area
FIBS IRCC
1 Full attic
Unvented
0
2308IF
N N
10117=19 12:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes20;17. FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
>k
Ceiling Type Space
R-Value. -
Ins Type
Area
Framing Free
Truss Type
1
Under Attic(Unvented) MASTER BEDRO
0
.
Blown
322ft2
0.1
Wood
2
Under Attic (Unvented) ,. WIC -,
,0
_
Blown
63 ft2
0.1
Wood
3
Under Attic (Unvented) MASTER BATH
%0
'
Blown
187 ft2
0.1
Wood
4
Under Attic (Unvented) TOILET
.0
Blown
0.1
Wood
5
Under Attic (Unvented) LINEN
0
Blown
12 ft2
0.1
Wood
6
Under Attic (Unvented) FOYER
0
Blown
56 f12
0.1
Wood
7
Under Attic (Unvented) OFFICE
0..
Blown
.126
ft2
0.1
Wood
8
Under Attic (Unvented) LIVING ROOM
0
Blown
285 IF
0.1
Wood
9
Under Attic (Unvented) KITCHEN
0
,
Blown
255 ft2
0.1
Wood
70
Under Attic (Unvented) HALLWAY
0
Blown
42ft2
0.1
Wood
11
Under Attic (Unvented) UTILITYROOM
0
Blown
68 ft2
0.1
Wood
12
Under Attic (Unvented) CLST 2
0
Blown
14 ft2
0.1
Wood
13
Under Attic (Unvemed) ., _BEDROOM2
_ = 0
Blown
1531?
0.1
Wood
14
Under Attic (Unvented) BATH
',q,±�,
.-
Blown
68 IF
0.1
Wood
15
Under Attic (Unvented) CLST 3
' '0
- ^ '-'
Blown
16 IF
0.1
Wood
16
Under Attic (Unvented) BEDROOM3
0
Blown
132 IF
0.1
Wood
17
Under Attic(Unvented) FAMILYROOM
0
Blown
250 ftz
0.1
Wood
18
Under Attic (Unvented) NOOK
0
. ""
Blown
171 ft2
0.1
Wood
19
Under Attic (Unvented) CLST
0
Blown
4 f12 .
0.1
Wood
20
Under Attic (Unvented) CABANA
0
Blown
44IF
0.1
Wood
21
Under Attic(Unvented) OFFICECLST
0
Blown
10 ftz
0.11
Wood
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing Solar
Below
1
N
Exterior Concrete Block- Ext InsdMASTER BE
4.1
5
0 10
4
51.7 fn
0
0
0.4
0
2
,S
Exterior Concrete Block- Ext InstMASTER BE
4.1 :
17
0 10
4
175.7 ftz
0
0
0.4
0
3
W
Exterior Concrete Block- Ext InstMASTER BE
4.1
7
0 10
4
72.3 ft2
0
0
0.4
0
_ 4
S
Exterior Concrete Black -Ext Insul . WIC
4.1
..,`7
0 9
4
65.31?
0
0
0.4
0
5
N
Exterior Concrete Block - Ext InsNASTER BA
4.1 ,
„1
0 9
4
9.3 ft2
0
0
0.4
0
6
NE
Exterior Concrete Block- Ext InstMASTER BA
4.1 ,.
-,4-,-
3 9
4
39.7 ft=
0
0
0.4
0
7
E
Exterior Concrete Block- Ext InsXASTER BA
4.1 •.
