AQVST LOT 8_E200 REV 3 (2019-10-16)-pdf
PNL AMPS VOLTAGE CKTS WIRE PHASE A 150 1201240 42 3 1 CIR# WIRE POLE AMPS SERVING KW CIR# WIRE POLE AMPS SERVING KW 1 6 2 50 AHU #1 5.0 2 6 2 50 ACCU #1 - 3 4 5 10 2 30 WATER HEATER 4.5 6 6 2 50 OVENS 5.4 7 8 9 6 2 50 ACCU #3 - 10 6 2 60 AHU #3 10.0 11 12 13 12 1 20 COOKTOP HOOD 1.5 14 1 12 1 1 20 GARAGE DR OPENER 1.5 15 1 20 SMALL APPLIANCE #1 1.5 16 12 1 20 BATH GFI'S #1 1.5 17 SPACE 18 12 1 20 CEN VAC 1.2 19 14 1 1 1 15 1 GEN'L LIGHTING 20 14 1 1 15 GEN'L LIGHTING •• 21 14 1 15 GEN'L LIGHTING 22 14 1 15 GEN'L LIGHTING " 23 14 1 15 GEN'L LIGHTING '" 24 14 1 15 GEN'L LIGHTING 25 14 1 15 GEN'L LIGHTING 26 14 1 15 GEN'L LIGHTING 27 14 1 15 GEN'L LIGHTING 28 14 1 15 GEN'L LIGHTING " 29 14 1 15 GEN'L LIGHTING 30 14 1 15 GEN'L LIGHTING 31 14 1 15 GEN'L LIGHTING 321 14 1 1 15 GEN'L LIGHTING •• 33 SPACE 34 SPACE 35 1 1 1 136 37 38 39 40 41 42 PANEL W LOAD CALCULATIONS 1st 10.0 KW@100% 10.0 LARGEST OF: HEATING @ 65% 9.8 COOLING @ 100 REMAINING KW @ 40% 5.9 TOTAL KW 25.7 " GEN. L'TING (2,519 SF @ 3W/SF) 7.6 PANEL A TOTAL KW = 39.7 25,700 W. = 107.1 Amps 240 V. PNL AMPS VOLTAGE CKTS WIRE PHASE B 150 1201240 42 3 1 CIR# WIRE POLE AMPS SERVING KW CIR# WIRE POLE AMPS SERVING KW 6 2 60 AHU #2 10.0 10 2 30 ELEVATOR 3.0 3 4 5 6 2 60 ACCU #2 - 6 12 2 20 DW & DISP #1 2.2 7 8 6 2 50 COOKTOP 5.0 10 2 30 DRYER 4.5 9 12 13 12 1 20 WASHER 1.2 14 12 1 20 BATH GFI'S #2 1.5 15 12 1 20 RECIRCULATING PUMP 1.2 16 12 1 20 SMALL APPLIANCE #2 1.5 17 12 1 20 KIT REF 1.5 18 SPACE 19 14 1 15 GEN'L LIGHTING 20 14 1 15 GEN'L LIGHTING " 21 14 1 15 GEN'L LIGHTING 22 14 1 15 GEN'L LIGHTING 23 14 1 15 GEN'L LIGHTING 24 14 1 15 GEN'L LIGHTING 25 14 1 15 GEN'L LIGHTING 26 14 1 15 GEN'L LIGHTING " 27 14 1 15 GEN'L LIGHTING 28 14 1 15 GEN'L LIGHTING 29 14 1 15 GEN'L LIGHTING 30 14 1 15 GEN'L LIGHTING •• 31 14 1 15 GEN'L LIGHTING 32 14 1 15 GEN'L LIGHTING " 33 SPACE 34 SPACE 35 36 37 38 39 40 41 42 PANEL'B' LOAD CALCULATIONS 1st 10.0 KW@100% 10.0 LARGEST OF: HEATING @ 65% 6.5 COOLING @ 100% REMAINING KW @ 40% 7.7 TOTAL KW 24.2 '- GEN. LTING (2,519 SF @ 3W/SF) 7.6 PANEL B TOTAL KW = 39.2 24,200 W. = 100.8 Amps 240 V. PNL AMPS VOLTAGE CKTS WIRE PHASE P (POOL) 60 1201240 12 3 1 CIR# WIRE POLE AMPS SERVING KW CIR# WIRE POLE AMPS SERVING KW 1 8 2 40 POOL PUMP 1.5 2 12 1 20 POOL LIGHTS 0.8 3 4 12 1 20 POOL HEATER IGNITER 0.5 5 SPACE 6 12 1 20 POOL CONTROLLER 0.5 7 8 SPACE 9 10 11 12 ELECTRICAL LEGEND PHONE JACK O ELECTRIC METER WF WALL MOUNTED FIXTURE © DOUBLE CAT 5e CABLE 0 ELECTRIC PANEL CF CEILING MOUNTED FIXTURE ❑V VIDEO OUTLET w/ 2 RG6 CABLES 1694A BETTER) FD DISCONNECT (BELDEN or cv CENTRAL VAC / HOSE OUTLET ® 220 VOLT RECEPTACLE WJ WALL MOUNTED J-BOX UST FA SINGLE OUTLET DUPLEX OUTLET CJ CEILING MOUNTED