HomeMy WebLinkAboutCertification for Design Load Compliance- -- Planning &Development Services Department
RE'iv1=
• Building & Code Regulations Division DEC 0 57Permitting
- - - 2300 Virginia Avenue, Fort Pierce, FL34982—(772) 462-155
ST. Lucie Count
Certification for Design Load Compliance
Project Name: IMF lJ��li ���1
Project Address: Fif -2) Glri) t l /CX_ [✓—
Permit #: Occupancy Type:_&e4__Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Sixth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: I X II _III_IV Exposure Category., X C _D
4. Design Wind Velocity 160 mph X ASE LRFD End Zone Width: 6 ft
S. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:+20.0,-31.8 Zone 2:+20.0,-55.3 Zone 3:+20.0,-81.7 Zone 4:+34.7,-37.6 Zone 5:+34.7,-06.5 Garage: +28.5,-34.8
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure?_Yes X Not Applicable Explain Why Not:
Aspect Mo <4:1
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSP Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. II so certify that structural elements depicted on these plans provide adequate resistance to the design
Donald J. Nuelle
Print Name Cert # & Co. Cert Auth.
Nuelle Engineering 52046
11634 SW Rowena Street, Port St. Lucie, FL 34987
Company Name & Address