HomeMy WebLinkAboutVet windArchitectonic Inc
July 14, 2020
St. Lucie County Building Department
2300 Virginia Ave.
Fort Pierce, FL
Re: Roofing specification prepared for the St. Lucie County Building Department for the
structure located at, 3404 W. Midway Road, Fort Pierce, FL
Manufacturer:
Integrity Metals, LLC
Profiles:
5-V Crimp 24 ga. Steel, FL#29444.4
Code:
FBC 2017; Section R 905.10
Wind Speed:
160MPH; Ultimate Design Wind Speeds
Exposure:
C
Mean Roof Height:
30' Maximum
Pitch:
5 /12 Minimum
Required Design Pressure:
Zone1: -29.1 Zone 2: -48.4 Zone3: -72.6
Maximum Uplift Pressure:
-116 @ 12" o.c.
Fasteners:
#10-15 Woodtite Fasteners @ 12" o.c., with seating washer through
panel rib with %" minimum penetration through plywood
Underlayment:
Tri -built Roof Underlayments, FL# 16048.1, self -adhered
Roof Decking:
Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank
@ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2,
and 4" O.C. thru out zone 3.
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,
and the Manufacturer's recommendations.
;Respectfully submiftei
Mcha .l Seal
ti Y
806 Delaware Avenue Tel: 772 460 7751 Www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1