HomeMy WebLinkAboutConstruction PlansA SOLAR PV SYSTEM IMPROVEMENT FOR0 : FILE COPY WALTER RESIDENCE REVIEW PLAN IMPROVEMENT CONSTRUCTION DOCUMENTS RECEN,ED 000,000 0 Iffjug a w -W DEC O fi 2019 02 Permitting Department a St. Lucie County I PROJECT: I `PLum AT`B OR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL o MECH: DATE: o 0 SYSTEM t wo LLm o t]°° W 0 fY M o J f W N Z Q ryj VICINITY MAP INDEX SHEET DRAWING NAME LJ ' W W CV COVERSHEET o 00 SLRI SOLAR SYSTEM EQUIPMENT LOCATION PLAN DATE 11/21/2019n PVR-SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC DRAWN BY: I JLL SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS CHO BY: 11A § REC.NO.#29127 F l t s'f SCALE AS NOTED¢ \_PROJECT SITELOCATION FOR SOLAR IMPROVEMENT - /r 1R68 WJdaat Cave Drivel: �;-------- APPENDIX -------- DRAWING# E4 HB 1021 NEW PROVISION + LETTER \\\Cvl 2D p , CANADIAN SOLAR 330W MODULE DATA SHEET ` ,S Aj i ENPHASEIQ7+ MICROINVERTER DATA SHEET NA.J 3T of d vi 10 ACE (L/ 13 5 nM /� /11,1"A`-�����, WIND ZONE 3 LOCATION TYP. CANADIAN SOLAR 330W MODULE TYP. APPROXIMATE LOCATION F�'LPOT' PENETRATION TO 2W SYP TRUSS. FLASH PER 2017 FBC. SEE SHEET PVRSS FOR DETAILS. RAIL TYP 2 PLCS PER MODULEARRAY APPROXIMATE LOCATION OF ENPHASE ENVOY Q COMBINER BOX (OR EQUAL) APPROXIMATE LOCATION OF� AC DISCONNECT LOCATED I� OUTSIDE AS SHOWN. SEE SHEET SLR2 FOR DETAILS. APPROXIMATE LOCATION OF EXISTING ELECTRIC METER/MAIN DISTRIBUTION PANEL ROOFTOP JUNCTION BOX APPROXIMATE LOCATION FOR WIRE TRANSITION. SEE SHEET SLR2 RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN SCALE; N.T.S. (35) CANADIAN SOLAR 330W MODULES W/ (35) ENPHASE IQ7+ MICROINVERTERS (18) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (4) 17' XR100 RAIL (8) 14' XR100 RAIL 1p (18) 11' XR100 RAIL (12) XR-100 INTERNAL BONDED SPLICE KITS (7) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER (90) WIRE MANAGEMENT II II. (66) IRONRIDGE L-FEET W SCREW (28) IRONRIDGE UFO SLEEVES (28) IRONRIDGE END CAPS FOR RAILS (84) IRONRIDGE GROUNDING UFO CLAMPS (35) LANDSCAPE OR PORTRAIT ENPHASE ENGAGE CABLE CONNECTORS (3) ENPHASE 6 FT EXTENSION CABLE (3) ENPHASE END CAPS (1) NEMA 3R RATED ROOF MOUNTED JUNCTION BOXES DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. ROOF LAYOUT NOTE: SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND ZONE 3 AREAS. I PROJECT: I DATE 11/21/2019 DRAW N BY: 1LL CHKD BY: JIA REC. N0. # 29127 SCALE AS NOTED 'FJ 111111+Y` 'OWER TABLE: DC -SIDE A k PV MODULE I MANUf CANADM5 MODEL CSIH-33 POWER 330 W& VOC 43.5 VDC ISC 9.65 A VMP 36.0 VDC IMP 9.18 AMP NEC SYSTEM SYSTEM SYSTEM GENERAL PHOTOVOLTAIC 3-LINE DIAGRAM SPECIFIC FLAG t` OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES ZL PRIOR TO THE COMMENCEMENT OF WORK B C 1 ST BRNCH C 2ND BRNC C 3RD BRNCH AC -SIDE 1 12 12 11 INVERTER 94PHASE-107+ EQUIPMENT SHALL BE INSTALLED PER THE 2014 NATIONAL ELECTRICAL CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY. 295 W 3540 W 3540 W 3245 W PEAK POWER 290 W 3480 W 3480 W 3190 W CONT. POWER LISTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC �110.3(B). ENPHASE MICROINIVERTER SYSTEM IS RAPID SHUTDOWN COMPLIANT PER NEC 690.12. 240 VAC 240 VAC 240 VAC 240 VAC VOLTAGE 1.21 A 14.52 A 14.52 A 13.31 A CURRENT 60 HZ 60 HZ 60 HZ 60 HZ FREQUENCY TO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY q�NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A TOTAL VOLTAGE DROP OF 2%OR LESS PER INVERTER MANUFACTURER. SPECTRUM AMI.5, IRRADIANCE @ 1000 W/M2 5 LABEL DEVICE PER NEC 690.14(C)(2), AND SECURE PER NEC 690.7(D). LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. �U �`�Q�f � J 0 0 0 <� 3 PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR EQUAL TO 120%OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12. ENPHASE Q CABLE SHALL BE KEPT q" ABOVE ROOF SURFACE MINIMUM ISNOTREQUIRED PER ENPHASE TUBER. SYSTEM DOES NOT CONTAIN OT REQUIRE EQUIPMENT q� MANUFACTURER. 