Loading...
HomeMy WebLinkAboutEnergy CodeJ FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-20 Buildar Name: C'- e- 3 k 4ifo 71 -o/r4x U.V 2 Street: 3621 GROVE CT Permit Office: J* . Lu. Gi ?_ City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: 1 `912- - 011 Z Owner: Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1819.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1617.10 ft2 b. Frame - Wood, Adjacent R=11.0 202.22 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1816.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 1816.00 ft2 6. Conditioned floor area above grade (ft2) 1816 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(255.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 512 a. U-Factor: Dbl, U=0.62 255.17 ft2 SHGC: SHGC=0.26 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 39.0 SEER:16.00 c. U-Factor. NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft2 a. Electric Strip Heat 24.8 COPA.00 SHGC: Area Weighted Average Overhang Depth: 6.072 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems 8. Floor Types (1816.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1816.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 Nona c. N/A R= ft2 15. Credits Patel Glass/Floor Area: 0.141 Total Proposed Modified Loads: 56.77 PASS Total Baseline Loads: 62.35 I hereby certify that the plans rid speci ications covered by Review of the plans and ttE STgl� this calculation are in compliant ith t e Florida nergy specifications covered by this Code. ,( v / calculation indicates compliance the Florida Energy Code. y /+ •••,'-:r;•',;.. °�„ O with n,,,,,; PREPARED BY: DATE: 14/20 Before construction is completed this building will be inspected for compliance with Section 553.908 v 0 O . c I hereby certify that t ' ing, as ned, is in compliance Florida Statutes. with the Florida erg Co Ffl 'f4� OWNERIAGENT: BUILDING OFFICIAL: -- -"'- DATE: DATE: - Compliance requires certifica ion by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in S, �t 2�.�d this project requires an envelope leakage test report with envelope leakage no greater than 7.00 AC 4 4.1.2 CODE COMPLIANCE ST. lLUCIE COUNTY BOCC 2/14/2020 12:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 - FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-20 User 1 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 1816 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 3621 GROVE CT County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1816 17796.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infl ID Finished Cooled Heated 1 Main 1816 17796.8 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatic Main 165.2 ft 1816 ft2 ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rod Solar SA Emitl Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Concrete 2031 ft2 Oft' Medium N 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1816 ft2 N Y CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 1816 ft2 0.1 Wood 2114/2020 12:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below �mt To WaILType R-value Fr In Ft In kea R-Vnlup E ction-Absor_Gracl° 1 N Exterior Concrete Block - Ext Insul Main 4.1 58 2 9 4 542.9 ft- 0 0 0.3 0 -2 E Exterior Concrete Block - Ext Insul Main 4.1 18 6 9 4 172.7 ft' 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insul Main 4.1 53 10 9 4 502.4 ft- 0 0 0.3 0 _ 4 W Exterior Concrete Block - Ext Insul Main 4.1 37 5 10 8 399.1 ft' 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 8 9 4 202.2 ft2 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood Main None .39 2 11 8 23.3 ft- WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 2 ft 0 in 1 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft' 1 ft 0 In 1 ft 0 in None None 3 e 2 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft' 7 ft 0 in 0 ft 2 in None None 4 s 3 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 2 ft 0 in 1 ft 0 in None None 5 s 3 Metal Double (Clear) Yes 0.62 0.26 N 6.5 ft- 2 ft 0 In 1 ft 0 in None None 6 s 3 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft° 2 ft 0 in 1 ft 0 in None None 7 w 4 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft- 2 ft 0 in 1 ft 4 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft' 9 ft 0 in 1 ft 4 in None None 9 W 4 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft- 9 It 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 583 ft' 583 ft- 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000436 2076.3 113.99 214.37 .1638 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 24.82 kBtu/hr 1 sys#1 2/14/2020 12:18 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY rI4FrKI IST RFP(1RT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 39 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62:3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft. DUCTS _ / —Supply— --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 512 ft- Attic 238 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cool' [[ ]] Jan [r[7�]Feb Heatin[X] Jan Feb Mar Mar [ ] A r `f[ [ ] Apr ]Ma [X� Jun r[`X Jul ]May [ ] Jun Jul fX� Au [ ] AuI rJ(� Se [ ]Oct ] Sep [ ] Oct (� Nov pC] Nov (� Dec (X] Dec Venting[( II Jan [ 1 Feb l l X Mar (X) Apr (1 l May (1 Jun ( Jul L [) Aug [ 1 Se [X) Oct [XI Nov (1 Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs/s .ft. 0 ft' Oft 0.3 Main 2/14/2020 12:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 39.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1816 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 24.8 c) Area 7c. 255.2 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-faclor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11cL No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed bawd on installed code compliant features. Builder Signature: Date: Address of New Home: 3621 GROVE CT City/FL Zip: FORT PIERCE, FL 34951 2/14/2020 12:18:12 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1