Loading...
HomeMy WebLinkAboutHANSON- Solar PV Plans -COGEN Disconnect Located adjacent to Utility meter Utility Meter 2' Access Pathway R G O N R-1 Inverter Type: Enphase IQ7 # Modules (15) PV Panel: (37)Silfab-SIL-320NL Racking: Iron Ridge Pitch: 24' Total Wattage: 11,840W Roof Type: Comp Shingle Azimuth: 244' Wind Load: 7 to 27 Deg Fastener Type: Use 5/16"Dia 5"Lags O Sheet Index F S-1 Cover Sheet/ Site Plan S-2 Detail E-1 One - Line S-IA Mounting Plan H General Notes: o 0 -Enphase IQ7 Micro Inverters are located on roof behind each module. -First responder access maintained and T T from adjacent roof v -Wire run from array to connection is 40 feet. 3'-31 Godwin Engineering and 51 711 U L Design, LC R-2 Design, l Loop 2' Access Pathway Layout Subject to Change Based on Site Conditions 8378 Pensacola, FL 32526 # Modules (22) D. Chad Godwin, PE Pitch: 24' Chad@godwineng.com Azimuth: 154' Cli-4) System meets the requirements of NFPA 12015 Edition, Chapter 11.12 Install will be done to Manufacturer Spec AGIDC Solar LLC Meets All Editions of Florida Fire Prevention Code 6th Edition Customer Info: 5001 South Florida Ave, Ste 203 Legend ® Chimney Lakeland, FL 33813 ® First responder access Satellite 855-577-7999 1 st Responder Access N 0 Utility Meter o Vent Pipe Represents all Fire Clearance p Bar ara Hanson Date' 7.10.2020EP PV Disconnect including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2015 IRC 1508 Coralbean Ct. Drawn by: GM 2017 FL Residential Code & FBC, 6th Edition (2015 International Residential Code - 2nd Printing Port St. LuCle, FL Checked b modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 34952 Rev #:International Energy Conservation Code, County of Saint Lucie Code, 2014 National Electric Code. Rev Date: Page: S-1 Compass for Aerial TJFO---__T IronRidge XR 100 Rail Solar Module HE 9 HEAD DOLT FLANCE NUT Flashing 5116" x 5" Stainless • , Steel Lag Bolt21 cm�w Ironridge XR-100 Ironridge XR-100 General Notes: Install will be done to Manufacturer Spec - L Feet are secured to roof rafters. 48" O.C. using5/16" x 5" stainless Godwin Engineering and Design, LLC steel Lag bolts. 8378 Foxtail Loop Pensacola, FL 32526 - Subject roof has One layer. D. Chad Godwin, PE - All penetrations are sealed and flashed. Chad@godwineng.com Roof Section Pitch Roof Rafter and Spacing Overhang Notes: ��A� R 1 -R2 5/12 2"x4" @ 24 O.C. 12" Truss AClDC Solar LLC Customer Info: 5001 South Florida Ave, Ste 203 Designed as per ASCE7-10 Inverter Type: Enphase IQ7 Lakeland, FL 33813 PV Panel: (37) Silfab-SIL-320NL 855-577-799 Racking: Iron Ridge Barbara Hanson Date: 7.10.2020 Total Wattage: 11,840W 1508 Coralbean Ct. Drawn by: GM Modules mounted flush to roof Roof Type: Comp Shingle Port St. Lucie, FL Checked by: no higher than 6" above surface Wind Load: 7 to 27 Deg Rev #: 00 g Fastener Type: Use 5/16" Dia 5" Lags 34952 Rev Date: Page: S-2 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN ivR( H TO THE SW17C Enphase Output Ckt Per String swiTCH m E DUAL POWER SUPPLY INVERTER OUTPUT CONNECTION: .OFF'PORMOB To SOURCES:UTILITY GRID AND DO NOT RELOCATE THIS st to DOWN PV srsTEM PV SOLAR ELECTRIC SYSTEM AND REo„w OVERCURRENT DEVICE To Overcurrent Protection Device SHOM HAZkgn `RTHEARRAY. Photovoltaics: AC Max Output Current 15 Figure 690.56(C)(1)(a) Label for PV Systems that AC Max Output Current * 