Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LOT 9_E200 REV 3 (2019-10-15) 7_15_20-pdf
CCCLCCCLCCCLCCCLCCCLCCCLCCCLOUTLINE OF POOL ABOVE x32'-2"43'-0" POOL EQUIP/MECHAN. x11'-0"17'-2" STORAGE/ MECHANICAL x23'-8"17'-4" ELEVATOR LOBBY ACCU #3ACCU #2 POOL EQUIP ELEVATOR x20'-4"19'-2" STORAGE DN. UP ELEV. EQUIP. AHU 1 AHU 2 ACCU #1 x28'-0"25'-0" 2 1/2 CAR GARAGE TO SWITICH ABOVE TO LIGHTINGABOVEGF GFGFGF GF GFGF CF CF CF CF CF CF WF WF WF WF GF TO SWITICH ABOVE PC ELEC. PANEL ELEC. METER GENERATOR NOTES: 1. THE EXACT LOCATION OF THE GENERATOR TO BE DETERMINED BY OWNER/ARCHITECT PRIOR TO ANY CONSTRUCTION. 2. GENERATOR SHALL BE LOCATED MINIMUM OF 10 FEET AWAY FROM ALL OPERABLE WINDOWS AND DOORS, INCLUDING THOSE OF THE NEIGHBORS. 3. THE GENERATOR EXHAUST SHALL NOT DISCHARGE INTO THE ADJACENT PROPERTY. ELEVATOR NOTES: 1. ELEVATOR SHALL MEET NEC 620 22-23; VERIFY LOCATION AND ELECTRICAL REQUIREMENTS OF ELEVATOR EQUIPMENT WITH MFG SPECS PRIOR TO CONSTRUCTION. 2. IF THERE IS AN ELEVATOR PIT LOCATED BELOW, PROVIDE WITH FLOAT SWITCH SENSOR; LIGHT FIXTURE SHALL NOT BE INSTALLED IN ELEVATOR PIT. 3. PROVIDE A LIGHTING FIXTURE WITH RECEPTACLE OUTLET, CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY OPENING PER FMC 306.3.1. ELECTRICAL NOTES GENERAL: 1) CONTRACTOR SHALL VERIFY THE LOCATION OF SERVICE AND SHALL LOCATE THE METER & PANELS AS REQUIRED. 2) ALL WIRE SHALL BE THHN COPPER, UNLESS NOTED OTHERWISE. 3) WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE COPPER OF EQUAL AMPACITY. 4) ALL BRANCH CIRCUITS IN RACEWAY OR NON METALLIC SHEATHED CABLE. 5) COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. 6) ROMEX MAY BE USED WHERE CONDUIT IS NOT REQUIRED. 7) BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT. 8) VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER SPECIFICATIONS. 9) PROVIDE DISCONNECT SWITCHES OF SIZE AS REQUIRED BY LOADS. 10) PROVIDE NON-FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIP. AND AT PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER RECOMMENDATIONS. 11) PROVIDE DISCONNECTS FOR POOL PUMP PER N.E.C. 680. POOL CONTRACTOR SHALL PROVIDE ELECTRICAL CONTRACTOR WITH ALL LOADS PRIOR TO INSTALLATION. ELECTRICAL CONTRACTOR TO MAKE ALL CONNECTIONS PER POOL COMPANY DRAWINGS. VERIFY LOCATION OF ALL POOL/SPA EQIUPMENT. 12) ALL 120 VOLT 15 AND 20 AMP CIRCUITS THAT SERVE FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, REC ROOMS, CLOSETS, HALLWAYS, OR SIMILIAR ROOMS TO BE ARC FAULT CIRCUIT PROTECTED PER 2008 NEC 210.12(B). 13) WIRES SMALLER THAN #6 SHALL HAVE THHN INSULATION, #6 & LARGER SHALL HAVE THWN INSULATION. FIXTURES: 1) PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "J" BOXES. 2) ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS SELECTED BY OWNER. 3) ALL LIGHTING FIXTURES AND FANS TO BE SELECTED & LOCATED BY OWNER/ARCHITECT/INTERIOR DESIGNER, UNLESS OTHERWISE NOTED. 