HomeMy WebLinkAboutRevision; Evaluation Report (MasterRib Panel)EVALUATION REPORT OF UNION CORRUGATING COMPANY `29 GA. MASTERRIB PANEL' OVER WOOD SUPPORTS FLORIDA BUILDING CODE 6Tu EDITION (2017) FLORIDA PRODUCT APPROVAL FL 9557.2-114 PANEL WALLS SIDING Prepared For: Union Corrugating Company 701 S. King St. Fayetteville, NC 28301 Telephone: (910) 483-0479 Fax: (910) 483-1091 Prepared By: Bala Sockalingami Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (2 Pages including cover) Installation Details (I Page) Load Span Table (1 Page) Report No. C2173-2 Date: 8.18.2017 W C.)'4 ~(�� cc 0 < LL �aaI.10 L()0 �W2W� t6110=ca W W � J � H Cl) ,%%%%y0Gl(ALlry�q .. �'. m ' y 62240 No :uj= Of- i. . .'ta FL 9557.2-R4 C2173-2 8.18.2017 Page 2 of 2 Manufacturer: Union Corrugating Company Product Name: MasterRib Panel Panel Description: 36" wide coverage with 3/4" high ribs at 9" o.c. Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Support Description: Nom. 2" x 2" (min) SPF, SYP or DF lumber (Must be designed by others) Design Pressure: +45.35 and -36.2 psf @ support spacing of 48" o.c. (Based on testing) (@ 3 span condition with FS = 2.0) Panel Attachment: #9-15 or #10-14 x 1.5" long wood screws with washers At panel ends @ 3.5"-5.5"-3.5" o.c. across panel width At intermediate @ 9" o.c. across panel width Sidelap Attachment: '/4"-14 x 7/8" long SDS with washer @ 24" o.c. Test Standards: Panel assembly tested in accordance with ASTM E1592-01 `Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference'. Test Equivalency: The test procedures in ASTM E1592-01 comply with test procedures prescribed in ASTM E1592-05(2012). Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1404.5. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. The design pressure for reduced support spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Union Corrugating load span table. This product is not approved for use in the High Velocity Hurricane Zone. Supporting Documents: ASTM E1592 Test Report ENCON Technology Inc. C1514-1 (Test 92 & 3), Reporting Date 9/8/07 INTERIOR SUPPORTS END SUPPORTS LUMBER - (DESIGNED )- BY OTHERS) PANEL FASTENER 3.5'-5.5'-3.5' O.C. SIDELAP FASTENER ® 24' D.G. MASTERRIB �q PANEL ■ y PANEL FASTENER 0 9' O.C. PANEL FASTENER SEE PANEL SIDELAP SIDELAP FASTENER am 9' O.C. �9' O.0DETAIL _ ® 24' O.C. PANEL MAEERR18 EL PANEL FASTENER ® SIDELAP FASTENER 3.5'-5.5'-3.5' O.C. ® 24' O.C. 9 O.C. /— PANEL PANEL TYPICAL PANEL INSTALLATION X-SECTION SIDELAP FASTENER MASTERRIS 1/4'-14 SOS W(fH PANEL WASHER ® 24' O.C. PANEL FASTENER q9-15 OR q10-14 x 1.5" LONG SDS WITH WASHER MAX 48' D.C. (SEE LOAD SPAN TABLE FOR ALLOWABLE LOADS AND SPANS) NON. 2" X 2' (MIN) LUMBER (DESIGNED VIEW BY OTHERS) `NOM. 2' X 2' (MIN) LUMBER (DESIGNED BY OTHERS) PANEL SIDELAP GENERAL NOTES: 1. WALL PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. WALL PANELS SHALL BE 29 GA. (L - 0.013"). EFFECTIVE COVERING WIDTH OF PANEL - 36'. 3. WALL PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE DESIGN LOADS. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL 6. SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 7. PANELS MAY SPAN BETWEEN BOTTOM TO TOP SUPPORTS OR SIDE TO SIDE SUPPORTS. •, 1 UNION CORRUGATING COMPANY MasterRib Wall Panel 36" wide, 29 ga. (min) Steel Panel over Wood Supports Span Condition Loading Type Allowable Load (psi) Support Spacing (ft) 1.50 1.75 2.00 2.25 1 2.50 2.75 3.00 3.50 4.00 Two Span Positive Negative 106.4 84.9 91.2 72.8 79.8 63.7 70.9 56.6 63.9 51.0 58.0 46.3 53.2 42.5 45.6 36.4 36.3 29.0 Three Span Positive Negative 120.9 96.5 103.7 82.7 90.7 72.4 80.6 64.4 72.6 57.9 66.0 52.7 60.5 48.3 51.8 41.4 45.4 36.2 Four or More Spans Positive Negative 116.4 92.9 99.8 79.6 87.3 69.7 77.6 61.9 69.8 55.7 63.5 50.7 58.2 46.5 49.9 39.8 1 42.4 33.8 Notes: 1. Allowable load for each condition is the smallest load calculated based on fastener capacity, panel strength and and deflection limit of L/120. Allowable loads are calculated for minimum 29 ga. panel. 2. The wind load is taken as 0.7 times the "component and cladding" loads for the purpose of determining deflection limit. 3. The panel allowable properties are determined from full scale ASTM E1592 tests at 4' 0" span 4. The panel fasteners are #9-15 or #10-14 x 1.5" long wood screws with washers. Fastener spacing across panel width is 9.0" o.c. in the interior supports and 3.5"-5.5"-3.5" o.c. at panel ends. 5. Sidelap fasteners are 1/4"-14 x 7/8" long self drilling screws with washer at 24" o.c. 6. Wood supports are minimum 2" x 2" lumber. All supports must be designed to resist all loads imposed on the panel. 7. Minimum bearing width of support is 1.5". 8. The panels may span from bottom to top supports or side to side supports. 9. Panels must be installed as per Evaluation Report FL 9557.2 and Union current installation procedure. i� 1216 N Lansing Ave. Suite Tulsa, OK 74106 { 918 492 5992 Bala Sockalingam, Ph.D., P.E. PE 62240