PV Module Product Datasheet
ENGINEERING DRAWING (mm) Rear View Frame Cross Section A -A Hole ELECTRICAL DATA I STC* CS1H 320MS 325MS 330MS 335MS Nominal Max. Power (Pmax) 320 W 325 W 330 W 335 W Opt. Operating Voltage (Vmp) 35.6 V 35.8 V 36.0 V 36.2 V Opt. Operating Current (Imp) 9.00 A 9.09 A 9.18 A 9.27 A Open Circuit Voltage (Voc) 43.3 V 43.4 V 43.5 V 43.6 V Short Circuit Current (Isc) 9.51 A 9.58 A 9.65 A 9.73 A Module Efficiency 18.98% 19.27% 19.57%19.86% Operating Temperature Max. System Voltage -400C--+8585°C 1500V (IEC) or 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 1703) or CLASS C (IEC 61730) Max. Series Fuse Rating 20 A Application Classification Class Power Tolerance 0-+5 W *Under Standard Test Conditions (STQ of irradlance of 1000 W/m', spectrum AM 1.Saadcelltemperaemeof SC Measurementunceralnty.33%(Pmax). ELECTRICAL DATA I NMOT* CS1H 320MS 325MS 330MS 335MS Nominal Max. Power(Pmax) 239 W 242 W 246 W 250 W Opt. Operating Voltage (Vmp) 32.5 V 32.7 V 32.8 V 33.0 V Opt. Operating Current (Imp) 7.35 A 7.42 A 7.50 A 7.57 A Open Circuit Voltage (Voc) 40.7 V 40.8 V 40.9 V 41.0 V Short Circuit Current (Isc) 7.67 A 7.73 A 7.78 A 7.84A * Under Nominal Module Operating Temperature (NMOT), Irradiance of 800 W/m' spectrum AM 1.5, ambient temperature (3-C, Wind speed 1 Ms. The specifications and key features contained in this datasheet may deWate slightly from our actual products due to the ongoing innovation and product enhancement Canadian Solar Inc. reserves the right to make necessary adjustment to the information described herein at any time Without further notice. CS1 H-330MS / I-V CURVES 5 10 15 10 Z 30 35 40 45 50 5 10 IS 20 25 30 35 40 45 50 1000W/m' 5•C ■ 000 W/m 25•C ■ 600 W/m' 45•C 400 W/m' 65°C 200 W/m' MECHANICAL DATA Specification Data Cell Type Mono -crystalline Dimensions 1700 x992 x35 mm (66.9 x 39.1 It 138 in) Weight 19.2 kg (42.3 lbs) Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy ]-Box IP67, 3 bypass diodes Cable....._. Cable Cable Length (Including Connector) 4.0 mm2 (IEC, 12 A ..WG._(UL) min) Connector T4 series (MC4 series is available) Per Pallet 30 pieces Per Container(40'HQ) 780 pieces TEMPERATURE CHARACTERISTICS SjiwuTication Data Temperature Coefficient(Pri -0.37%/°C Temperature Coefficient (Voc) -0.29%/1C Temperature Coefficient (Isc) 0.05%/1C Nominal Module Operating Temperature 42±3 °C PARTNER SECTION CANADIAN SOLAR INC. Canadian Solar MSS (Australia) Ply Ltd., 44 Stephenson St, Cremorne VIC 3121, Australia su ort@canadlansolar com w canadlansolar com/au pp December 201 B. All rights reserved, PV Module Product Datasheet V5.571 AU `Manufactured and assembled in CTina orThailand. Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters a on To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'° and Enphase IQ 7+ Micro'" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy"', Enphase IQ Battery'", and the Enphase Enlighten'° monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) -The IQ 7+ Micro is required to support 72-cell modules. EN PHASE. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA (DC) IQ7-60-2-US/I07-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used,module pairings' 235 W 3500+ 235 W-440'W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules tt Mawmumunput DC voltage V 60 V Peak power tracking voltage _48 27V-37V 27V-45V Operating.range y �� 16V48V y"�� 16V 60V Min/Max start voltage __....__. �.___..___..._,... _.._.. 22 V / 48 V ___.,_._.._.____.__._ 22 V / 60 V Max'DC short circuitcurrent (module Ise 15A 15A _ y Overvoltage class DC port II II fc port backfeed current. 0 A O A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Maximum continuous output power �NominaC(L L)voltage/range' 240V/ 208V/ 240-V/ 208 V/ 211 264 V 183 229 V 211-264 V 183 229 V I Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) __.. _,_. _.__e.. 1.21 A (240 V) 1.39 A (208 V) L Norrina(frequency - 60 Hz- - 60 Hz Extended frequency range 47-68 Hz 47-68 Hz ..____...,�_d._..__....... AC'sho_rt cncuit fault current over 3 cycles . _.-.-___ ... 5 8 Arms 5 8 Arms ) Maximum units per 20 A (L L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) iOvervoltage class AC port _. _�_s____._.,_:_ III _ AC port hackfeed current O A O A I Power factor setting 10 _ Power factor (adjustable) _ _ 0,85 leading.. ,. ^1-0. 0.85 lagging 0.85 leading... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V :. Peak efficiency %. 97.6 %� 97.5% 973 % .W_ _._._........__.__..____'97.6 CEC weiahted efficiency 97.0 % �_... _ 4i to 100%(condensing) _ _ >&IQ7PLUS 72211S) MC4(orAmphenohH4 UTX with addltiopalQ pCC S'adapter)_" J ) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2(MC4intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 Dimensions (WxHzD). 212 mm x 175:mm z 30 2.mm (without bracket) ) Weight 1.08 kg (2.3816s) 'Goofing �.._. ,Natural convection Nofsris Approved forwet locations Yes �Pollunondegree PD3 Enclosure Class II double -insulated, corrosion resistant polymeric enclosure I Enyirpnmental category/UV exposure rating.__ NEMA Type S/outdoor __ FEATURES disconnect required UL iten monitoring options. of an Enphase IQ Envoy. beenaevaluated`an'd approved by UL for use asdhe load Break FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1,No enforced DC/AC ratio. Seethe compatibilitycalculator at ht s,//e phasecom/en-us/sunnort/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com v EN P H AS E. © 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19