' 8
0 9
4
74.7 fri
0
0
0.4
0
8
BE
Exterior Concrete Block- Ext InstMASTER BA
4.1 :•
4
3 9
4
39.7 W
0
0
0.4
0
_ 9
S
Exterior Concrete Block - Ext InsdMASTER BA
4.1
"11
0 9
4
102.7 ft2
0
0
0.4
0
10
N
Exterior Concrete Block - Ext Insul TOILET
4.1
2
0 9
4
18.7 ft=
0
0
0.4
0
11
E
Exterior Concrete Block - Ext Insul TOILET
4.1
4
0 9
4
37.3IF
0
0
0.4
0
12
E
Exterior Concrete Block- Ext Insul FOYER
4.1
7
0 10
0
70.0 ft2
0
0
0.4
0
_ 13
E
Exterior Concrete Block- Ext Insul OFFICE
4.1
11
0 10
0
110.0 ft2 -
0
0
0.4
0
14,
S
Exterior Concrete Block- Ext Insul OFFICE
4.1
"2
0 10
0
20.01?
0
0
0.4
0
_15
N
Garage Frame - Wood OFFICE CLS
11
5,
0 10 .G
50.0 ft2
0
0.1
0.4
0
16
W
Exterior Concrete Block- ExtInsd11VING ROO
4.1
- . 15
0 11
'0
165.0 frz
0
0
0.4
0
17
S
Exterior Concrete Block - Ext Insul KITCHEN
4.1
2
0 10
0
20.0 ftz
0
0
0.4
0
_18
E
Garage Frame - Wood UTILITYROO
11
5
0 9
4
56.0ft2
0
0.1
0.4
0
_19
E
Garage Frame - Wood CLST2
11
2
0 9
4
16.7ft'
0
0.1
0.4
0
10117201912:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R4(M-9017 INPIIT SIIMMARY'CI4FrICI LCT RFPART
WALLS
Adjacent Space
Cavity
le
Width
Pt In
.:HeigR-VA11
Ft Iht
Sheathing Framing Solar
Below
_20
N
Exterior
Concrete Block -Ext lnsiBEDROOM2
4.1
11
0
9 4-
102.7 ft2
0
0 0.4
0
_21
E
Garage
Frame - Wood BEDROOM2
11
13
0
9 4
121.3 ft2
0
0.1 0.4
0
22
N
Exterior
Concrete Block- Ext Insul BATH 2
4.1
5
0
9 4
46.7 ft2
0
0 0.4
0
_23
N
Exterior
Concrete Block -Ext Insul CLST3
4.1
2
0
9 4
18.7fV
0
0 0.4
0
24
N
Exterior
Concrete Block - Ext InsMEDROOM3
4.1
11
0
9 4
102.7ft'
0
0 0.4
0
_25
N
Exterior
Concrete Block- Ext lnsddAMILYROO
4.1
16
0
9 4
149.3ft2
0
0 0.4
0
26
S
Exterior
Concrete Block- Ext Ins61AMl LY ROO
4.1
11
0
9 4
102.7ft2
0
0 0.4
0
27
W
Exterior
Concrete Block - Ext Ins51AMILY ROO
4.1
-18
0
9 4
168.0 ft2
0
0 0.4
0
_28
S
Exterior
Concrete Block- Ext Insul NOOK
4.1
9
0
9 4
84.0112
0
0 0.4
0
_ 29
W
Exterior
Concrete Block- Ext Insul NOOK
4.1
12
0
9 4
112.0 ft2
0
0 0.4
0
30
N
Exterior
Concrete Block- Ext Insul CABANA
4.1
: 7
0
9 4
65.3 112
0
0 0.4
0
31
S
Exterior
Concrete Block- Ext Insul CABANA
4,1, ..
;� 7,
0
9 4
65.3 ft2
0
0 0.4
0
_32
W
Exterior
Concrete -Block- Ent Insul CABANA
471 "
-'7-"
0
9 4
65.3 ft?
0
0 0.4
0
WINDOWS '
Orientation shown is the entered', Proposed
orientation.