1.25% 18.75 Shut down the array and the conductors leaving the array (37) Silfab-SIL-320NL Enphase Trunk Cable Overcurrent Protection A 20 No. of Current Carrying Cond <4 PHOTOVOLTAIC SYSTEI Inverters: Conductor Gauge AWG 10 EQUIPPED WITH RAPID SHUTDOWN (37) Enphase IQ7 Micro Inverters Enphase Total Output Ckt WARIII Circuits: AC Max Output Current 37 DEDICATED SOV.. AC Max Output Current * 1.25% 46.3 NOT CONNECT ANY OTHER F7 (2) circuits of(11) Modules (1) circuit of(15) Modules Overcurrent Protection(A) 50 NEMA 3R No. of Current Carrying Cond <4 Junction Box Roof Maximum Inverters Per 20A Circuit(16) Conductor Gauge(AWG) 6 #12 AWG THWN for Home runs under 100' Black-Li #10 AWG THWN for Home runs over 100' Red-L2 (1)Line 1 NEC LABEL NOTES: (1)Line 2 Green-Ground 1. THE WARNING SIGN(S)OR LABEL(S)SHALL COMPLY Per Circuit WITH NEC 110.21(B) e AWG THWN 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. (1)EGC 3. LABELS TO BE A MIN LETTER HEIGHT OF 3/8"AND Inside @ least 3/4"Conduit(tbd on site) WARNING PERMANENTLY AFFIXED. ELECTRIC SHOCK HAZARD Meter 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC DO NOT TOUCH TERMINALS REQUIREMENTS OF THE AUTHORITY HAVING TERMINALS ON BOTH THE LINE AND JURISDICTION. LOAD SIDES MAY BE ENERGIZED IN w THE OPEN POSITION O Main Disconnect RATEDAC OUTPUT CURRENT A 200A Main NfOMINALOPERATING ACVOLTAGE V PHOACVDISCONNECTEI L1rieSideTap ARNING:PHOTOVOLTAIC INAL OPERATING VOLTAG AC OUTPUT CUR RENT� POWER .SOURCE Manual Lockable Disconnect 60A Service Rated Fused Disconnect Enphase Combiner Box Neutral to Ground Bond AC Disconnect Godwin Engineering and 50A Fuse (1)-20A Breaker Design LLC Per Circuit 8378 Foxtail Loop Disconnect Located Adjacent to Utility Meta " Pensacola, FL 32526 #6 AWG TH" D. Chad Godwin PE (1)Line 1 #6 AWG THWN , (1)Line 2 (1)Line 1 (1)Neutral (1)Line 2 = Chad@godwineng.com #8(1)EGC (1)Neutral in @ least 3/4"Conduit Typically in @ least 3/4"Conduit Typically In Compliance with NEC 705(D)(2) (1)#8 AWG EGC&GEC Refer to NEC 312.8 for Conditions on taps in switch ACIDC Solar LLC and over current devices Enclosures. If the tatapboxwillions me not 5001 South Florida Ave, Ste 203 met a tap box will System meets the requirements of NFPA 12015 Edition, Chapter 11.12 1 need to be installed. GEC NOTES Customer Info: Lakeland, FL 33813 Including the label below Note: 855-577-7999 -All wiring to meet the 2014 NEC and Provide a grounding electrode system for an In Case of Emergency Callungrounded system per 690.47(C)(3). Date: 7.10.2020 Floridadelectric codes. - GEC must be installed per 250.64 Barbara Hanson ACD C (�O1ar g L Y l LLC C Fl - GEC must be continuous un-spliced or irreversibly spliced from Drawn by: GM 60A Disconnect inverter to existing service ground system or continuous from the 1508 Coralbean Ct. Checked b -Type of conduit to be determined arrays to the existing service ground system. at 8 5 5—5 /�7GEC notarraythegroundPort St. L, Rev #: 00 on site by contractor. an additional ground system must be provided from the arrays to a grounding electrode per 690.47(D) 34952 Rev Date: - GEC must be min#8 AWG and installed in conduit Install will be done to Manufacturer Spec Page: E-1 21 '-411 L L L O L r 81 _611 L L L OL L L L L 24'-711 L L O L 0 _ L L L LL L L L L L 19' 811 L L L L L L L L L L L L L L L L L L L L L L U Q 1 1 '-6" L L L L L L L L L