107+MICROINVERTER DOES NOT REQUIRE EQUIPMENT BONDING FOR GROUNDING. SEE MANUFACTURER'S INSTALIATION MANUAL FORDETAILS. I PROJECT: I d 0 w O W V V Q w U 0 0 W <Y O w �vid o� w Q °1'E tr M W J — a W y V U OOd. rL d w DATE 11/21/2019 DRAWN BY: JLL CHKD BY: JIA REC. NO. # 29127 SCALE AB NOTED dsl99111 _ 1 T 4 Nol + odT 1 kk4 ll 1'pTF (�F ° ��O JO R AN10PE14/E 1 uawlk / \ NAB ��\\ /1E J1 PHOTOVOLTAIC MODULE GENERAL NOTES: 1. APPLICABLE CODE 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) &ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7" TO A MAXIMUM 27" (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE RESIDENTIAL ROOF SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. FIELD VERIFY. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND 15 THE RESPONSIBIUTY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAI, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL 39" X 65" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. ALL SOLAR RMUNG AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) OR LOCAL GOVERNING CODE. ULTIMATE WIND ZONE 1 MAX WIND ZONE 2 MAX WIND ZONE 3 MAX EMBED. WIND SPEED SPAN, MAX SPAN, MAX SPAN, MAX DEPTH Vw,(MPH) CANTILEVER CANTILEVER" CANTILEVER" REQ. 160 6'-0" O.C., 2'-4" O.C. 4'-0" O.C., Y-7" O.0 2'-0" O.C., 9" O.C. 3" - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "D", RISK CATEGORY II , ENCLOSED BUILDING AND I, < 60'-0" PER ASCE 7.10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER 5TRUCTURES" AND 2017 F.B.C. UIRD • LAG BOLT DEPTH REQED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. "3RD RAIL IS REQUIREPER ROW OR COLUMN FOR SPECIFIED ROOF ZONE 'a DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2017 FLORIDA RESIDENTIAL CODE 6TH EDITION i O I GABLE END BUILDING 1 HIP END BUILDING ROOF ROOF WIND AREA ZONES WIND AREA ZONES I � I i 0 TYPICAL PHOTOVOLTAIC -ARRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN r2� SCALE: 3 "=1' 0" CUT OUT OR REMOVE TILE TO INSTALL PER MODULE ARRAY AND BE CONNECTED LESS THAN 25% OF MODULE LENGTH IN ROOF ZONE 1. IN ROOF ZONES 2 & 3 THREE f31 RAILS ARE REQUIRED PER MODULE ARRAY. USE ANTI -SEIZE AND TIGHTEN TO TORQUE]�vQ. PHOTOVOLTAIC PER MANUF. INSTRUCTIONS OtN, MODULE TYP. REFER TO SCHEDULE FOR ��CY REQUIRED EMBEDMENT DEPTH pOV� LABELED "X" IN THIS DETAIL. &ry5°j° IRONRIDGE XR1000 ALUM. L-FOOT OR XR100 ALUM. FASTENED TO RAIL W/ SOLAR RAIL TYP. BONDING BOLT & NUT � �ROOFFLAT FIING TYP. TILE WOOD 12" ALUMINUM INTERNAL SPLICE BAR (USE WHEN 1 SPLICE AT MID -SPAN W/ j G (4) #12-14X8' ST STL SELF TAPPING SCREWS TYP IRONRIDGE XR1000 OR XR100 #12.14 8q' ST STL SELF TAPPING ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE TYPICAL SOLAR RAIL BEAM SPLICE DETAIL PV MODULE FRAME IRONRIDGE UFO CLAMP SHEATHING IRONRIDGE RAIL WOOD ROOF IRONRIDGE - - TRUSS TYP. UFO CLAMP IRONRIDGE ALUMINUM STANDOFF STOPPER SLEEVE 'g ASSEMBLY TYP. PV MODULE `- (2) f-6 ST STL LAG BOLT. SEE SCH FOR EMBED DEPTH REQ. TYP EACH STANDOFF TYPICAL PV L-FOOT CONNECTION DETAIL �1 SCALE: 1 ;"=1' 0" FRAME 3" 8 MID CLAMP - PLAN END CLAMP - PLAN MID CLAMP - SIDE END CLAMP - SIDE END & MID CLAMP CONNECTION DETAILS IRONRIDGE UFO CLAMP PV MODULE FRAME IRONRIDGE RAIL DATE 11-25-2019 DRAWN BY: JLL IRONRIDGE CHKD BY: JLA UFO CLAMP RECORD #: 1 29127 PV MODULE SCALE AS NOTED FRAME IRONRIDGE DRAWING# STOPPER SLEEVE IRONRIDGE RAIL PVR1 • _,JLS dnr - ro•ice i yy 0`e3/ qy§g .. Tlir .OUT SO AN y "' n L6 w7/JILT 1111 LTY\