Wall,
Overhang
V
a#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S
2
Vinyl Low-E Single Yes
0.56
.0.24
N
20.0 ft2
1 ft 8 in
0 ft 7 in
None
None
2
W
3
Vinyl Low-E Single Yes
0.56
0.24
, N
20.0 ft2
1 ft 8 in
0 ft 7 in
None
None
3
NE 6
Vinyl Low-E Single Yes
0.39
0.25
N
5.0 ft2
1 ft 8 in
0 ft 7 in
Drapesiblinds
Exterior 5
4
E
7
Vinyl Low-E Single Yes
0.39
0.25
N
10.0 112
1 ft 81n
0 ft 7 in
Drapes/blinds
Exterior 5
5
BE
8
Vinyl Low-E Single Yes,
0.39
0.25
N
5.0 ft2
1 ft 8 in
0 ft 71n
Drapes/blinds
Exterior 5
6
S
9
Vinyl Low-E Single Yes
0.56
0.24
N
12.0 ft2
1 ft 8 in
0 it 7 in
Drapesiblinds
Exterior 5
7
E
12
Vinyl Low-E Single Yes
0.3
0.28
N
40.0 ft2
1 ft 8 in
0 ft 7 in
None
None
8
E
13
Vinyl Low-E Single Yes
0.56
0.24
N
36.0 ft2
1 It 8 in
0 ft 7 in
None
None
9
W
16
Vinyl Low-E Single Yes
0.69
0.22
N
96.0 W
14 ft 0 in
0 ft 7 in
Drapesiblinds
Exterior 5
10
N
20
Vinyl Low-E Single Yes
0.57
0.22
N
15.0 ft2
1 ft 8 in
0 ft 7 in
None
None
11
N
22
Vinyl Low-E Single Yes
0.99-
0:25 '
N
8.0 fP
1 ft 8 in
0 ft 7 in
None
None
12
N
24
Vinyl Low-E Single Yes
0.57
• 0.22
N
15.0 ft2
1 ft 81n
0 ft 7 in
None
None
13
N
25
Vinyl Low-E Single Yes
0.57
0.22, -
N
15.0 ft2
1 ft 81n
0 It 7 in
Drapesiblinds
Exterior 1
14 -
W
27
Vinyl Lav-E,Single Yes
0.56 '"
0.24.
,N
-:'"24:0;ft?:.,,.1
ft 8 in
.0ft7in
Drapes/blinds
Exterior
15
S
28
Vinyl Law-E Single Yes
0.56
0.24
N
20.0 ft2
8 ft 0 in
0 ft 7 in
Drapesiblinds
Exterior 1
16
S
28
Vinyl Low-E Single Yes
0.3
0.28
N
21.3 ft2
8 ft 0 in
0 it 71n
Drapesiblinds
Exterior 1
17
W
29
Vinyl Lev-E Single Yes
0.57
022
N
30.0 ft2
1 ft 8 in
0 ft 7 in
Drapes/blinds
Exterior 1
18
N
30
Vinyl Low-E Single Yes
0.3
0.28
N
16.7 ft2
1 ft 8 in
0 ft 7 in
None
None
10/17)201912:14 PM EnergyGaugela USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHFCKI LGT RFPnPT
GARAGE
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. WaII Height Exposed Wall Insulation
1
462 ft2
462 ft'
.v, 26,ft; :,. 8ft 11
INFILTRATION
# Scope
Method
SLA
CFM50 ELA EgLA ACH ACH50
1 Wholehouse
Proposed ACH(50)
.000401
2429.8 133.39 250.87 .1459 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COP:1 27 kBtwhr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER: 16 41 kBtwhr 1230 elm 0.8 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF " "" "Cap Use SetPnt Conservation
1
Electric None
Garage
0.98 ,; .�' ' 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model 9- Collector Model # Area Volume
FEF
None
None
q ' , �, . " ft2
DUCTS
V #
--- Supply----
Location R-Value Area
---- Return --- - ' _ Air CFM 25 CFN25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
Attic 6 175 ffz
Attic
18 ft2 Default Leakage "' Atic' ' (Defauft) c(Default) c
1 1
10/17201912:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes20413C 6th Edition (2017) Compliant Software
Page 6 of 7
TEMPERATURES
Programable��xThermostat:
C[[eilling Fans:
Hang
:XJan]]N
J�
Feb[`X]J
Feb
jMar]
MaY
[[XJ]
Jun
4X]J
Jul
[[X]]
Aug
4X]J
�nl
jjOct
OctOctt
Nov[X]J
Dec
Venting
l 1 Jan l
1 Feb
lXl Mar
lxl Pr
f
1
,
l; l Jun `
l 1 Jul
l 1 Aug
l
1 SSepe
Sep
Nov
l 1
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
.5
6
7
8
9
10
11
12
Cooling(WD)
AM
78
78
78
78 '"
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78
78,
78
78'
78
80
80
80
80
PM
80
80
80
80
78 `•
78
78
78
78
78
78
78
Heating(WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68,
68
68
68
68
68
Heaffng(WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
MASS,
Mass Type
Area
:Thickness-•
.FumitureFraction
Space
Default(8 lbs/sq.ft.