L L LL �T L_ L L L L QL L L L QL OL L QL 52'-9" R- 1 R-2 # Modules (15) # Modules (22) 3'-311 Pitch: 24° Pitch: 24° Azimuth: 244° Azimuth: 1540 5'-711 Plans satisfy zones FBC-1510.7.1 Install will be done to Manufacturer Spec 17' 2 Godwin Engineering and Design, LLC 8378 Foxtail Loop 19 Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com = Max cantilever is 16" as per manufacturer spec. Splice Bar g Max Cantilever = Max Span * (3)=48*(3)=16" ACIDC Solar LLC Flashings 85 Customer Info• 5001 South Florida Ave, Ste 203 UFOs 90 Inverter Type: Enphase IQ7 Lakeland, FL 33813 Sleeves/End Caps 29 PV Panel: (37) Silfab-SIL-320NL 855-577-7999 Combiner 2 Racking: Iron Ridge Barbara Hanson Date: 7.10.2020 Ground Lugs 8 Total Wattage: 11,840W 1508 Coralbean Ct. Drawn by: GM Roof Type: Comp Shingle Port St. Lucie, FL Checked by: Wind Load: 7 to 27 Deg 34952 Rev #: 00 Fastener Type: Use 5/16" Dia 5" Lags Rev Date: Page: S-1 A Electrical Specifications SIL-320 NL mono PERC •.....� ..... . � Test Conditions STC NOCT ..... . ....�.���� Module Power(Pmax) Wp 320 242 • vt=ram p\ Maximum power voltage(Vpmax) V 32.88 29.59 ::fit• \ • Maximum power current(Ipmax) A 9.74 8.18 Open circuit voltage(Voc) V 40.10 37.09 SlLm320 NL Short circuit current(Isc) A 10.32 8.46 Si I Module efficiency % 18.8 17.8 SOLAR Maximums stem voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp 0 to+10 Measurement conditions:STC 1000 W1m2-AM 1.5•Temperature 25•C-NOCT 800 W/mz•AM 1.5•Measurement uncertainty 5 3% Pv L •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by t5%and power by 0 to+10W. _JFBANKAB Temperature Ratings SIL-320 NIL mono PERC AUTOMATED DNraGL Temperature Coefficient Isc 0.064%/°C Temperature Coefficient Voc -0.28_%/'C Temperature Coefficient Pmax -0.36%/°C NOCT(t 2°C) 45'C Operating temperature -40/+85 OC • ' INDUSTRY LEADING WARRANTY 1 NL mono PERC All our products include an industry leading 25-year product workmanship Module weight 18.6 kg t0.2 kg 41 t0.4lbs and 30-year performance warranty. Dimensions(H x L x D) 1700 mm x 1000 mm x 38 mm 66.9 in x 39.4 in x 1.5 in _ Maximum surface load(wind/snow)* 4000 Pa rear load/5400 Pa front load N/m2 83.5/112.8 Ib/ftA2 Hail impact resistance o 25 mm at 83 km/h o 1 in @ 51.6 mph 35+YEARS OF SOLAR I N N OVATI O N 60-Si mono PERC-5 busbar 0-Si mono PERC-5 busbar Leveraging over 35+years of worldwide Cells 158.75 x 158.75 mm 6.25 x 6.25 Inch • experience in the solar industry, Silfab Glass 3.2 mm high transmittance,tempered,DSM 0.126 high transmittance,tempered,DSM is dedicated t0 Superior manufacturing anti-reflective coatin anti-reflective coating_ Cables and connectors(referto installation manual) 1200 mm,o 5.7 mm,MC4 compatible 47.2 in, o 0.22 in, MC4 com atible processes and innovations such as Backsheet High durability,superior hydrolysis resistance,multi-layer dielectric film Bifacial and Back Contact technologies, Frame Anodized Aluminum(Black) to ensure our partners have the latest in Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) solar innovation. junction Box UL 3730 Certified,IP67 rated 'Warranties _X 1 NL mono PERC NORTH AMERICAN QUALITY Module product workmanship warranty 25 ears** Silfab is the leading automated solar Linear power performance guarantee® st 30 ears to z 97%end 1 Year z 90%end 12 year z 82%end 25 Year z 80%end 30thvear o module manufacturer