Loading...
HomeMy WebLinkAboutGenerator Concrete Pad PlanI PAD THICKNESS GENERATOR Y I ISOMETRIC VIEW PADDIMENSIONS:IONS: CONCRETE GENERATOR - F -a - --� GENERATOR UNIT BY x o SEPARATE SUBMITTAL 3 (SEE SCHEDULE FOR N MINIMUM WEIGHT REQUIRED) �- 54" LENGTH PLAN VIEW CONCRETE PAD ROAD MESH ASTER= 3" MIN MACI00 -Z-4" MIN 0 GENERATOR TABLE: RICAST GENERATOR CONCRETE PAD (ON -GRADE APPLICATIONS ONLY) AMERICAST FEDTAXRI0.IIl9U ucROB o9Plmmtm SIN FYAXmAve PaM1Plea. F11lRD TJ. 11LPtt-196L F¢ TAJ61C>Di FILE HVHZ OR NON-HVHZ RISK EXPOSURE (EXP) RISK EXPOSURE(EXP RISK EXPOSURE (EXP COUNTY I C D II C 1 D III,IV D P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.853.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psi 170 MPH 39.09 Psf 47.44 Psf 180 MPH qPSf 43.853.19 Psf MIAMI-DADE 165 MPH 36.83 Psf 11 69 Psf 175 MPH 41.43 Psf 50.28 Psf 18fi MPH 46.856.80 Psf BRAND &MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 30 KW 25.00 " 48.00" 29.00" 387lbs 41.43 Psf EXP C 175 MPH & D 156 MPH Generac 005872 & 005894 14 KW 25.00" 48.00" 29.00" 439lbs 47.44 Psf EXPC 186 MPH &D156 MPH Generac 6459 6461 6462 16 KW 25.00" 48.00" 29.00" 5131bs 47.44 Psf Generac 006721 16 KW 25.00" 48.00" 29.00" 448lbs 47.44 Psf Generac 005873 & 005885 17 KW 25.00" 48.00" 29.00" 4551bs 47.AA Psf Generac 005874 & 005886 17 KW 25.00" 49.00" 29.00" 4211bs 47.44 Psf Generac 005875 & 005887120 KW 25.00" 48.00" 29.00" 4511bs 47.44 Psf Generac 006729 & 006730 20 KW 25.00" 48.00" 29.20" SI616s 47.44 Psf Generac 006551&006552 22 KW 25.00" 48.00" 29.00" 526lbs 47.44 Psf Kohler 14RES&20RES 14-20 KW 26.00" 48.00" 29.00'.' 500lbs 47.44 Psf GE 40323GE & 40324GE 13 KW 35.00" 39.40" 39.00" 540lbs 39.09 PSf EXPC 170 MPH &D156 MPH GE 04038215KW 15 KW 33.00" 48.00" 30.50" 4841bs 43.83 Psf EXPC 180 MPH &D 156 MPH GE 04037817KW 17 KW 33.00" 48.00" 30.50" 484lbs 43.83 Psf GE 40330GE & 40331GE 20 KW 33.00" 48.00" 30.50" 600lbs 43.83 Psf Briggs & Stratton 040243-0 SO KW 31.00" 32.00" 34.00" 430lbs 43.83 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00" 1 31.60" 507lbs 41A3 Psf EXP C 175 MPH & D 156 MPH Briggs & Stratton 040303-1 15 KW 33.75" 49.00" 31.60" 562lbs 43,83 Psf EXP C 180 MPH & D 156 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00" 31.60" 568lbs 44.00 Psf Briggs & Stratton 040305-1 20 KW 33.75 " 49.00" 31.60" 5701bs 44.00 Psf Generac 7035,7036, 7037 16 KW 25.00" 48.00" 19.00" 4061bs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 007038 & 007039 20 KW 25.00" 48.00" 19.00" 4481bs 47.44 Psf Generac 007042&7043 22 KW 25.00" 48.00" 29.00" 466lbs 47.44 Psf GENERATOR MOUNTING CONFIGURATION: GENERATOR GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING SCREWS TO TOR -Q (SEE GENERATOR SPECS), i (SEE CONCRETE PAD SCHEDULE FOR JC = DIMENSIONSWEIGHT SION 4" �32" WIDTH 54" LENGTH SIDE VIEW FRONT VIEW B%* THICK GALVANIZED WASHER& RUBBER VIBRATION PAD ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 TITEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4" FULL EMBED 0 CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. RECENED DEC 0 8 2019 Permitting Department SL Lucie County WIND DESIGN REQUIREMENTS: ®N ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION jjjajjj 2017)) T-G DE SIGN METHOD ULTIMATE DESIGN WIND SPEED Vult=486 mph- - - - - - - - - - NOMINAL DESIGN WIND SPEED Vasd = 144 mph RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= 0.85 ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 Ib/ft2 FORCE COEFFICIENT Of = 1.44 WIND PRESSURE: P = qh G CIF = 56.80 Ib/ft2 (ASD) 1. 2. 3. 4. 5 6: GENERAL NOTES NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE 7. EXCLUDES FINISHES, IF & APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO 9, ANY ADJACENT ANCHORS. S. FOLLOW MANUFACTURER'S INSTALLATION INSTRUMIetrCjf! COUNTY INSTALL ANCHORS. PLAN REVIEW 10. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS fie° SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2"x3"xa/." GALV. STEEL - WASHER RUBBER VIBRATION PAD - CONCRETE PAD - 6,000 PSI X LIGHTWEIGHT CONCRETE PAD CONCRETE MIX I 6,000 PSI LIGHTWEIGHT \ MASTERFIBER MAC 100 CONCRETE MIX & ROAD MESH NOTES: FOAM CORE I. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS BLDG: DATE:/L/7' 11. PLUMB: DATE: 12. f- 2"-t 3. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017). REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED F E Q CA U FOR WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE E N C RTIFlCATION O A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. THE PEOFlC LOAD REQUIREMENTS SHALL DETERMINED IN ACCORDANCE E THEAPPLICABLEBUILDING CODE SHALL BE LESS THAN HEREIN MR ATO NY DESIGN PRESSURE -ASD" CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY SHOWN. DIMENSIONS AND WEIGHT OF UNITS SMALL CONFORM TO SPECIFICATIONS STATED HEREIN. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCF THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND 15 NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OFTHIS SPECIFICATION BY CONTRACTOR, at. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, Is FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RSSPONSIBILDY OF THE INSTAW NG CONTRACTOR. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE MRMTITING CONTRACTOR. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GWEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. E LX HERE: ABOUT THIS DOCUMENT r FNGINEERtERnHED ORIGINALS, VARIATIONS & MORE INFORMATION WI BE FOUND BY J MMNG ENGINEENNGIXPPFSS.CD STORE "YT. OR BY SCIWN WG OR wa,G ME WEB ADORESS FOUND HERE > THIS DOCUMENT NOT VAUD W2MOUT Owwroi ORIGINAL ENGINEER GERTI..ON KMCq/17N61d 0 SHALL REMAIN IN AT. & PRINTED UAL SIGNATURE ON SHEET 1 THIS SHEET DOES NOT YTAIN AN ENGINEER'S y to N oa 1V o �® WM,.,U£ FM NON W V< iLL_ Q. WU" m Z ° M> aLLW AL QLU U#Q O=On-4E� 0G s WWnwwz w CLU VU E.LUWxw W ID O w o sG a a M i �z 3' 000 0555, �aw�� &oa�� 6 U 1 17-3961.1