0ft2
•^_.0It
0.3
MASTERBEDR00
Defau@(8 lbs/sq.ft.
ft2
It,
0.3
WIC
Default(8 lbs/sq.ft.
ft2
it
0.3
MASTER BATH
Default(81bs/sq.ft.
- ft2
ft
0.3
TOILET
Default(8 lbs/sq.ft.
'ft2
ft! _
0.3
LINEN
DefauH(81bs/sq.ft.
112
ft
0.3
FOYER
Default(8lbs/sq.ft.
IF
_ Its '
0.3
OFFICE
Default(8 lbs/sq.ft.
ft2
ft•
0.3
LIVING ROOM
Default(8 lbs/sq.ft.
ft2
ft �. �
0.3
KITCHEN
Default(81bs/sq.ft.
I?
ft
„'.0.3
HALLWAY
- Default(Blbs/sq.ft.
ft2
It
' • 0.3
UTILITY ROOM
Default(8 lbs/sq.ft.
f12
it
0.3
CLST2
Default(81bs/sq.ft.
ft2
it%^
0.3
BEDROOM2
Defauft(8lbs/sq.ft.
f12
If
0.3
BATH 2
Default(8 lbs/sq.ft.
fr2
ft.:•`+, •-
- 0.3
CLST3
Defautt(8 lbs/sq.ft.
ft2
It
0.3
BEDROOM3
Default(81bs/sq.ft.
IF
It
0.3
FAMILYROOM
Default(8 lbs/sq.ft.
ft2
It
0.3
NOOK
Default(8lbs(sq.ft.
- ft2
- It
0.3
CLST
Default(8lbs/sq.ft.
ft2
It;.
0.3
CABANA
rldmdlnl IFc/m F
n ft
.,
n ff -
n 9
!'1FFIRF CI CT
n
10/172019 12:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software
Page 7 of 7
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
2. Single-family or multiple -family
2. Single-family
b) Return ducts R�Q
c) AHU location Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity 41.
a) Split system SEER 16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2308
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-tactor:(weighted average)
7a. 0.531
b) Solar Heat Gain Coefficient (SHGC)
,
7b. 0.240
14. Heating system: Capacity 27.0
C) Area
7c. 409.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
- " "'
c) Electric resistance COP 1.0
a) U-tactor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
81b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
'
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water Pealing system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.98
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
tOBi. 11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 0.0
b) Cross ventilation No
b) Single assembly
11b.
c) Whole house fan No
C) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
I) Programmable thermostat No
*Label required by Section R303.1.3 of the
Florida Building Code; Energy Conservation, if not DEFAULT.
('certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. '
Builder Signature:
Date: 11 /19/19
Address of New Home: 2351 S BROCKSMITH
ROAD
City/FL Zip: PORT ST LUCIE FL
10/172019 12:15:30 PM EnergyGauge®
USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1