in North America. Certifications , NL mon• PERC ® Utilizing premium quality materials and Product ULc ORD C1703,UL 1703,CEC listed,IEC 62716 Ammonia Corrosion;IEC61701:2011 • strict quality control management to deliver Salt Mist Corrosion Certifed,UL Fire Rating:Type 2 6. the highest efficiency, premium quality PV Factory IS09001:2015 modules 100%made in North America. a..Modules Per Pallet:26 Effvs.Irr Performance SIL-320 NIL 5e Pallets Per Truck:36 20 5e3 Modules Per Truck:936 19 DninW�, S E - - - - - *A Warning.Read the Safety and Installation Manual 25•C N for mounting specifications and before handling, 18 40•C Moue. . 8 installing and operating modules. v 17 55•� E **12 year extendable to 25 years subject to regis- " 16 E E tl tration and conditions outlined under"Warranty'at U 15 " ;0'C s h www.silfabsolar.com. S Third-party generated pan files from Fraunhofer- 0 14 'E E E E E o ' ' ' ' ' ' • ' ' i/ • ' ' ! ! • Institute for Solar Energy Systems ISE are available 2 13 ,, , _ o • •. _ •. _ .• • .• • .• • • •• • • .• for download at:www.silfabsolar.com/downloads 12 EI E a • • �-•. • • • • 11 • I I t I t m • -• • •. .• • - • •' •. •• • • D 200 400 600 80o 1000 1200 E o Irradiance(W/m2) a 0 • • • .D2(2Rm = • x a s�s Imie � D,awings not to scale I'o 37.87(982mm) o •' • •. • • • • • .•• • L 39.37(1..M l Silfab Solar Inc. • • • • -iZ 240 Courtneypark Drive East z • . ,. -. - . .. . i �. Mississauga ON L5T 2y3 Canada • • • • -• • • .. .• :I• S I 1 fa b ��� Tel+1 905-255-2501 1 Fax+1 905-696-0267 ••" "•- - •- : SOLAR info@silfabsolar.com I www.silfabsolar.com 910 ® Silfab Solar Inc. 2029 TOP PERFORMER N 800 Cornwall Ave }rygL Bellingham WA 98225 USA Pv MODULE�V GL b Tel+1360-569-4733 RELIABILITY SCORECARD Data Sheet Enphase Microinverters inrui UAIA(UG) rV/-0u-t-us/r4i-0u-es-ub 11QirLub-1z-z-usirV/1`Lu4-1Z-ts-ub Region:AMERICAS Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 50-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V The high-powered smart grid-ready Max DC short circuit current(module Ise) 15 A 15 A Enphase Overvoltage class DC port II II M Enphase IQ 7 MicroTM and Enphase IQ 7+ MicrOTM DC port backfeed current 0 A 0 A Q 7 and I Q 7 dramatically simplify the installation process while PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak Microinverters Part of the Enphase IQ System,the IQ 7 and Maximum umcontinutput 250VA 295VA Maximum continuous output power 240 VA 290 VA IQ 7+ Microinverters integrate with the Enphase Nominal(L-L)voltage/range' 240 V/ 208 V/ 240 V/ 208 V/ 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy'm, Enphase IQ Battery'm, and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) EnlightenT"" monitoring and analysis software. Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms standards set forth by previous generations and Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed current 0 A 0 A enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 warrantv of UD to 25 vears. Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -400C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2-US&IWPLUS-72.2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-S adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). • Lightweight and simple Adaptors for modules with MC4 or UTX connectors: • Faster installation with improved,lighter two-wire cabling PV2 to MC4:order ECA-S20-S22 � I -PV2 to UTX:order ECA-S20-S25 Built-in rapid shutdown compliant(NEC 2014&2017) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Productive and Reliable Cooling Natural convection-No fans Approved for wet locations Yes • Optimized for high powered 60-cell and 72-cell*modules Pollution degree PD3 • More than a million hours of testing Enclosure Class It double-insulated,corrosion resistant polymeric enclosure • Class II double-insulated enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor • UL listed FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Smart Grid Ready Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break • Complies with advanced grid support,voltage and disconnect required by NEC 690. frequency ride-through requirements Compliance CA Rule 21 (UL 1741-SA) • Remotely updates to respond to changing UL 62109-1,UL1741/IEEE1547.FCC Part 15 Class B, ICES-0003 Class B, rnk11rrcA_"'?o kin in 71-ni U *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at https://en/lenphase.com/en-us/support/module-compatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. '-, E N P H AS E® To learn more about Enphase offerings,visit enphase.com E N P H AS E® To learn more about Enphase offerings,visit enphase.com `/ �./ �l A,P_'t IRON RIDGE XR Rail Family Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. _ XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. Their superior spanning capability requires fewer roof attachments, reducing the number of roof - penetrations and the amount of Installation time. y Qs Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. . . . Rail Span A TT �W"Imlq • Force-Stabilizing Curve 100 Sloped roofs generate both vertical and lateral 120 forces on mounting rails which can cause them None to bend and twist.The curved shape of XR Rails 140 X R 10 X R 100 XR 1000 is simially designed to increase strength in both j directions while resisting the twisting.This unique 160 feature ensures greater security during extreme weather and a longer system lifetime. 100 I 120 10-20 140 160 100 30 160 Compatible with Flat& Pitched Roofs Corrosion-Resistant Materials 100 XR Rails are 1ronRidge offers All XR Rails are made of 6000-series 40 compatible with a range of tilt leg aluminum alloy,then protected with an 160 FlashFoot and �.� options for flat anodized finish.Anodizing prevents surface other pitched roof roof mounting and structural corrosion,while also providing 50-70 160 attachments. applications. a more attractive appearance. + 80-90 160 Q 2019 lronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.14 GODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 I (850)712-4219 I chad@godwineng.com July 13, 2020 To: St. Lucie County Building Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Hanson- Residential PV Roof Mount Installation 1508 Coralbean Ct. Port St. Lucie, FL 34952 Plan Reviewer, This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2017 Florida Building Code 6th Edition, FBC ASCE 7 Min. Design Loads for Buildings &Other Structures Per 2017 FBC,the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V it) - 160mph 3sec gust, Exposure Category- C The PV System consist of the modules,railing, and connection hardware.The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. 