J-BOX O SMOKE, CARBON MONOXIDE DETECTOR DUPLEX OUTLET - HALF SWITCHED OT RMOSTAT .L 1 GF $ G.F.C.I. PROTECTED OUTLET PCL PULL CORD FIXTURE S SPRINKLER TIMER WPGF $ WEATHER PROOF GFCI OUTLET T O INTERCOM ® DUPLEX FLOOR OUTLET RECESSED ADJUSTABLE FIXTUREkP KEYPAD QUAD OUTLET ® RECESSED LIGHT FIXTURE �Y �J MOTION DETECTOR WALL SWITCH VP ® VAPOR PROOF RECESSED FIXTURE 3-WAY WALL SWITCH FLOURESCENT LIGHT FIXTURE CEILING FAN 4-WAY WALL SWITCH DIMMER WALL SWITCH / FLOOD/SECURITY LIGHTS PUSH BUTTON SWITCH UNDER CABINET FIXTURE RECESSED RISER )mil POOL LIGHT (BY OTHERS) STEP LIGHTING ELECTRICAL NOTES GENERAL: FIXTURES: 1) CONTRACTOR SHALL VERIFY THE LOCATION OF SERVICE AND SHALL 1) PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "J" LOCATE THE METER & PANELS AS REQUIRED. BOXES. 2) ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE. 2) ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED 3) WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER AND AS SELECTED BY OWNER. CONDUCTORS SHALL BE COPPER OF EQUAL AMPACITY. 3) ALL LIGHTING FIXTURES AND FANS TO BE SELECTED & LOCATED BY 4) ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE. OWNER/ARCHITECT/INTERIOR DESIGNER, UNLESS OTHERWISE NOTED. 5) COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO 4) ARCHITECT TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE CONSTRUCTION. APPLICABLE, UNLESS OTHERWISE NOTED. 6) ROMEX MAY BE USED WHERE CONDUIT IS NOT REQUIRED. 5) FLUORESCENT CLOSET LIGHT FIXTURES SHALL HAVE A MINIMUM 7) BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT. CLEARANCE OF 6" AWAY FROM CLOTHING. 8) VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT 6) PREWIRE FOR GARAGE DOOR OPENER SENSOR. MANUFACTURER SPECIFICATIONS. OUTLETS: 9) PROVIDE DISCONNECT SWITCHES OF SIZE AS REQUIRED BY LOADS. 1) ALL COUNTERTOP RECEPTACLES SHALL BE GFCI OUTLETS. 10) PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIP. 2) PROVIDE GFCI BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR AND AT PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER OUTLETS AS SHOWN ON PLANS. MANUFACTURER RECOMMENDATIONS, 3) ALL 125 VOLT 15 AND 20 AMP RECEPTACLES TO BE TAMPER RESISTANT 11) PROVIDE DISCONNECTS FOR POOL PUMP PER N.E.C. 680. POOL PER 2008 NEC 210.52. CONTRACTOR SHALL PROVIDE ELECTRICAL CONTRACTOR WITH ALL LOADS 4) PROVIDE PRE -WIRED TELEPHONE & CABLE T.V. OUTLETS AS SHOWN ON PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR TO MAKE ALL PLAN. PROVIDE OPTIONAL PRE -WIRED HIGHSPEED DATA OUTLETS AS SHOWN CONNECTIONS PER POOL COMPANY DRAWINGS. VERIFY LOCATION OF ALL ON PLANS. (IF APPLICABLE) POOUSPA EQIUPMENT. 