Loading...
HomeMy WebLinkAboutConstruction PlansHELIOCOL COLLECTOR - CONLmETE TILE - TILE ADHESIVE GENERAL NOTES; 1. APPLICABLE CODE: 2017 FLORIDA BUILDING CODE (6TH EDITION) & ASCE-7-10 MINIMUM DESIGN .DADS FOR BUILDING AND OTHER STRUCTURES. 2. PLANS ARE IN ACCORDANCE WITH 2O17 F.B.C. (6TH EDITION) AND PER MIAMI DADE NOA 15-1201.04. 3. POLYPRO ROOF ADHESIVE SHALL BE APPLIED IN COMPLIANCE WITH THE COMPONENT APPLICATION SECTION AND THE CORRESPONDING PLACEMENT DETAILS NOTED IN THE NOA APPROVAL DOCUMENT AND THE 3M/POLYFOAM POLYPRO ROOF TILE ADHESIVE OPERATING INSTRUCTION AND MANUAL BOOKLET. 4. TILE ROOF INSTALLATION AND UNDERLAYMENT SHALL COMPLY WITH LATEST FLORIDA BUILDING CODE AND ROOFING APPLICATION STANDARD RAS 120. 5.3M/POLYFOAM POLYPRO ROOF ADHESIVE COMPLIES WITH THE FOLLOWING CODES: 2014 FLORIDA BUILDING CODE (STH ED), SOUTH FLORIDA BUILDING CODE BROWARD COUNTY-1999, MIAMI DADE NOA 15-1201.04 6. LOCATION OF COLLECTORS WITH 3M/POLYFOAM ADHESIVE 15 NOT TO BE INSTALLED IN WIND ZONE 3. 7. CONNECTIONS AND SPECS PER THIS DRAWING MAY BE USED FOR ALL HELIOCOL COLLECTORS TO RESIST WIND LOADS AS OUTLINED IN 2017 FBC, CHAPTER 16 FOR UP TO 175 MPH, EXPOSURES W OR "C" WIND VELOCITY PER REQUIREMENTS STATED IN ASCE7-10. 3M/POLYFOAM POLYPRO -NOA SPECIFIC NOTES; POLYPRO ROOF TILE ADHESIVE MUST BE APPLIED TO AN UNDERLAYMENT INSTALLED IN COMPLIANCE WITH APPLICATION INSTRUCTIONS DETAILED IN THE FOLLOWING LATEST DOCUMENTS: FRSA/ROOF TILE INSTITUTE ADHESIVE SET TILE SPECIFICATION. 3M/POLYFOAM ADHESIVE IS UL CLASSIFIED AS AN ADHESIVE MIAMI-DADE NOA 15-1201.04, EXPIRES 1103/2021. LIMITATIONS OF MIAMI-DADE NOA FOR SPECIFIED TILE PROFILE -ADHESIVE BELOW: 1) FOR ADHESIVE SET TILE APPLICATIONS, A STATIC FIELD UPLIFT TEST IN ACCORDANCE WITH TAS 106 MAY BE REQUIRED, REFER TO APPLICABLE BUILDING CODE. 2) APPLICANT SHALL RETAIN THE SERVICES FOR A MIAMI-DADE COUNTY CERTIFIED LABORATORY TO PERFORM QUARTERLY TEST IN ACCORDANCE WITH TAS 112, APPENDIX'A'. SUCH TESTING SHALL BE SUBMITTED TO THE BUILDING CODE COMPLIANCE OFFICE FOR REVIEW. 3) MINIMUM UNDERLAYMENT SHALL BE IN COMPLIANCE WITH THE APPLICABLE ROOFING APPLICATIONS STANDARDS LISTED SECTION 4.1 HEREIN. 