4) ARCHITECT TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE APPLICABLE, UNLESS OTHERWISE NOTED. 5) FLUORESCENT CLOSET LIGHT FIXTURES SHALL HAVE A MINIMUM CLEARANCE OF 6" AWAY FROM CLOTHING. 6) PREWIRE FOR GARAGE DOOR OPENER SENSOR. OUTLETS: 1) ALL COUNTERTOP RECEPTACLES SHALL BE GFCI OUTLETS. 2) PROVIDE GFCI BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS SHOWN ON PLANS. 3) ALL 125 VOLT 15 AND 20 AMP RECEPTACLES TO BE TAMPER RESISTANT PER 2008 NEC 210.52. 4) PROVIDE PRE-WIRED TELEPHONE & CABLE T.V. OUTLETS AS SHOWN ON PLAN. PROVIDE OPTIONAL PRE-WIRED HIGHSPEED DATA OUTLETS AS SHOWN ON PLANS. (IF APPLICABLE) 5) FOR FLOOR RECEPTACLES, PROVIDE A COVER PLATE AND FLUSH WITH FLOOR. VERIFY EXACT LOCATION WITH GC/OWNER. PROVIDE 1/2" CONDUIT UNDER SLAB FROM WALL. SMOKE DETECTORS: 1) ALL SMOKE DETECTORS TO HAVE BATTERY BACK UP AND SIGNAL SIMULTANEOUSLY W/ TEMPORAL SOUND. 2) SMOKE DETECTORS TO BE LOCATED MIN 3'-0" FROM: R/A & SUPPLY GRILLS, KITCHENS, BATH ROOMS. 3) SMOKE DETECTORS TO BE COMBINATION TYPE CARBON MONOXIDE ALARM SMOKE DETECTOR. WPGF GF 4-WAY WALL SWITCH DIMMER WALL SWITCH PUSH BUTTON SWITCH WEATHER PROOF GFCI OUTLET G.F.C.I. PROTECTED OUTLET DUPLEX OUTLET - HALF SWITCHED DUPLEX FLOOR OUTLET 3-WAY WALL SWITCH WALL SWITCH D ELECTRIC METER ELECTRIC PANEL 220 VOLT RECEPTACLE DUPLEX OUTLET DISCONNECT PULL CORDFIXTUREPC ELECTRICAL LEGEND SINGLE OUTLET CENTRAL VAC / HOSE OUTLET KEYPAD THERMOSTAT INTERCOM SPRINKLER TIMER MOTION DETECTOR kp ST i T VIDEO OUTLET w/ 2 RG6 CABLES DOUBLE CAT 5e CABLE V CV C5 BELDEN 1694A or BETTER) PHONEJACKPH QUAD OUTLET RECESSED ADJUSTABLE FIXTURE VAPOR PROOF RECESSED FIXTURE UNDER CABINET FIXTURE FLOOD/SECURITY LIGHTS FLOURESCENT LIGHT FIXTURE CEILING MOUNTED J-BOX RECESSED LIGHT FIXTURE WALL MOUNTED J-BOX CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE CEILING FAN EXHAUST FAN VP CJ WF WJ CF RECESSED RISER STEPLIGHTINGPOOLLIGHT (BY OTHERS) SMOKE + CARBON MONOXIDE DETECTOR LOCATION TO FP&L TIE-IN ELECTRICAL RISER DIAGRAM METER 1) #2 CU TO 5/8" GROUNDING ROD TO FOOTER STEAL 1) #2 CU. GND. WIRE TO H2O 150AMP 150AMP 150A PANEL B 40 CKTS M.L.O. A B ELECTRICAL METER & MAIN DISCONNECT UNDERGROUND A.I.C. 10,000 A.I.C. 10,000 POOL PANEL 60 AMP M.L.O. 150A PANEL A 40 CKTS M.L.O. 2) #6, 1 #6 NEUTRAL, 1) #10 GND IN 1" C. 3) #2/0 CU 1) #6 IN 2" C. SERVING 2 AHU #1650 1 3 SERVING 2 4 POLEWIREAMPSCIR #POLEWIREAMPSCIR # 120/240150A VOLTAGEAMPSPNL 42 CKTS 3 WIRE 1 PHASE 2 ACCU #1650 KW 5.0 KW 5 7 2OVENS650 5.4 1 COOKTOPHOOD20 9 1 GARAGE DROPENER1220 11 1 GEN'LLIGHTING1415 13 1 GEN'LLIGHTING1415 15 17 19 21 23 25 27 31 33 29 35 37 39 41 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 1 BATH GFI'S #11220 38 1.5 SPACE 40 42 GEN. L'TING (2,483 SF @ 3W/SF) PANEL A TOTAL KW =39.6 7.5 PANEL 'A' LOAD CALCULATIONS 