5) FOR FLOOR RECEPTACLES, PROVIDE A COVER PLATE AND FLUSH WITH 12) ALL 120 VOLT 15 AND 20 AMP CIRCUITS THAT SERVE FAMILY ROOMS, FLOOR. VERIFY EXACT LOCATION WITH GC/OWNER. PROVIDE 1/2" CONDUIT DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, UNDER SLAB FROM WALL. SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, OR SIMILIAR ROOMS TO BE SMOKE DETECTORS: ARC FAULT CIRCUIT PROTECTED PER 2008 NEC 210.12(B). 1) ALL SMOKE DETECTORS TO HAVE BATTERY BACK UP AND SIGNAL 13) WIRES SMALLER THAN #6 SHALL HAVE THHN INSULATION, #6 & LARGER SIMULTANEOUSLY W/ TEMPORAL SOUND. SHALL HAVE THWN INSULATION. 2) SMOKE DETECTORS TO BE LOCATED MIN 3'-0" FROM: R/A & SUPPLY GRILLS, KITCHENS, BATH ROOMS. GENERATOR NOTES: 3) SMOKE DETECTORS TO BE COMBINATION TYPE CARBON MONOXIDE ALARN 1. THE EXACT LOCATION OF THE GENERATOR TO BE DETERMINED BY & SMOKE DETECTOR. OWNER/ARCHITECT PRIOR TO ANY CONSTRUCTION. ELEVATOR NOTES: 2. GENERATOR SHALL BE LOCATED MINIMUM OF 10 FEET AWAY FROM ALL 1. ELEVATOR SHALL MEET NEC 620 22-23; VERIFY LOCATION AND OPERABLE WINDOWS AND DOORS, INCLUDING THOSE OF THE NEIGHBORS. ELECTRICAL REQUIREMENTS OF ELEVATOR EQUIPMENT WITH MFG SPECS 3. THE GENERATOR EXHAUST SHALL NOT DISCHARGE INTO THE ADJACENT PRIOR TO CONSTRUCTION. PROPERTY. 2. IF THERE IS AN ELEVATOR PIT LOCATED BELOW, PROVIDE WITH FLOAT SWITCH SENSOR; LIGHT FIXTURE SHALL NOT BE INSTALLED IN ELEVATOR PIT. 3. PROVIDE A LIGHTING FIXTURE WITH RECEPTACLE OUTLET, CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY OPENING PER FMC 306.3.1. PANEL'P' LOAD CALCULATIONS 1st 10.0 KW@100% 3.3 LARGEST OF: 0.0 HEATING @ 65% (6.5 KW) 3,300 W. = 13.8 Amps COOLING @ 100 % (KW) 240 V. REMAINING KW @ 40% TOTAL KW 3.3 ELECTRICAL RISER DIAGRAM ELECTRICAL METER & MAIN DISCONNECT UNDERGROUND TO FP&L TIE-IN LOCATION (1) #2 CU TO 5/8" GROUNDING ROD & TO FOOTER STEAL (1) #2 CU. GND. WIRE TO H2O (2) #6, 1 #6 NEUTRAL, (1) #10 GND IN 1" C. Al ELEVATOR LOBBY 14'-8" x 17'4" REV. 3: ELECTRICAL METER AND PANEL LOCATION + REVISED LIGHTING i r cn'W'^ r a QCITY COMMENTS QCITY COMMENTS CMC CMC 06.26.19 07.16.19 CMC QELEC. REVISIONS 10.15.19 M U W O O V J aw U z C l i Job No. 1802011 ALL IDEAS, DESIGNS, ARRANGEMENTS, & PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, & THE PROPERTY OF THIS OFFICE. & WERE CREATED, EVOLVED. & DEVELOPED FOR USE ON. & IN CONNECTION THE SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS. ARRANGEMENTS, OR PLANS SHALL BE USED BY, OR DISCLOSED TO ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION OF RANDALL E. STDFFT. ARCHITECTS. PA, WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE DIMENSIONS, CONTRACTORS SHALL VERIFY & BE RESPONSIBLE FOR ALL DIMENSIONS & GONDITIONS ON THE JOB, & THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS OF ADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED, 0-8. ALL RIGHTS RESERVED RANDALL STGFFT ARCH TECTS PA. E200