4) THIS ACCEPTANCE IS FOR WOOD DECK APPLICATIONS. MINIMUM DECK REQUIREMENTS SHALL BE IN COMPLIANCE WITH APPLICABLE BUILDING CODE. TABLE 1: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE PER MIAMI DADE NOA 15-1201.04 CONCRETE ROOF TILE PROFILE PLACEMENT DETAIL MINIMUM SINGLE PADDY WEIGHT (GRAMS) FLAT LOW / HIGH PROFILE #1 AND #2 12 HIGH PROFILE (2 PIECE BARREL) #2 12 FOR HIP AND GABLE ROOFS - PLAN / 1"xq"x2Yz"-16"ALUM. 6063T6 Z-BAR SHAPE WITH (1) 9' DIA. -1 d' LENGTH TAPCON STAGGERED AS SHOWN THIS SHEET HELIOCOL- COLLECTOR TYP 1"xZ"x21/2"-i6"ALUM 6063T6 Z-BAR SHAPE WITH (1) 4' DIA. -14' LENGTH TAPCON STAGGERED AS SHOWN THIS SHEET END CAP TYP. TYPICAL SCALE: =1'-0" HELIOCOL CLAMP CONNECTION (SEE NOTE**) 4'-0" TYP. 24" O.C. PER COLL. TYP. COLLECTOR ARRAY PLAN HELIOCOL CLAM - (2MINIMUM)TYP. HELIOCOL CLAMPS (2 MINIMUM) TYP. ** CLAMP CONNECTION NOTE: 1. WHEN CLAMP FALLS OVER TILE: USE (1) a" DIA. -14' LENGTH TAPCON THRU Z-BAR INTO TILE. 2. WHEN CLAMP FALLS OVER VALLEY: USE (1) q" DIA. -1" LENGTH ST. STL. BOLT - WASHER- NUTTHRU Z-BAR (2) #6 HEX SCREWS " LENGTH TYP 1" x i" x 2 %" - 16' ALUM. CLAMP 6063T6 Z-BAR SHAPE TYP CONNECTION TOP & BOTTOM OF SEE NOTE ** COLLECTOR WITH (1)" DIA. -1 q" LENGTH TAPCON STAGGERED 12" O.C. (SEE Z-BAR DETAIL) FLAT CONC. TILE TYP. APPLY 3M/POLYPRO ROOF TILE #2 S.Y.P. ADHESIVE, OR EQUAL, TO ADHER WOOD ROOF BOTTOM SIDE OF TILE HELIOCOL TRUSS TYP. CLAMP IS ABOVE TO PLUS ALL WOOD TILES AROUND IT (5 MIN.) SHEATHING TYPICAL FLAT / LOW PROFILE CONCRETE TILE ADHESIVE TOP & BOTTOM CONNECTION DETAIL%TN), SCALE: 1"=V-0" HC-6 I"x?"x2Y2"-116"ALUM. 6063T6 Z-BAR SHAPE TYP TOP & BOTTOM OF COLLECTOR WITH (1) 41" DIA. -14" LENGTH TAPCON STAGGERED 12" O.C. (SEE Z-BAR DETAIL) RECEIVED DEC 0 g 2019 Permitting Department St. Lucie County �?f - 0/2n ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR CbfirNCE REVIEWED BY DATE PLANS AND PERMI MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE 1" x Z' x 2 Y2" -16' ALUM. 6063T6 Z-BAR SHAPE (30" MIN. SECTIONS) FASTENED WITH (1) 4' DIA. -14" LENGTH TAPCON 12" O.C. (2) #6 HEX SCREWS 4' LENGTH TYP CLAMP CONNECTION - SEE NOTE ** , HIGH CONC. TILE TYP. 1,� 22 I„ r-ICq 32" TYPICAL Z-BAR DETAIL SCALE: 1 g°=1'-0" 1" x 1" x 21/2" - ifi' ALUM. 6063T6 Z-BAR SHAPE TYP. z _e SPACED 2'-0" O.C. TYP. 4" DIA. 0" LENGTH TAPCON STAGGERED 12" O.C. TYP. z 0 w LD N 111 —APPLY 3M/POLYPRO ROOF TILE �N E S.Y.P. ADHESIVE, OR EQUAL, TO ADHERE r02TROOD TOO F BOTTOM SIDE OF TILE HELIOCOL L SS CLAMP IS ABOVE TO PLUS ALL WOOD SHEATHING TILES AROUND IT (5 MIN.) TYPICAL Z-BAR - HELIO(m_ TYPICAL HIGH PROFILE CONCRETE TILE CLAMP CONNECTION o� ADHESIVE TOP & BOTTOM CONNECTION DETAIL SCALE: 1"=1'-0" DETAIL SCALE: 1/2"=1 I�uTUIxMr, �w z x¢ �z as U z0 LU C2 �:2 7D S 0 00 LU � N W JJ UU� C1 J W ¢ U UwG W E3SUDn.a DATE 7-19-17 DRAWN BY: ]AT CHKD BY: ]AT REC. NO. # 29127 SCALE I AS NOTED MAY 0 9 2019