25,700 W. 240 V. 107.1 Amps 1st 10.0 KW @ 100% LARGEST OF: HEATING @ 65% COOLING @ 100% REMAINING KW @ 40% TOTAL KW 10.0 9.8 5.9 25.7 SERVING 2ELEVATOR1030 1 3 SERVING 2 4 POLEWIREAMPSCIR #POLEWIREAMPSCIR # 120/240150B VOLTAGEAMPSPNL 42 CKTS 3 WIRE 1 PHASE 2 AHU #2660 KW 3.0 KW 10.0 5 7 6 8 9 11 13 15 1 KITREF122017 1.5 1 SMALL APPLIANCE #21220 19 1.5 21 23 25 1.5 1.5 27 29 31 33 35 37 39 41 10 12 14 16 1WASHER1220 18 1.2 20 22 24 26 28 30 32 34 36 38 40 42 GEN. L'TING (2,483 SF @ 3W/SF) PANEL B TOTAL KW =39.1 7.5 PANEL 'B' LOAD CALCULATIONS 24,200 W. 240 V. 100.8 Amps 1st 10.0 KW @ 100% LARGEST OF: HEATING @ 65% COOLING @ 100% REMAINING KW @ 40% TOTAL KW 10.0 6.5 7.7 24.2 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 SMALL APPLIANCE #120 1.5 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 **1 GEN'LLIGHTING1415 ** 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 1 GEN'LLIGHTING1415 **1 GEN'LLIGHTING1415 ** SPACESPACE 1 GEN'LLIGHTING1415 **1 GEN'LLIGHTING1415 ** 1 GEN'LLIGHTING1415 **1 GEN'LLIGHTING1415 ** 2 DW & DISP #11220 2.2 SPACE SPACE 12 1 CENVAC1220 1.2 1 RECIRCULATINGPUMP1220 1.2 1 BATH GFI'S #21220 1.5 SPACE 2 ACCU #2660 - 2 AHU #3660 10.02ACCU #3650 - 2 WATERHEATER1030 4.5 2COOKTOP650 5.0 2DRYER1030 4.5 SERVINGSERVINGPOLEWIREAMPSCIR #POLEWIREAMPSCIR # 120/24060P (POOL) VOLTAGEAMPSPNL 12 CKTS 3 WIRE 1 PHASE KW KW 2 POOLPUMP840 1 1.5 3 5 7 1 POOLLIGHTS12202 0.8 4 6 8 10 12 1 POOL CONTROLLER 9 SPACE 11 SPACE 12 20 0.5 1 POOL HEATERIGNITER1220 0.5 PANEL P TOTAL KW =3.3 PANEL 'P' LOAD CALCULATIONS 1st 10.0 KW @ 100% LARGEST OF: HEATING @ 65% (6.5 KW) COOLING @ 100% (KW) REMAINING KW @ 40% TOTAL KW 3.3 0.0 3.3 3,300 W. 240 V. 13.8 Amps 04-24-19PERMIT SET1 CITY COMMENTS CMC 06.26.19 ACQUAVISTA LOT #9VENETIAN ADMINISTRATION LLCALL IDEAS, DESIGNS, ARRANGEMENTS, & PLANS INDICATED OR REPRESENTED BY THIS DRAWING ARE OWNED BY, & THE PROPERTY OF THISOFFICE. & WERECREATED, EVOLVED, & DEVELOPEDFOR USE ON, & IN CONNECTIONWITH THE SPECIFIED PROJECT. NONE OF SUCH IDEAS,DESIGNS, ARRANGEMENTS, OR PLANS SHALL BE USED BY,OR DISCLOSEDTO ANY PERSON, FIRM, ORCORPORATION FOR ANYPURPOSE WHATSOEVER WITHOUT THE WRITTENPERMISSION OF RANDALL E. STOFFT, ARCHITECTS, P.A. WRITTENDIMENSIONSON THESE DRAWINGS SHALL HAVE PRECEDENCEOVER SCALEDIMENSIONS. CONTRACTORS SHALL VERIFY & BE RESPONSIBLE FOR ALL DIMENSIONS &CONDITIONS ON THE JOB, & THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONSFROMTHE DIMENSIONSAND CONDITIONS SHOWN BY THESEDRAWINGS. SHOP DETAILSOFADEQUATE SCALE MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION ON ITEMS SO NOTED. © 2018. ALL RIGHTS RESERVED RANDALL STOFFT ARCHITECTS P.A.Job No. 1802011 2 CITYCOMMENTSCMC 07.16.19 3 GARAGE AND ELECTR.CMC 10. 15.19 E200 1/4"= 1'-0"GARAGE/GROUND FL. ELECTRICAL PLAN1 REV. 3: EXTERIOR LANDING AND STEPS AT GARAGE + ADD' L