1/z"plywood decking and 2"x 4" roof trusses 24" O.C. The roofing,decking,and roof trusses are in good condition.The existing structure will be adequate for supporting the additional PV dead load and wind loads. The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the Ironridge railing and flashings/attachments.The attachments can be attached up to 48"apart.The mounts should be staggered,where possible,to allow distribution of the design loads evenly to the structure.The mounts shall be installed with a min. 5/16"lag screw with minimum 2-5/16"thread length. Please see attached documents and contact me should you have any questions. Sincerely, D. Chad Godwin, PE 81360 Exp. 02/28/2021 BUILDING DESIGN PROPERTIES SYMBOL VALUE UNIT BASIC WIND SPEED V T160�I mph Figure 26.5-1C,page 249a ROOF PITCH e >7 to 27 degrees MEAN ROOF HEIGHT h 15 ft ROOF SETBACK a 4 ft ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE A 1.21 Figure 30.5-1,pg 347 TOPIGRAPHICAL FACTOR Kit 1 Figure 26.8-1,pg 252 EXPOSURE C EFFECTIVE WIND AREA 10 sf ZONE1 ZONE2 ZONES VARIABLE DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT REFERENCE:ASCE 7-10 NET DESIGN WIND PRESSURE(UPLIFT) P-3oE24 -73.4 -108.5 psf Figure 30.5-1,pg 346 NET DESIGN WIND PRESSURE(DOWN) P-30 20.3 20.3 psf Figure 30.5-1,pg 346 NET DESIGN WIND PRESSURE(UP) P°at°p -88.81 -131.29 psf Calculation:P°°,°p=Ax Kux Pnec3o NET DESIGN WIND PRESSURE(DOWN) P°°t down 24.561 24.56 psf Calculation:P°°t d-=Ax K,tx P°°tao DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT DEAD LOAD D 3 3 3 psf SNOW LOAD S 0 0 0 psf DESIGN WIND LOAD W -50.94 -88.81 -131.29 psf ASO DESIGN LOAD(UPLIFT) Pde51g„ -37.13 -66.47 -99.37 psf Calculation:Pd,,ig°=D+SQRT(0.6)W(asd) DOWNFORCE CASE 1 Pd.li:„ 3 3 3 psf Calculation:Pdes;a°=1.0D+1.0S DOWNFORCE CASE 2 Pd.lig 27.56 27.56 27.56 psf Calculation:Pd°s;g°=1.OD+1.OW DOWNFORCE CASE 3 Paella„ 1 21.42 21.42 21.42 psf Calculation:Pdeslan=i.OD+0,75S+0.75W DESIGN FACTORS&CALCULATIONS FOR THE USE OF L-FOOT TO ROOF TRUSS DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT MODULE LENGTH C 5.42 ft MODULE WIDTH B 3.33 ft DESIGN LOAD PER MODULE T -670.9 -1200.9 -1795.27 Ibs Calculation:T=Area*W DISTRIBUTED LOAD(UPLIFT) w -100.64 -180.14 -269.29 plf Calculation:w=T/B*2*Allulls 2rz ill"I r°w DISTRIBUTED LOAD(DOWNFORCE) w 45.94 45.94 45.94 plf Calculation:w=PB/2*Assumes 2raill p11 RAIL SPAN BETWEEN ANCHORS POINTS L 4 4 2 ft POINT LOAD(UPLIFT) R -402.54 -720.55 -538.58 Ibs Calculation:R=PLB/2 POINT LOAD(DOWNFORCE) R 183.75 183.75 91.88 lbs Calculation:R=PLB/2*All-2,,il,pe`r°w L-FOOT CONNECTED BY LAG SCREW TO ROOF TRUSS/RAFTER Specific Gravity,Rafter G 0.55 0.55 0.55 Table 11.2A,NDS 2005,page 68(Southern Pine) Min.Dia.of Lag Screw,5/16 D 0.3125 0.3125 0.3125 In Pullout Value of W 306.87 306.87 306.87 Ibs/in W=1800 G3/2 D314 #of Lag screws 1 1 1 Thread Length Td 2.8 2.8 2.8 In Table L2,NDS 2005 Design Pullout Value per Mount Wt 859.24 859.235 859.235 Wt=W*#of Lags*Td SAFTEY FACTOR SF 2.13 1.19 1.60 Calculation:SF=W,/R(Uplift) iy le o.twWl+.q'r h..e`..�1 4+.N+rrrf6+..S•Oad lov✓.r.,dm*lain*.he r° zmw 'I:.rlm....mlh.g m,n.,u..mr•�.l.N.,hp .o s�s.nlr,p. bncrr.�uc..Ek-Armgmwlw p•agaa.m k3sRrd,� r u.r Z dried F�Mga-W-4-.0 FqK Rear Hip Reof(Y e•V.27 A G.M.Moat I e s?70*) Gal1.ItdoF(7-e 0 s as A I ■dA--jar k.7erf ■ 4A-7-T'MAH-T f -. ■.^--Z-1 J•ra AfQ,L9lOI,Men•s ul.Iri dc'µ'P•y w••l•�•.�`4 r.*1.