Loading...
HomeMy WebLinkAboutDesign pressure calcsNewSouth W I N DOW SOLUTIONS 2526 Okeechobee Blvd, West Palm Beach, FL33409 • 561-712-9000 • CRC1330822 Property Information Owner: Dean & Karyn Dekker Address: 4903 S Header Canal Rd Ft Pierce, FL 34945 Building Information Wind Zone: 170 MPH. Exposure Category: C Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: 11 11 Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure s 1 Int 110 49.25 7 34.5 -37.7 2 Int 73 37.25 7 36.2 -39.4 3 Int 36 37.25 7 37.8 41.0 4 Int 73 36.50 7 36.3 -39.5 5 Int 52 36.50 7 37.1 40.3 6 Int 23.25 30.50 7 37.8 41.0 7 Int 73 49.50 7 35.5 48.7 8 Int 73 37.25 7 36.2 -39.4 9 Int 73 37.25 7 36.2 -39.4 10 Int 36 37.25 7 37.8 41.0 11 Int 24 31.75 7 37.8 -41.0 12 Int 23.25 31.25 7 37.8 -41.0 13 Int 73 36.50 7 36.3 -39.5 Prepared in accordance with: ASCE 7-10. Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1